• Title/Summary/Keyword: Magnetic

Search Result 22,053, Processing Time 0.046 seconds

Magnetic beads separation using a multi-layered microfluidic channel (다층구조의 미세유체채널을 이용한 자성입자 분리)

  • Lee, Hye-Lyn;Song, Suk-Heung;Jung, Hyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1685-1686
    • /
    • 2008
  • This paper presents the design and experiment results of a multi-layered microsystem for magnetic bead applications. The magneto-microfluidic device is designed for capable of separating magnetic beads. In the presence of the magnetic field, magnetic beads are attracted and moved to high gradient magnetic fields. A multi-layered microfluidic channel consists of top and bottom layers in order to separate magnetic beads in the vertical direction. Our channel is easily integrated magnetic cell sorter, especially on-chip microelectromagnet or permanent magnet device. Fast separation of magnetic beads in top and bottom channels can be used in high throughput screening to monitor the efficiency of blood and drug compounds.

  • PDF

Experimental Evaluation on Shear Modulus of MRE due to MRP Coating and Induced Current (Magnetic Reactive Particle 코팅 및 인가전류에 따른 Magnetorheological Elastomer 의 전단계수 측정)

  • Oh, Jae-Eung;Jeong, Un-Chang;Kim, Jin-Su;Yoon, Jung-Min;Roh, Jeong-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.927-929
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation). Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced current. As induced magnetic field intensity increased and coated with MRP, increment of MR effect was observed.

  • PDF

Methods for Determining the Quality of Magnetic Fluids

  • Chioran, Viorica;Chioran, Marius
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.197-201
    • /
    • 2013
  • This paper presents the conversion parameter values of the magnetic properties of magnetic fluids. These values were determined for three magnetic fluid samples containing particles with diameters between 30 ${\AA}$ and 170 ${\AA}$. The factors that may affect the value of this parameter (size of particle, magnetic properties, the presence of clusters and aggregates) are also studied. The determined values for the conversion parameter (${\gamma}$) are between 0.25 and 0.76 and the determined limit value is 0.8. Because many applications require magnetic fluids with the saturation magnetization as high as possible and the viscosity as low as possible [1], it has been considered necessary to determine this parameter which describes the quality of magnetic fluids.

Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances (가전기기에서 발생되는 극저주파 과도자계 예측기법 연구)

  • Ju, Mun-No;Yang, Kwang-Ho;Myung, Sung-Ho;Min, Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

Prediction of free magnetic energy stored in a solar active region via a power-law relation between free magnetic energy and emerged magnetic flux

  • Magara, Tetsuya
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2014
  • To estimate free magnetic energy stored in an active region is a key to the quantitative prediction of activity observed on the Sun. This energy is defined as an excess over the potential energy that is the lowest energy taken by a magnetic structure formed in the solar atmosphere including the solar corona. It is, however still difficult to derive the configuration of a coronal magnetic field only by observations, so we have to use some observable quantity to estimate free magnetic energy. Recently, by performing a coordinated series of three-dimensional magnetohydrodynamic simulations of an emerging flux tube that transfers intense magnetic flux to the solar atmosphere we have found an universal power-law relation between free magnetic energy and emerged magnetic flux, the latter of which is a possibly observed quantity. We further investigate what causes this relation through a comparison with a model of linear force-free field.

  • PDF

Efficient Search Method of Deperming Protocol for Magnetic Silence of Vessel

  • Kim, Jong-Wang;Kim, Sang-Hyun;Kim, Ji-ho;Lee, Hyang-Beom;Chung, Hyun-Ju
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • This research is proposed with the efficient searching method of deperming protocol for magnetic silence. The deperming protocol has been changed depending on the initial magnetic field, the final magnetic field, and the shot number, so deciding parameter is highly important. Therefore, in this paper, the value of the initial magnetic field is supposed to be fixed to that of the saturation field, and excluding the initial magnetic field in the variable, the deperming protocol has been analyzed depending on the final magnetic field and the change of the shot number. In the result of this experiment, the final magnetic field gets high performance to the reverse of the direction of the initial magnetization, and it is resulted that the shot number inverse proportion to the size of the final magnetic field.

Precision Magnetic Abrasive Polishing for Internal-face of STS304 Sanitary Pipe (STS304 위생용 파이프 내면의 정밀 자기연마)

  • Kim H.N.;Choi H.S.;Yu S.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.166-169
    • /
    • 2005
  • The magnetic polishing is the useful method to finish using magnetic power of magnet. This method is one of precision polishing techniques and has an aim of the clean. technology using for the pure of gas and inside of the sanitary pipe for transportation. The magnetic abrasive polishing method is not so common for machine that it is not spreaded widely. There are rarely researcher in this field because of non-effectiveness of magnetic abrasive. In this paper. We could have investigated into the changes of the movement of magnetic abrasive grain. In reference to this result, we could have made the experiment which is set under the condition of the magnetic flux density, polishing velocity according to the form of magnetic brush.

  • PDF

Recent R&D Trend in Magnetic Refrigeration at Room Temperature (실온 자기냉동의 최근 연구개발 동향)

  • Lee, Jong-Suk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.613-618
    • /
    • 2006
  • The 1st International Conference on Magnetic Refrigeration at Room Temperature was held at Montreux, Switzerland during September 27-30, 2005. The conference was the first of its kind to bring together about 140 scientists and engineers interested in magnetic refrigeration in one place. The magnetocaloric effect was discovered in 1881, however, magnetic refrigeration at room temperature was demonstrated to be viable in 1997 Since then, R&D efforts toward magnetic refrigeration have been on the rise around the world, in both areas of systems and materials. The conference reflected the recent R&D trend in magnetic refrigeration at room temperature, which includes the use of permanent magnet instead of superconductor magnet, switch from reciprocating to rotary magnetic refrigeration system, development of magnetic materials based on transition metal elements besides rare earth materials such as gadolinium(Gd).

  • PDF

The distribution of magnetic field strength in Orion A region

  • Hwang, Jihye;Kim, Jongsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.43.3-43.3
    • /
    • 2019
  • Magnetic fields play an important role in supporting molecular clouds against gravitational collapse. The measured magnetic field strengths in molecular clods enable us to see the effect of magnetic fields in star-forming regions. People have used the Chandrasekhar and Fermi (CF) method to estimate magnetic field strength from observational quantities of molecular cloud density, turbulent velocity and polarization angle dispersion. However, previous studies obtained just one magnetic field strength over the quite large region of a molecular cloud by using the CF method. We here suggest a way to estimate magnetic field strength distribution in Orion A region. We used 450 and 850-micron polarization data of James Clerk Maxwell Telescope (JCMT). Magnetic field strengths were estimated in two wavelengths with 4 pixel resolutions of 16, 20, 24 and 28". Through statistical analysis, we proved the difference of magnetic field strengths between two wavelengths were caused by the difference of their beam sizes. Additionally, we calculated the radii of curvature of polarization segments to select a best pixel resolution for estimating the magnetic field distribution. The pixel resolution should be larger than a radius of curvature. We selected that 20 or 24" pixel resolutions are good choices towards Orion A region.

  • PDF

X-ray scattering study on the electric field-induced interfacial magnetic anisotropy modulation at CoFeB / MgO interfaces

  • Song, Kyung Mee;Kim, Dong-Ok;Kim, Jae-Sung;Lee, Dong Ryeol;Choi, Jun Woo
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1212-1217
    • /
    • 2018
  • The electric field-induced modifications of magnetic anisotropy in CoFeB/MgO systems are studied using X-ray resonant magnetic scattering and magneto-optical Kerr effect. Voltage dependent changes of the magnetic anisotropy of -12.7 fJ/Vm and -8.32 fJ/Vm are observed for Ta/CoFeB/MgO and Hf/CoFeB/MgO systems, respectively. This implies that the interfacial perpendicular magnetic anisotropy is reduced (enhanced) when electron density is increased (decreased). X-ray resonant magnetic scattering measurements reveal that the small in-plane magnetic component of the remanent state of CoFeB/MgO systems with weak magnetic anisotropy changes depending on the applied voltage leading to modification of the magnetic anisotropy at the CoFeB/MgO interface.