• 제목/요약/키워드: Magnet design

검색결과 1,401건 처리시간 0.028초

기동과 효율을 고려한 단상 LSPM의 베리어 설계에 관한 연구 (A study on the Barrier Design Considering Start performance and Efficiency in Single-phase Line-start Permanent Magnet Motor)

  • 김원호;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.19-21
    • /
    • 2008
  • The purpose of this paper is the optimal design of a single-phase LSPM(Line-Start Permanent Magnet Motor). A single-phase LSPM has a permanent magnet in the rotor that is same as induction motor. For that reason, magnet is operated by breaking torque in starting region and alignment torque in driving region. Therefore, we need the design process considering the trade-off relationship. In this paper, we propose the design process of a single-phase LSPM for a high starting torque and efficiency with equivalent circuit and FEM. And we use Taguchi Method for considering tolerance in manufacture. Finally, we compared the LSPM that is designed in this paper and conventional induction motor.

  • PDF

능동 차폐 MRI 초전도 자석에 대한 최적 설계 방법 (Optimal Design Method for an Actively Shielded MRI Superconducting Magnet)

  • 이광호;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.421-430
    • /
    • 2000
  • This paper describes an optimal design method which is applied a weighted least square (WLS) method for Magnetic Resonance Imaging (MRI) system. An optimal design approach is presented for a homogeneity superconducting magnet with the superconducting active shield especially for a magnetic resonance imaging system. The WLS is used to obtain the optimal configurations using the least amount and minimum volume of conductor, exhibiting the smallest level of field inhomogeneity and resulting in the least level of stray field. The proposed model is used to design a multiple-shield configuration for a 1.5 T MRI magnet. The field homogeneity is required less than 5 gauss stray field contour within 4m axially and 3m radially from origin. The designed magnet with the actively magnetic shielding coil out of main coils is analyzed by FEM and theoretical analysis method, investigated the field homogeneity.

  • PDF

단상 유도형 동기전동기의 파라미터 변화에 따른 동특성 해석 (Dynamic Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor by Parameter Variation)

  • 오세영;정대성;임승빈;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.763-764
    • /
    • 2006
  • In this paper, optimized model was designed for the starting characteristic of the Single-Phase Line-Start Permanent Magnet Synchronous Motor by using the Design of Experiment. A field pole angle, thickness and distance from center axis of permanent magnet were selected as design factor. We executed the transient state characteristic analysis of 8 test models. The transient state characteristic analysis was executed by using the 2 dimensional Finite Element Method and the Time Difference Method. We checked the fact that the selected design factor affected starting characteristic of the Line-Start Permanent Magnet Synchronous Motor. Depend on this result we found the optimized design point by using the response optimization.

  • PDF

Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

집중권을 시행한 영구자석 매입형 동기전동기의 철손 저감 (Core-loss reduction on PM for IPMSM with concentrated winding)

  • 이형우;박찬배;이병송;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1832-1837
    • /
    • 2011
  • This paper presents the optimal permanent magnet shape on the rotor of an interior permanent magnet motor to reduce the core losses and improve the performance. As permanent magnet has conductivity inherently, it causes huge amount of eddy current losses by the slot harmonics with concentrated winding. This loss is roughly 100 times larger than that of distributed winding in high speed operation and it cannot be ignored, especially on traction motors. Each eddy current loss on permanent magnet has been investigated in detail by using FEM(Finite Element Method) instead of EMCNM(Equivalent Magnetic Circuit Network Method) in order to consider saturation and non-linear magnetic property. Simulation-based DOE(Design Of Experiment) is also applied to avoid large number of analyses according to each design parameter and consider expected interactions among parameters. Consequently, the optimal design to reduce the core loss on the permanent magnet while maintaining or improving motor performance is proposed by an optimization algorithm using regression equation derived and lastly, the core loss reduction on the proposed shape of the permanent magnet is verified by FEM.

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

자석을 이용한 유압직동형 릴리이프 밸브에 관한 연구 (Study on a Magnet-Coupleed Hydraulic Direct Relief Valve)

  • 조규식;이정오
    • 대한기계학회논문집
    • /
    • 제1권2호
    • /
    • pp.65-72
    • /
    • 1977
  • Major problems in the design and use of refief valve are (a) chattering because of instability, (b) excessive pressure differential which makes the valves crack far below maximum pressure diminishing useful flow in the system. In this study, A magnet-coupled relief valve is investigated theoretically and experimentally in order to improve the performance of a conventional direct type reliefvalve. A theory is developed to predict the performance, response, and stability of the magnet-coupled valve taking into account the delivery line response. In the experiment, a typical magnet-coupled relief valve is designed on the basis of the analytical results; the discharge rates are measured varying the supply pressure, and both the pressure-time curves and valve displacament-time curves are recorded providing the supply pressures greater than the setting pressure. The measured override characteristic curves are then compared with those of conventional pilot type and direct type releif valves. It is showm that the excessive pressure differential of a magnet-coupled relief valve becomes less than that of a conventional direct type valve. It is also shown that the most important chatacteristic of a magnet-coupled relief valve is to eliminate valve chattering due to instability regardless of the magnitude of setting pressures and discharge rates, which suggests wide applications of the idea of the use of a magnet in the design of hydraulic valves.

Harmonic analysis and field quality improvement of an HTS quadrupole magnet for a heavy ion accelerator

  • Zhang, Zhan;Wei, Shaoqing;Lee, Sangjin;Jo, Hyun Chul;Kim, Do Gyun;Kim, Jongwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.21-24
    • /
    • 2016
  • In recent years, the iron-dominated high-temperature superconductor (HTS) quadrupole magnets are being developed for heavy ion accelerators. Field analyses for iron-dominated quadrupole magnets were based on the normal-conducting (NC) quadrupole magnet early in the development for accelerators. Some conclusions are still in use today. However, the magnetic field of iron-dominated HTS quadrupole magnets cannot fully follow these conclusions. This study established an HTS quadrupole magnet model and an NC quadrupole magnet model, respectively. The harmonic characteristics of two magnets were analyzed and compared. According to the comparison, the conventional iron-dominated quadrupole magnets can be designed for maximum field gradient; the HTS quadrupole magnet, however, should be considered with varying field gradient. Finally, the HTS quadrupole magnet was designed for the changing field gradient. The field quality of the design was improved comparing with the result of the previous study. The new design for the HTS quadrupole magnet has been suggested.

오버행 효과를 고려한 단상 유도동기전동기의 특성해석 및 설계 (Analysis and Design of the Single-phase Line Start Permanent Magnet Motor Considering Overhang Effect)

  • 강한별;김병택;백수황;김홍석;권병일
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.49-56
    • /
    • 2009
  • This paper shows the characteristic analysis of single-phase line start permanent magnet (LSPM) motors considering the overhang structure. To achieve the low-cost design of an LSPM motor, the overhang structure is adapted for the rotor with a constraint of a fixed magnet volume. To obtain the dynamic and steady performance of the motor, the circuit parameters are extracted using the 3D-static FEM(Finite Element Method) and the d-q equivalent circuit is used. The performance of the model with overhang is compared with the conventional model without overhang on the condition that both models have a fixed volume for the permanent magnet.