• 제목/요약/키워드: Magnetic Materials

검색결과 3,872건 처리시간 0.029초

Prognostic implications of tumor volume response and COX-2 expression change during radiotherapy in cervical cancer patients

  • Noh, Jae Myoung;Park, Won;Huh, Seung Jae;Cho, Eun Yoon;Choi, Yoon-La;Bae, Duk Soo;Kim, Byoung-Gie
    • Radiation Oncology Journal
    • /
    • 제30권4호
    • /
    • pp.218-225
    • /
    • 2012
  • Purpose: The relationship between treatment outcomes, alteration of the expression of biological markers, and tumor volume response during radiotherapy (RT) in patients with uterine cervical cancer was analyzed. Materials and Methods: Twenty patients with cervical squamous cell carcinoma received definitive RT with (n = 17) or without (n = 3) concurrent chemotherapy. Tumor volumes were measured by three serial magnetic resonance imaging scans at pre-, mid-, and post-RT. Two serial punch biopsies were performed at pre- and mid-RT, and immunohistochemical staining for cyclooxygenase (COX)-2 and epidermal growth factor receptor was performed. The median follow-up duration was 60 months. Results: The median tumor volume response at mid-RT (V2R) was 0.396 (range, 0.136 to 0.983). At mid-RT, an interval increase in the distribution of immunoreactivity for COX-2 was observed in 8 patients, and 6 of them showed poor mid-RT tumor volume response ($V2R{\geq}0.4$). Four (20%) patients experienced disease progression after 10 to 12 months (median, 11 months). All 4 patients had poor mid-RT tumor volume response (p = 0.0867) and 3 of them had an interval increase in COX-2 expression. Overall survival (OS) and progression-free survival (PFS) decreased in patients with $V2R{\geq}0.4$ (p = 0.0291 for both). An interval increase in COX-2 expression at mid-RT was also associated with a decreased survival (p = 0.1878 and 0.1845 for OS and PFS, respectively). Conclusion: Poor tumor volume response and an interval increase in COX-2 expression at mid-RT decreased survival outcomes in patients with uterine cervical cancer.

비파괴 전자탐사에 의한 지하 매설물의 정밀탐지 (Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey)

  • 손호웅;이승희;이강원
    • 비파괴검사학회지
    • /
    • 제22권3호
    • /
    • pp.275-283
    • /
    • 2002
  • 지하에 매설된 각종 시설물의 위치 및 깊이를 조사하기 위한 비파괴적인 조사방법으로 GPR(Ground Penetrating Radar; 지하투과레이다; 지하레이다) 탐사법이 국내외적으로 많이 활용되고 있으나, 가탐심도가 일반적적로 5m이내로서 낮으며, 지하매질이 불균질하거나 점토, 염분, 자갈 등이 많은 곳 및 주변의 전자기적 잡음이 심한 곳에서는 조사가 안 되는 경우가 많다. 본 연구에서는 이러한 비파괴 GPR 탐사법의 제약을 극복하고자 일반적인 매설심도(물리탐사적으로는 얕은 곳)에 위치한 지하매설물임에도 불구하고 탐지가 안 되는 지역을 선정하여, 토질분석에 의해 탐사가 되지 않는 원인규명과 함께 효과적으로 지하매설물을 탐지할 수 있는 새로운 비파괴 전자(電磁) 탐사법을 제시하였다. 본 연구에서는 2kHz-4MHz 대역의 지하조사를 위한 고주파수대역 전자탐사법을 개발, 적용하였다. 고주파수대역 전자 탐사는 주파수대역 탐사이며 인공적으로 에너지원(源)을 방출하는 능동적인 탐사법으로서 가탐심도는 약30m 정도이다. 서로 수직한 전기장과 자기장을 측정하여 임피던스를 계산하며, 이로부터 측점 하부의 수직적인 전기비저항 분포를 해석하게 된다. 또한, 비접촉 용량전극을 채택하여 측정시간을 대폭 줄일 수 있을 뿐만 아니라 콘크리트, 아스팔트 및 잡석으로 포장된 지역에서도 조사가 용이하며, 신호중첩에 의해 고압선 등에 의한 잡음을 감소시킬 수 있게 되었다. 다른 탐사방법으로는 발견할 수 없었던 지하매설관에 대해서 본 고주파수대역 전자탐사를 성공적으로 정밀하게 적용할 수 있었다. 본 연구 결과를 지하매설물의 위치 및 깊이 확인을 위한 정밀 지하측량 지반조사 및 문화 유적지조사 등에 효과적으로 적용할 수 있을 것으로 판단된다.

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

술폰산으로 표면개질된 메조기공 실리카 촉매의 제조 및 Octamethylcyclotetrasiloxane 개환중합에서의 촉매 활성 (Mesoporous Silica Catalysts Modified with Sulfonic Acid and Their Catalytic Activity on Ring Opening Polymerization of Octamethylcyclotetrasiloxane)

  • 이연송;황하수;이지영;로누호앙티엔;느윙티엔지앙;이동현;박인
    • 공업화학
    • /
    • 제31권4호
    • /
    • pp.383-389
    • /
    • 2020
  • 프로필 술폰산으로 개질된 메조기공 실리카 고체 산 촉매를 octamethylcyclotetrasiloxane (D4)의 양이온 개환중합을 위해 합성하였다. 서로 다른 기공 크기를 갖는 두 세트의 MCM-41 (1.7 및 2.8 nm) 및 SBA-15 (8.1 및 15.9 nm)을 촉매의 지지체로 사용하였고, 이를 (3-mercaptopropyl)trimethoxysilane으로 표면개질하고 산화시켜 술폰산으로 개질된 고체 산촉매를 제조하였다. 제조된 촉매는 기공 크기와 비표면적, 기공 부피가 약간씩 감소하였음을 X선 회절, 질소흡탈착을 통하여 확인하였다. 또한 적외선분광법과 핵자기공명법의 분광학적 방법을 이용하여 술폰산이 개질되었음을 확인하였다. 입도의 촉매 활성에 대한 효과를 관찰하기 위하여 주사전자현미경으로 관찰하였다. D4의 개환중합을 통한 PDMS 합성을 위하여 촉매를 사용하였으며, 중합 반응의 전환율과 중합 속도는 촉매의 기공 크기, 비표면적, 입자크기 및 입자의 응집도에 의존하였다. 중합 속도의 순서는 8.1 nm의 SBA-15으로 제조한 촉매가 가장 반응속도가 빨랐으며, 가장 좋은 촉매 활성을 보였다.

외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술 (Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder)

  • 김승호;하권익;유재철;이용석;이희동
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성 (Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear)

  • 염재광;신용운;한정일
    • Clinics in Shoulder and Elbow
    • /
    • 제11권1호
    • /
    • pp.24-28
    • /
    • 2008
  • 목적: 본 연구의 목적은 수술 전 회전근 개 파열에 대한 3차원 초음파 검사의 시행은 파열의 실제 크기를 수술 전 확인하는 데 유용함을 보고하고자 하는 것이다. 대상 및 방법: 자기공명영상 촬영상 회전근 개 완전 파열이 있어 수술을 시행한 환자 중 수술 전 3차원 초음파 검사를 시행하여 파열의 크기를 측정하였고, 수술시 회전근 개의 실제 크기를 측정하여 비교하였다. 이 연구에는 수술 시 회전근 개 완전 파열이 확인된 15예(남자가 7명, 여자가 8명)가 포함되었다. 평균 연령은 55.4세($47{\sim}67$)였으며, 우측 견관절은 13예, 좌측 견관절은 2예였다. 결과: 수술 전 초음파 검사로 측정한 파열의 크기와 실제 수술시 측정한 크기의 차이는 가로 길이는 평균 0.7 mm의 오차를 보였고, 세로 길이는 평균 2.0 mm의 오차를 보였다. 결론: 수술 전 3차원 초음파 검사와 실제 수술시 측정한 회전근 개 파열의 가로 및 세로 크기가 거의 일치함을 보여 수술 전 3차원 초음파 검사는 매우 유용한 검사로 사료된다.

회전근 개 파열 봉합술 후 재파열 환자에서 임상결과와 원인 인자 (Clinical Outcome and Causative Factor in Patients of Structural Failure after Rotator Cuff Repair)

  • 전재명;송정석;손동욱
    • Clinics in Shoulder and Elbow
    • /
    • 제11권1호
    • /
    • pp.29-36
    • /
    • 2008
  • 목적: 회전근 개 파열의 개방적 봉합술 후 임상적 결과와 회전근 개 연속성의 연관성을 알아보고 재파열 발생의 요인을 분석하고자 하였다. 대상 및 방법: 2004년부터 2006년까지 회전근 개 파열로 수술적 봉합술을 시행받은 78명의 환자를 대상으로 하였다. 모든 환자는 최소 1년 이상 추시하여 자기 공명 영상(MRI)을 촬영하고 재파열 유무를 확인하였다. 임상 결과는 재파열된 군과 유지된 군으로 나누어 평가하였다. 재파열의 원인 분석을 위해 수술전 파열의 크기, 유병 기간 등을 양군에서 비교하였다. 결과: 회전근 개 재파열군(n=22)의 수술후 임상결과는 수술전에 비하여 의미있게 호전되었으나(p<0.001, p<0.001). 근력은 수술후 의미있게 호전되지 않았다(p=0.099, p=0.243). 수술전 파열의 크기가 컸던 환자에서 재파열이 많았으며(p<0.001), 재파열된 군은 수술전 유병기간이 길었다(p=0.027). 결론: 회전근 개 개방적 봉합술 후 재파열이 되더라도 임상 결과는 호전되나 극상근과 외회전근의 근력은 의미있게 호전되지 않았다. 수술전 파열의 크기가 크고 유병 기간이 긴 경우에 수술후 재파열의 빈도가 높았다.

전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향 (Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast)

  • 윤종준;정지욱;황주원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.57-61
    • /
    • 2012
  • 전신 뼈 검사에 이용되는 방사성의약품의 주된 집적부위는 뼈 무기질이며 그 섭취기전은 명백히 밝혀져 있지 않다. 전신 뼈 검사에서 일시적으로 미만성 간 섭취가 나타날 수 있으며, 간내 섭취의 원인은 다양하게 보고되고 있다. 본 연구에서는 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 미치는 영향을 알아보았다. 2010년 1월부터 12월 사이에 $^{99m}Tc$-DPD 전신 뼈 검사를 시행한 환자 중 982명을 연구의 대상으로 하였다. 982명의 환자는 전신 뼈 검사 이전에 MRI 조영제를 사용한 검사를 시행하였다. 혈액학검사 및 일반화학검사 소견을 조사한 결과 전신 뼈 검사에서 46명의 환자(남:여=39:7)가 미만성 간 섭취를 보였다. 추적 전신 뼈 검사를 시행하였으며, 이전에 보였던 미만성 간 섭취는 모두 소실되어 정상적인 소견을 보였다. 간기능 및 신기능 검사는 모두 정상이었다. 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 간접적인 영향을 주고 있다. $^{99m}Tc$-DPD의 미만성 간 섭취를 피하기 위해서 전신 뼈 검사는 MRI 조영제를 사용한 검사를 시행하기에 앞서서 먼저 시행하여야 하고, MRI 조영제를 사용한 검사가 있을 경우에는 조영제가 몸에서 제거된 후 검사를 시행하여야 할 것이다.

  • PDF

Establishment of a [18F]-FDG-PET/MRI Imaging Protocol for Gastric Cancer PDX as a Preclinical Research Tool

  • Bae, Seong-Woo;Berlth, Felix;Jeong, Kyoung-Yun;Suh, Yun-Suhk;Kong, Seong-Ho;Lee, Hyuk-Joon;Kim, Woo Ho;Chung, June-Key;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • 제20권1호
    • /
    • pp.60-71
    • /
    • 2020
  • Purpose: The utility of 18-fluordesoxyglucose positron emission tomography ([18F]-FDG-PET) combined with computer tomography or magnetic resonance imaging (MRI) in gastric cancer remains controversial and a rationale for patient selection is desired. This study aims to establish a preclinical patient-derived xenograft (PDX) based [18F]-FDG-PET/MRI protocol for gastric cancer and compare different PDX models regarding tumor growth and FDG uptake. Materials and Methods: Female BALB/c nu/nu mice were implanted orthotopically and subcutaneously with gastric cancer PDX. [18F]-FDG-PET/MRI scanning protocol evaluation included different tumor sizes, FDG doses, scanning intervals, and organ-specific uptake. FDG avidity of similar PDX cases were compared between ortho- and heterotopic tumor implantation methods. Microscopic and immunohistochemical investigations were performed to confirm tumor growth and correlate the glycolysis markers glucose transporter 1 (GLUT1) and hexokinase 2 (HK2) with FDG uptake. Results: Organ-specific uptake analysis showed specific FDG avidity of the tumor tissue. Standard scanning protocol was determined to include 150 μCi FDG injection dose and scanning after one hour. Comparison of heterotopic and orthotopic implanted mice revealed a long growth interval for orthotopic models with a high uptake in similar PDX tissues. The H-score of GLUT1 and HK2 expression in tumor cells correlated with the measured maximal standardized uptake value values (GLUT1: Pearson r=0.743, P=0.009; HK2: Pearson r=0.605, P=0.049). Conclusions: This preclinical gastric cancer PDX based [18F]-FDG-PET/MRI protocol reveals tumor specific FDG uptake and shows correlation to glucose metabolic proteins. Our findings provide a PET/MRI PDX model that can be applicable for translational gastric cancer research.

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.