• 제목/요약/키워드: Magnetic Resonance

검색결과 6,504건 처리시간 0.03초

Undifferentiated Pleomorphic Sarcoma of the Descending Thoracic Aorta Mimicking Pseudoaneurysm with Periaortic Hematoma: a Case Report

  • Kim, Minsu;Bae, Young-A;Byeon, Sun-Ju;Choi, Jung-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.162-166
    • /
    • 2019
  • Undifferentiated pleomorphic sarcoma (UPS) arising from the descending thoracic aorta is a rare type of tumor. To our knowledge, only a few cases have been reported in the literature. We present computed tomography (CT) and magnetic resonance imaging findings of a 43-year-old male patient with undifferentiated pleomorphic sarcoma of the descending thoracic aorta, which showed enhancement on only magnetic resonance imaging (MRI). MRI with contrast enhancement may be useful in differentiating an aortic tumor from atherosclerotic disease.

Cerebral Air Embolism: a Case Report with an Emphasis of its Pathophysiology and MRI Findings

  • Kang, Se Ri;Choi, See Sung;Jeon, Se Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권1호
    • /
    • pp.70-74
    • /
    • 2019
  • Cerebral air embolism (CAE) is a rare complication of various medical procedures. It manifests with symptoms similar to those of typical acute cerebral infarction, however the treatment is quite different. We present a case of arterial CAE that was associated with a disconnected central venous catheter and appeared as punctate dark signal intensities with aliasing artifacts on the susceptibility-weighted filtered phase magnetic resonance image. The susceptibility-weighted filtered phase image can be helpful for diagnosing CAE and the magnetic resonance imaging reflects the pathophysiology of CAE.

Bone Involvement of Diffuse Large B Cell Lymphoma (DLBCL) Showing Unusual Manifestations Mimicking Chronic Osteomyelitis in a 58-Year-Old Man: Case Report and Clinical Application of Diffusion Weighted Magnetic Resonance Imaging

  • Lee, Kyung Ryeol;Maeng, Young Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.270-275
    • /
    • 2019
  • This study presents a case of diffuse large B cell lymphoma (DLBCL) in a 58-year-old man showing unusual manifestations mimicking chronic osteomyelitis. In this case review, we describe the imaging findings of DLBCL which mimics chronic osteomyelitis and review existing reports regarding the differential diagnosis of bone involvement of lymphoma and osteomyelitis through imaging and laboratory findings and diffusion-weighted magnetic resonance imaging (DWI) such as the advanced MRI sequence.

Thermodynamic and Physical Properties of (NH4)2MnCl4·2H2O by Nuclear Magnetic Resonance Relaxation Times

  • Kim, Yoo Young
    • 한국자기공명학회논문지
    • /
    • 제23권2호
    • /
    • pp.40-45
    • /
    • 2019
  • The phase transition temperatures and thermodynamic properties of $(NH_4)_2MnCl_4{\cdot}2H_2O$ grown by the slow evaporation method were studied using differential scanning calorimetry and thermogravimetric analysis. A structural phase transition occurred at temperature $T_{C1}$ (=264 K), whereas the changes at $T_{C2}$ (=460 K) and $T_{C3}$ (=475 K) seemed to be chemical changes caused by thermal decomposition. In addition, the chemical shift and the spin-lattice relaxation time $T_{1{\rho}}$ were investigated using $^1H$ magic-angle spinning nuclear magnetic resonance (MAS NMR), in order to understand the role of $NH_4{^+}$ and $H_2O$. The rise in $T_{1{\rho}}$ with temperature was related to variations in the symmetry of the surrounding $H_2O$ and $NH_4{^+}$.

Principles of Magnetic Resonance Angiography Techniques

  • Shin, Taehoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.209-217
    • /
    • 2021
  • Magnetic resonance angiography (MRA) plays an important role in accurate diagnosis and appropriate treatment planning for patients with arterial disease. Contrast-enhanced (CE) MRA is fast and robust, offering hemodynamic information of arterial flow, but involves the risk of a side effect called nephrogenic systemic fibrosis. Various non-contrast-enhanced (NCE) MRA techniques have been developed by utilizing the fact that arterial blood is moving fast compared to background tissues. NCE MRA is completely free of any safety issues, but has different drawbacks for various approaches. This review article describes basic principles of CE and NCE MRA techniques with a focus on how to generate angiographic image contrast from a pulse sequence perspective. Advantages, pitfalls, and key applications are also discussed for each MRA method.

Cranial Nerve Disorders: Clinical Application of High-Resolution Magnetic Resonance Imaging Techniques

  • Lee, Ji Ye;Park, Hye Min;Lee, Boeun;Kim, Ji-hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.281-292
    • /
    • 2021
  • Cranial-nerve disorders can be caused by a wide spectrum of diseases, including congenital, inflammatory, and tumorous diseases, and are often encountered in practice. However, the imaging of cranial-nerve disorders is challenging, and understanding the anatomical differences of each region is essential for conducting the best protocols and for detecting subtle changes in cranial nerves during magnetic resonance imaging (MRI) examinations. In this review we discuss which MRI techniques are best for observing normal and pathologic appearance, according to the different regions of the cranial nerves.

개의 경막외 혈종의 자기공명영상학적 진단 (MAGNETIC RESONANCE IMAGING APPEARANCE OF EPIDURAL HEMATOMA IN DOG)

  • 최치봉;김휘율;김수관;배춘식
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.488-491
    • /
    • 2005
  • A 3-year-old female, 5kg, Shih-tzu developed an acute onset of depression, disorientation, hypersalivation, nystagmus after falling down 2 meter height place. In plain skull radiography, there was fracture line in the frontal and parietal bones and next day magnetic resonance imaging examination was performed. Magnetic resonance imaging of the brain was performed with 3.0 Tesla unit. Under general anesthesia, the dog was placed in prone with its head positioned in a birdcage coil. Transverse, sagittal and coronal fast spin echo images of the brain were obtained with the following pulse sequences: T1 weighted images (TR = 560 ms and TE = 18.6 ms) and T2 weighted images (TR = 3500 ms and TE = 80 ms). Magnetic resonance imaging showed epidural hematoma in the left frontal area resulting in compression of the adjacent brain parenchyma. Left lateral ventricle was compressed secondarily and the longitudinal fissure shifted to the right, representing mass effect. The lesion was iso-to slightly hyperintense on T1 weighted image and iso-slightly hypointense signal on T2 weighted image. At necropsy, there was a skull fracture and epidural hematoma in the left frontal area. Magnetic resonance imaging of epidural hematoma is reviewed.

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

$^{11}B$ Nuclear Magnetic Resonance Study of Calcium-hexaborides

  • Mean, B.J.;Lee, K.H.;Kang, K.H.;Lee, Moo-Hee;Lee, J.S.;Cho, B.K.
    • 한국자기공명학회논문지
    • /
    • 제7권2호
    • /
    • pp.80-88
    • /
    • 2003
  • We have performed $^{11}$ B nuclear magnetic resonance (NMR) measurements to microscopically investigate an electronic structure of the ferromagnetic state in three different compositions of calcium-hexaboride single crystals. Although the crystal structure of Ca $B_{6}$ is cubic and three NMR lines may be expected for the nuclear spin 3/2 of $_{11}$ B, a larger number of NMR resonance peaks have been observed. The frequency and intensity of those peaks distinctively changes depending on the angle between crystalline axis and magnetic field. Analyzing this behavior, we find that the electric field gradient(EFG) tensor at the boron has its principal axis perpendicular to the six cubic faces with a quadrupole resonance frequency $v_{Q}$ 600 kHz. Even though the magnetization data highlight the ferromagnetic hysteresis, $^{11}$ B NMR linewidth data show no clear microscopic evidence of the ferromagnetic state in three different compositions of Ca $B_{6}$ single crystals.s.

  • PDF