• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.025 seconds

Design of Multi-Sensor-Based Open Architecture Integrated Navigation System for Localization of UGV

  • Choi, Ji-Hoon;Oh, Sang Heon;Kim, Hyo Seok;Lee, Yong Woo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • The UGV is one of the special field robot developed for mine detection, surveillance and transportation. To achieve successfully the missions of the UGV, the accurate and reliable navigation data should be provided. This paper presents design and implementation of multi-sensor-based open architecture integrated navigation for localization of UGV. The presented architecture hierarchically classifies the integrated system into four layers and data communications between layers are based on the distributed object oriented middleware. The navigation manager determines the navigation mode with the QoS information of each navigation sensor and the integrated filter performs the navigation mode-based data fusion in the filtering process. Also, all navigation variables including the filter parameters and QoS of navigation data can be modified in GUI and consequently, the user can operate the integrated navigation system more usefully. The conventional GPS/INS integrated system does not guarantee the long-term reliability of localization when GPS solution is not available by signal blockage and intentional jamming in outdoor environment. The presented integration algorithm, however, based on the adaptive federated filter structure with FDI algorithm can integrate effectively the output of multi-sensor such as 3D LADAR, vision, odometer, magnetic compass and zero velocity to enhance the accuracy of localization result in the case that GPS is unavailable. The field test was carried out with the UGV and the test results show that the presented integrated navigation system can provide more robust and accurate localization performance than the conventional GPS/INS integrated system in outdoor environments.

Statistical Study of Conservative Treated Herniated Intervertebral Lumbar Disc (요추 추간판탈출증 환자의 보존적 치료에 대한 통계적 연구)

  • Kim, Su-Jang;Kim, Yong;Kim, Sung-Yong;Lee, Jeong-Hun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.3 no.1
    • /
    • pp.43-53
    • /
    • 2002
  • Objectives : The object is to study a clinical effect regarding the conservative treatment of the patient who was diagnosed as the herniated Intervertebral lumbar disc(HIVD) and hospitalized in the oriental medical hospital and clinical study about the type of the HIVD. Methods. The clinical studies were done on 65 cases (hospitalized in Dept. of Oriental Rehabilitation Medicine, jaseng on oriental medical hospital from June 2001 to May 2002) who complained of low back pain or sciatica and diagnosed as HIVD on CT(computerized tomography) or MRI(magnetic resonance imaging). They were given both oriental conservative treatment and exercise during the hospitalization period. We investigated and observed 20 items about sex, age, weight, height, occupation, smoking. obesity, duration of disease, clinical symptom and treatment duration in basis of medical recording which was drawn up at patient hospitalization. We classified HIVD with 4 types(Bulging. Protruded. Extruded, Sequestered) and decided the case which simultaneously had 2 overs with Mixed type. The treatment evaluation standard was classified with 4 branches; Excellent. Good, Fair and Poor. Results & Conclusions : The treatment result of over 'fair' is bulging type 85%, protruded type 92.7%, extruded type 100% and the mixed type was 85.1 %. The effect was good in order of bulging, mixed, protruded and extruded type. It appeared most plentifully with 30 people in L4-5 and L5-S 1 disc herniation type.

  • PDF

fMRI Investigation on Cue-induced Smoking Craving:A Case Report (흡연갈망의 신경해부학적 특이성:기능자기공명영상연구)

  • Lim, Hyun-Kook;Pae, Chi-Un;Lee, Chang-Uk
    • Korean Journal of Biological Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.68-72
    • /
    • 2005
  • Object:Nicotine dependence is the most common substance abuse disorder. One of the characteristics of nicotine dependence is craving. Regional activation of the brain induced by craving for nicotine was evaluated by using functional magnetic resonance imaging to investigate neuroanatomical site of smoking craving. Method:A smoker who satisfied DSM-IV criteria for nicotine dependence and a non smoker was studied. MRI data were acquired on a 1.5T Magnetom Vision Plus with a head volume coil. Two sets of visual stimuli were presented to subjects in a random manner. One was the film scenes of inducing smoking craving and the other was neutral stimuli not related to smoking. There were two fMRI sessions before and after smoking or sham smoking. Data were analyzed using SPM99. Results:fMRI showed significant activated area in anterior cingulate and medial frontal lobes in the smoker during smoking craving. Right dorsolateral prefrontal cortex and parietal lobes were activated in the control during visual stimulation before smoking. After smoking, there was no brain activation during visual stimulation in both of smoker and non smoker. Conclusion:Metabolic activity of the anterior cingulate and medial frontal lobes increased during craving for smoking. This result suggests that fMRI may be a valuable tool in the identification of neurobiological process of craving.

  • PDF

A Study on the Detection Characteristics of the Magneto-Plethysmography According to Fluid Properties (유체의 성질에 따른 자계용적맥파의 검출 특성에 관한 연구)

  • Kim, Sang-Min;Lee, Kang-Hwi;Lee, Seong-Su;Lee, Hyeok-Jae;Lee, Byoung-Hun;Kim, Kyeoung-Seop;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.946-953
    • /
    • 2018
  • Photo-plethysmography (PPG), which measures changes in the peripheral blood flow of a human body using difference in absorption rate of light, is a measurement method that is studied and used in clinical and various applications due to its simple circuit configuration and measurement convenience. Magneto-plethysmography (MPG), which is newly developed by our team, is a method of measuring changes in the conductivity of biological tissues by using a eddy current induced by a time-varying magnetic field, and is not subject to optical interference. In this study, we investigated the detection characteristics of MPG according to the change of the conductivity of the object and fluid to be measured by simultaneously measuring PPG and MPG. In order to control the speed of fluid known in advance, a blood flow simulator was implemented and used. The fluid used in the experiment was general mineral water and physiological saline (0.9% NaCl) solution. Experimental results show that the amplitude change of the measured PPG was 0.3% in normal water and saline solution, and that of MPG was 77.3%. Therefore, it is considered that the magneto-plethysmography (MPG) has a strong correlation with the conductivity of the fluid.

Analysis of Pineal Cyst ; Clinical and Radiological Characteristics (송과체 낭종의 임상적, 방사선학적 특성 분석)

  • Kim, Yong-Su;Jung, Shin;Yoon, Sang-Won;Lee, Jung-Kil;Kim, Tae-Sun;Kim, Jae-Hyoo;Kim, Soo-Han;Kang, Sam-Suk;Lee, Je-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.899-903
    • /
    • 2000
  • Objective : Object : A 7-year retrospective clinical and MRI study was reviewed to evaluate the characteristics of pineal cyst. We evaluated results of clinical and radiologic change of pineal cyst during follow up period. Patients and Methods : From 1992 to 1999, 50 patients with pineal cyst were visited for evaluation. Follow up clinical information was obtained from patients or clinical record through phone conversation. also radiologic findi-ngs of pineal cyst in mid-sagittal MRI were reviewed in detail. Results : Pineal cysts were usually asymptomatic and detected incidentally during evaluation of other diseases. Sagittal MRI is the most useful diagnostic test. The radiologic findings of pineal cyst were isointensity on T1WI comared to CSF and slightly high signal intensity on T2WI. Cyst wall was variably enhanced on Gad-enhanced T1WI. The average size of cyst was $13.9{\times}13.0mm$. The pineal cyst was classified into five groups according to previous report. Long term behavior of these lesions are not apparent, but in our study they showed no specific changes in clinical and radiological aspects during 25 months. Conclusion : Although long-term follow up results are needed, the pineal cyst are considered as normal variants. In our 25 months follow up results, there was no rapid change of cyst both clinically and radiologically. Therefore, frequent radiologic evaluation seems unnecessary except type III pineal cyst.

  • PDF

Fuzzy Modeling and Stability Analysis of Wind Power System with Doubly-fed Induction Generator (이중여자 유도발전기 기반 풍력발전 시스템의 퍼지 모델링 및 안정도 해석)

  • Kim, Jin-Kyu;Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.1
    • /
    • pp.56-61
    • /
    • 2012
  • This paper propose the robust stability algorithm for controlling a variable speed wind power system which based on doubly-fed induction generator (DFIG). The control object in the wind power system enables the rotor to rotate without any physical contact by using magnetic force. Generally, the system dynamics of the wind power system has severe nonlinearity and uncertainty so that it is not easy to obtain the control objective. For solving these problems, we propose the fuzzy modelling and robust control algorithm for wind power system. The sufficient conditions for robust controller are obtained in terms of solutions to linear matrix inequalities (LMIs). Simulation results for wind power system based on DFIG are demonstrated to visualize the feasibility of the proposed method.

The design and fabricationt for ion fraction measurement of plasma generator (플라즈마발생기의 이온분율 측정 장치 설계 및 제작)

  • Lee, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF

THE STUDY ON ANTERIOR DISPLACEMENT OF DISK IN PATIENTS OF TEMPOROMANDIBULAR JOINT INTERNAL DERANGEMENT IN MAGNETIC RESONACE IMAGING (측두하악관절 내장증 환자의 자기공명영상에서 관절 원판의 전방 이동에 관한 연구)

  • Moon, Chang-Soo;Cho, Byoung-Ouck;Lee, Yong-Chan;Lee, Han-Ouck;You, Han-Shick;Lee, Yul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.189-197
    • /
    • 1993
  • Tempormandibular Joint pain and dysfunction is a common and important clinical problem. With the recent advances in imaging technology, radiologists have made major contribution to the understanding of TMJ disease. The MRI has several advantages over the conventional imaging methods. It is possible to obtain surprisingly precise images of internal hard and soft tissues with MRI. It is not invasive without ionizing radiation. The abnormal disk position has been thought as the cause of TMJ internal derangement. But there are few methods to relate disk position to TMJ internal derangement quantatively. The object of our study is to determine the amount of anterior displacement fo articular disk in symptomatic patients related each symptoms. Using the method of Dr. Drace, we studied the 38 joints of 22 persons with susceptable TMJ internal derangement. 1. In determining the anterior displacement of TMJ articular disk, the junction between the posterior band and bilaminar zone was useful. 2. The mean anterior displacement of disk in reduction group and without reduction group were $51.0^{\circ}C$ and $81.1^{\circ}C$ respectively. The difference was significant. 3. In the mean anterior displacement of disk, the pain without clicking group showed $84.8^{\circ}C$ and the clicking and pain group $70.8^{\circ}C$, the clicking group respectively.

  • PDF

Study on the Artifact pattern representation of a method using digital technology (디지털 기술을 이용한 유물의 문양표현 방법에 대한 연구)

  • Koo, Ja-Bong
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.113-121
    • /
    • 2015
  • Artifact pattern representation of a method using the digital technology is largely are two digital rubbing technique and digital contrast technique. Digital rubbing technique is clearly with the naked eye to see the original prestigious and difficult to build a digital rubbing data patterns by scanning a prestigious and patterns carved into the artifacts in three dimensions without compromising the circle to represent the three-dimensional effect by contrast it to the objective value refers to a technique that can be represented in digital. Digital contrast technique can not be calculated if the depth information of the object due to the glassy film of artefacts in a three-dimensional surface scanning and the application of this technique refers to a realistic image mapped digital technique for generating digital image contrast. Digital rubbing technique is mainly useful to express the most prestigious and patterns expressed in pottery or tile and stone monument, etc. engraved or embossed, digital contrast techniques can be used effectively to artifacts such as magnetic or glass can not be applied to the digital rubbing technique.

Light-weight Signal Processing Method for Detection of Moving Object based on Magnetometer Applications (이동 물체 탐지를 위한 자기센서 응용 신호처리 기법)

  • Kim, Ki-Taae;Kwak, Chul-Hyun;Hong, Sang-Gi;Park, Sang-Jun;Kim, Keon-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.153-162
    • /
    • 2009
  • This paper suggests the novel light-weight signal processing algorithm for wireless sensor network applications which needs low computing complexity and power consumption. Exponential average method (EA) is utilized by real time, to process the magnetometer signal which is analyzed to understand the own physical characteristic in time domain. EA provides the robustness about noise, magnetic drift by temperature and interference, furthermore, causes low memory consumption and computing complexity for embedded processor. Hence, optimal parameter of proposal algorithm is extracted by statistical analysis. Using general and precision magnetometer, detection probability over 90% is obtained which restricted by 5% false alarm rate in simulation and using own developed magnetometer H/W, detection probability over 60~70% is obtained under 1~5% false alarm rate in simulation and experiment.