• 제목/요약/키워드: Magnetic Field Strength

검색결과 395건 처리시간 0.02초

Magnetic Contactor Upper Frame 사출성형시 유리섬유 배향에 따른 뒤틀림 변형에 관한 연구 (A study of warpage caused by glass fiber orientation in Injection Molding to Upper Frame of Magnetic Contactor in 85 AF)

  • 박진영;조해용;김길수;황한성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.766-771
    • /
    • 2000
  • As using of insulating material of plastic to industrial electric field, thermoset has been gradually substituted for thermoplastic. But changing the material with crystalline has some problem, which is strength or warpage, Especially getting a strength to endure inner pressure is necessary when arc is occurred. So we use the material that is composed of glass fiber to compensate strength. By the way as the reinforced glass-fiber material is used in injection molding, unstableness of dimension is appeared frequently and it is difficult to know warpage pattern. So this paper will be contributed to know warpage pattern of mold product that is upper frame of magnetic contactor caused by glass-fiber orientation with fixed gate-system, when glass-fiber reinforced material with classification of poly-amide is used in injection molding.

  • PDF

Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field

  • Jung, Nuri Hyun;Shin, Youngseob;Jung, In-Hye;Kwak, Jungwon
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.226-232
    • /
    • 2015
  • Purpose: Toxicity of mucosa is one of the major concerns of radiotherapy (RT), when a target tumor is located near a mucosal lined organ. Energy of photon RT is transferred primarily by secondary electrons. If these secondary electrons could be removed in an internal cavity of mucosal lined organ, the mucosa will be spared without compromising the target tumor dose. The purpose of this study was to present a RT dose reduction in near target inner-surface (NTIS) of internal cavity, using Lorentz force of magnetic field. Materials and Methods: Tissue equivalent phantoms, composed with a cylinder shaped internal cavity, and adjacent a target tumor part, were developed. The phantoms were irradiated using 6 MV photon beam, with or without 0.3 T of perpendicular magnetic field. Two experimental models were developed: single beam model (SBM) to analyze central axis dose distributions and multiple beam model (MBM) to simulate a clinical case of prostate cancer with rectum. RT dose of NTIS of internal cavity and target tumor area (TTA) were measured. Results: With magnetic field applied, bending effect of dose distribution was visualized. The depth dose distribution of SBM showed 28.1% dose reduction of NTIS and little difference in dose of TTA with magnetic field. In MBM, cross-sectional dose of NTIS was reduced by 33.1% with magnetic field, while TTA dose were the same, irrespective of magnetic field. Conclusion: RT dose of mucosal lined organ, located near treatment target, could be modulated by perpendicular magnetic field.

WPT 시스템의 누설자계 감소를 위한 전자파 차폐구조 개선 (Improvement of Electromagnetic Shielding Structure for Reduction of the Leakage Magnetic Field in WPT System)

  • 김종찬;이승우;강병남;홍익표;조인귀;김남
    • 한국전자파학회논문지
    • /
    • 제28권1호
    • /
    • pp.61-68
    • /
    • 2017
  • 본 논문에서는 저주파 대역에서 동작하는 무선전력전송 시스템에서 발생하는 자기장을 저감하기 위한 개선된 자기장 저감 구조를 제안하였다. 제안된 구조는 자성체와 도체로 구성되었으며, 적용된 다양한 설계 파라미터를 최적화하여 전력전송을 위한 자기장의 상쇄효과는 최소화 하면서 시스템 주변으로 누설되는 자기장 상쇄효과는 개선되도록 하였다. 무선전력전송 시스템의 효율과 주변으로 누설되는 자기장 저감 효과를 컴퓨터 시뮬레이션과 측정을 통하여 분석 및 검증을 하였다. 시뮬레이션 분석 결과, 제안된 구조가 적용된 무선전력전송 시스템의 전력전송효율은 약 77 % 수준으로 기존의 전력전송효율과 동등한 수준을 유지하였다. 또한, 고효율을 유지하는 구조들과 비교하여 최대 근접지점에서 누설되는 자기장의 세기를 약 29~37 % 저감할 수 있었다.

THE EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD (ELF-MF) ON THE FREQUENCY OF MICRONUCLEI IN HUMAN LYMPHOCYTES INDUCED BY BENZO(A)PYRENE

  • Cho, Yoon-Hee;Kim, Su-Young;Chung, Hai-Won
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2001년도 International Symposium on Dietary and Medicinal Antimutgens and Anticarcinogens
    • /
    • pp.178-178
    • /
    • 2001
  • The interaction of extremely low frequency magnetic field (ELF-MF) on the frequency of micronuclei (MN) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-MF of 0.8 mT field strength was applied for 24 hours either alone or with the tumour initiator, BP. The frequency of MN induced by BP increased in a dose-dependent manner.(omitted)

  • PDF

Enhancement of the Magnetic Flux in Metglas/PZT-Magnetoelectric Integrated 2D Geomagnetic Device

  • Huong Giang, D.T.;Duc, P.A.;Ngoc, N.T.;Hien, N.T.;Duc, N.H.
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.308-315
    • /
    • 2012
  • Experimental investigations of the magnetization, magnetostriction and magnetoelectric (ME) effects were performed on sandwich - type Metglas/PZT/Metglas laminate composites. The results have been analyzed by taking into account the demagnetization contribution. The study has pointed out that the magnetic flux concentration is strongly improved in piezomagnetic laminates with a narrower width leading to a significant enhancement of the ME effects. The piezomagnetic laminates with the optimal area dimension were integrated to form a 2-D geomagnetic device, which simultaneously can precisely detect the strength as well as inclination of the earth's magnetic field. In this case, a magnetic field resolution of better than $10^{-4}$ Oe and an angle precision of ${\pm}0.1^{\circ}$ were determined. This simple and low-cost geomagnetic-field device is promising for various applications.

Nanoparticle Contrast in Magneto-Motive Optical Doppler Tomography

  • Kim, Jee-Hyun;Oh, Jung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • 제10권3호
    • /
    • pp.99-104
    • /
    • 2006
  • We introduce a novel contrast mechanism for imaging superparamagnetic iron oxide (SPIO) nanoparticles (average diameter ${\sim}100nm$) using magneto-motive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect the nanoparticles flowing through a glass capillary tube. A solenoid cone-shaped ferrite core extensively increased the magnetic field strength ($B_{max}=1\;T,\;{\Delta}|B|^2=220T^2/m$) at the tip of the core and also focused the magnetic force on targeted samples. Nanoparticle contrast was demonstrated in a capillary tube filled with the SPIO solution by imaging the Doppler frequency shift which was observed independent of the flow rate and direction. Results suggest that MM-ODT may be a promising technique to enhance SPIO nanoparticle contrast for imaging fluid flow.

전자기 용접의 충돌 속도에 대한 코일 형상의 영향 (Effect of a Coil Shape on an Impulse Velocity of the Electromagnetic Welding)

  • 박현일;이광석;이진우;이영선;김대용
    • 소성∙가공
    • /
    • 제28권3호
    • /
    • pp.135-144
    • /
    • 2019
  • Electromagnetic impulse welding (EMIW) is a type of solid state welding using the Lorentz force generated by interaction between the magnetic field of the coil and the current induced in the workpiece. Although many experimental studies have been investigated on the expansion and compression welding of tube using the EMIW process, studies on the EMIW process of lap joint between flat sheets are uncommon. Since the magnetic field enveloped inside the tube can be controlled with ease, the electromagnetic technique has been widely used for tube welding. Conversely, it is difficult to control the magnetic field in the flat sheet welding so as to obtain the required welding velocity. The current study analyzed the effects of coil shape on the impulse velocity for suitable flat one-turn coil for the EMIW of the flat sheets. The finite element (FE) multi-physics simulation involving magnetic and structural field of EMIW were conducted with the commercial software LS-DYNA to evaluate the several shape variables, viz., influence of various widths, thicknesses, gaps and standoff distances of the flat one-turn coil on the impulse velocity. To obtain maximum impulse velocity, the flat one-turn coil was designed based on the FE simulation results. The experiments were performed using an aluminum alloy 1050 sheets of 1.0mm thickness using the designed flat one-turn coil. Through the microscopic interfacial analysis of the welded specimens, the interfacial connectivity was observed to have no defects. In addition, the single lap joint tests were performed to evaluate the welding strength, and a fracture occurred in the base material. As a result, a flat one-turn coil was successfully designed to guarantee welding with bond strength equal to or greater than the base material strength.

자기장 영향에 따른 자기유변탄성체의 구름 마찰 특성 연구 (A Study on Rolling Friction Characteristics of Magneto-Rheological Elastomer under Magnetic Fields)

  • 연성룡;이광희;김철현;이철희
    • Tribology and Lubricants
    • /
    • 제30권4호
    • /
    • pp.234-239
    • /
    • 2014
  • Magneto-rheological elastomer (MR elastomer) is a smart material, because it has mechanical properties that change under a magnetic field. An MR elastomer changes its stiffness characteristics when the inner particles (iron particles) align along the direction of a magnetic field. There has been much research to make use of this characteristic to control vibration issues in various mechanical systems, such as for mounting systems in the automotive field, home appliances, etc. Furthermore, the friction and wear properties of MR elastomer have been studied, as these relate to the durability of the material needed to meet engineering requirements. Rolling friction (or rolling resistance) is one of these friction properties, but has not yet been studied in the context of MR elastomers. In this study, an MR elastomer is fabricated in the shape of a hollow cylinder to evaluate the rolling friction characteristic under a magnetic field. The test apparatus is setup and a strain gauge is used to calculate the rolling resistance under test conditions. Permanent magnets are used to supply the magnetic field during tests. The load and rolling speed conditions are also considered for the tests. The test results show that rolling friction characteristic has a different trend under different magnetic field, load, and rolling speed conditions. It is assumed that the stiffness change of an MR elastomer under a magnetic field has an effect on the rolling friction characteristic of the MR elastomer. For the future work, the rolling friction characteristics of MR elastomers will be controlled by adjusting the strength of the magnetic field using electromagnets.

345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석 (Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.14-21
    • /
    • 1998
  • 본 논문에서는 평판형 전장센서와 멀티턴 루우프형 자장센서를 이용하여 2회선 345[kV] 송전선로에서 발생하 는 극저주파 영역(ELF)의 전장과 자장의 값을 측정하고, 이들의 크기를 3차원 그립으로 나타내었다. 또한, 자장 은 부하전류에 비례하므로 부하변동에 따른 자장의 값올 예측할 수 있도록 그 송전선로의 대표적인 일부하 전류 곡선을 나타내었다 선로 중심점으로부터 횡방향 거리에 대한 측정값을 FIELDS 프로그램에 의해 계산된 이론 값과 비교하였다. 전장의 세기는 송전 철탑 내부와 주변에서 낮게 나타났고, 자장의 경우 최대값이 나타난 지점 은 중부하 회선쪽으로 이동하였으나, 대체로 철탑의 중심부분에서 최대치가 나타나는 경향을 보였다. 송전철탑 주변에서 최대 전장과 자장의 값은 각각 3.5[kV/m]와 $20[{\mu}T]$ 를 초과하지 않았으며, 본 연구에서 측정된 전장과 자장의 값은 관련 여러 국제기관에서 제시한 제한.권고치를 만족시키고 있다.

  • PDF

MAGNETIC PROPERTIES OF FERRITE CORES UNDER DC-BIASED FIELD

  • Fukunaga, H.;Masumoto, S.;Ohta, Y.;Kakehashi, H.;Ogasawara, H.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.606-609
    • /
    • 1995
  • Ferrite cores are often magnetized under DC-biased field because they have been intensively used in electronic circuits such as an inverter circuit and a switching regulator circuit. Thus we investigated the effects of DC-biased field on magnetic properties in the frequency range of DC-100kHz for two kinds of ferrite cores, TDK PC38 and TDK $H_{3}S$, which have different shapes of B-H loop from each other. The magnetic loss per cycle, W/f, in the $H_{3}S$ core decreased with increasing the strength of DC-biased field, although W/f in the PC38 core increased monotonically with DC-biased field. The observed decreasing tendency differs from the previous result for Si-Fe and ferrite cores, and can be attributed to decrease in eddy current loss as well as that in hysteresis loss.

  • PDF