• Title/Summary/Keyword: Magnet Field

Search Result 937, Processing Time 0.025 seconds

A Study of Power Perception between Supplier and Retail Buyer of Agricultural Products (농산물공급자와 대형소매업체 바이어간의 상호 파워 인식에 대한 연구)

  • 서성무;이은정
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2003.02a
    • /
    • pp.123-166
    • /
    • 2003
  • Marketing channel is recognized as one of the society systems which have the character of functional organization. These organizations are related to each other for specialized and cooperative work. Channel members in distribution channel are striving to accomplish exchange through reciprocal action. Thus channel members exercise their power to take better position in exchange. There will be struggling between members about satisfaction and conflict during this power exercise. Now a days, buyers use more harsh power as large retail firms are increasing. This phenomenon is occurring in the distribution channel. However, there will be different phenomenon in case of agricultural products. Not like industrial product suppliers, agricultural product suppliers have various supply channels and many agricultural products are seasonal. It has also unstable amount supplies. There should be differentiated marketing in agricultural products. Relatively weaker powered suppliers have to strengthen comparative factors and also have to be technically specialized through assessed experience in order to establish strong product sales chain. Making a brand of agricultural product would be also a good idea to increase the product comparability. Channel members need to be recognized their specialized functions in order to make balanced distribution channel. There have to be conversion of concept of relation between suppliers and buyers from subordinate relationship to cooperative relationship.

  • PDF

Plasma Sources for Production of High Flux Particle Beams in Hyperthermal Energy Range (하이퍼써멀 에너지 영역에서 높은 플럭스 입자빔 생성을 위한 플라즈마 발생원)

  • Yoo, S.J.;Kim, S.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.186-196
    • /
    • 2009
  • Since it is difficult to extract a high flux ion beam directly at an energy of hyperthermal range ($1{\sim}100\;eV$), especially, lower than 50 eV, the ions should be neutralized into neutral particles and extracted as a neutral beam. A plasma source required to generate and efficiently transport high flux hyperthermal neutral beams should be easily scaled up and produce a high ion density (${\ge}10^{11}\;cm^{-3}$) even at a low working pressure (${\le}$ 0.3 mTorr). It is suggested that the required plasma source can be realized by Electron Cyclotron Resonance (ECR) plasmas with diverse magnetic field configurations of permanent magnets such as a planar ECR plasma source with magnetron field configuration and cylindrical one with axial magnetic fields produced by permanent magnet arrays around chamber wall. In both case of the ECR sources, the electron confinement is based on the simple mirror field structure and efficiently enhanced by electron drifts for producing the high density plasma even at the low pressure.

Study of Magnetic Field Shielded Sputtering Process as a Room Temperature High Quality ITO Thin Film Deposition Process

  • Lee, Jun-Young;Jang, Yun-Sung;Lee, You-Jong;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.288-289
    • /
    • 2011
  • Indium Tin Oxide (ITO) is a typical highly Transparent Conductive Oxide (TCO) currently used as a transparent electrode material. Most widely used deposition method is the sputtering process for ITO film deposition because it has a high deposition rate, allows accurate control of the film thickness and easy deposition process and high electrical/optical properties. However, to apply high quality ITO thin film in a flexible microelectronic device using a plastic substrate, conventional DC magnetron sputtering (DMS) processed ITO thin film is not suitable because it needs a high temperature thermal annealing process to obtain high optical transmittance and low resistivity, while the generally plastic substrates has low glass transition temperatures. In the room temperature sputtering process, the electrical property degradation of ITO thin film is caused by negative oxygen ions effect. This high energy negative oxygen ions(about over 100eV) can be critical physical bombardment damages against the formation of the ITO thin film, and this damage does not recover in the room temperature process that does not offer thermal annealing. Hence new ITO deposition process that can provide the high electrical/optical properties of the ITO film at room temperature is needed. To solve these limitations we develop the Magnetic Field Shielded Sputtering (MFSS) system. The MFSS is based on DMS and it has the plasma limiter, which compose the permanent magnet array (Fig.1). During the ITO thin film deposition in the MFSS process, the electrons in the plasma are trapped by the magnetic field at the plasma limiters. The plasma limiter, which has a negative potential in the MFSS process, prevents to the damage by negative oxygen ions bombardment, and increases the heat(-) up effect by the Ar ions in the bulk plasma. Fig. 2. shows the electrical properties of the MFSS ITO thin film and DMS ITO thin film at room temperature. With the increase of the sputtering pressure, the resistivity of DMS ITO increases. On the other hand, the resistivity of the MFSS ITO slightly increases and becomes lower than that of the DMS ITO at all sputtering pressures. The lowest resistivity of the DMS ITO is $1.0{\times}10-3{\Omega}{\cdot}cm$ and that of the MFSS ITO is $4.5{\times}10-4{\Omega}{\cdot}cm$. This resistivity difference is caused by the carrier mobility. The carrier mobility of the MFSS ITO is 40 $cm^2/V{\cdot}s$, which is significantly higher than that of the DMS ITO (10 $cm^2/V{\cdot}s$). The low resistivity and high carrier mobility of the MFSS ITO are due to the magnetic field shielded effect. In addition, although not shown in this paper, the roughness of the MFSS ITO thin film is lower than that of the DMS ITO thin film, and TEM, XRD and XPS analysis of the MFSS ITO show the nano-crystalline structure. As a result, the MFSS process can effectively prevent to the high energy negative oxygen ions bombardment and supply activation energies by accelerating Ar ions in the plasma; therefore, high quality ITO can be deposited at room temperature.

  • PDF

Axial Pressing Method Using Pulse Magnetizing Field for the Preparation of Nd-Ee-B Sintered Magnets (펄스자장을 이용한 고이방화 Nd-Fe-B자석의 종축자장성형방법)

  • Kim, Dong-Hwan;Kang, Byung-Kil;Jang, Dong-Youl;Kim, Andrew S.;Kim, Sang-Myun;Jang, T.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.4
    • /
    • pp.182-186
    • /
    • 2003
  • A new axial pressing method using pulse magnetizing field was studied to improve the remanence of Nd-Fe-B sintered magnets. In order to make near-net shape green compacts of butterfly, disk, or coin magnets, conventional axial-type pressing has been normally used. However, compared to the transverse-type pressing, it is not possible to obtain higher remanence by this method because the magnetic alignment of powder begins to deteriorate when the density of green compacts increases over a critical value. On the other hand, we found that an axial pressing under pulse magnetizing field was very effective to increase the degree of magnetic alignment of powder, yielding remanences even higher than those obtained by the transverse pressing. In this study, it was revealed that appropriate tapping density and how to apply pulse magnetic held were important to improve the grain alignment and thus remanence of Nd-Fe-B sintered magnet.

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

A Study of the Vibration Characteristics of a Haptic Vibrator for Horizontal and Vertical Magnetization (수평 및 수직 착자에 대한 햅틱 진동자의 진동특성에 관한 연구)

  • Ko, Dong Shin;Hur, Deog Jae;Park, Tae Won;Lee, Jai Hyuk;Lee, Sung Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.415-421
    • /
    • 2015
  • This paper describes the study of the design procedure for the step-by-step setup parameters and of the magnetizing method for performance and size reduction in the development of a haptic vibrator. The study of magnetization was accomplished by comparing the electromagnetic force in accordance with the horizontal and the vertical magnetization. The theoretical results indicated that the horizontal magnetization resulted in a better performance. The systematic design of a step-by-step procedure for establishing the design parameters was verified by testing the characteristics of the fabricated prototype product. The vibration response function analysis and electric field analysis were processed by decoupling of the analytical method, and these were determined to be in good agreement with the test results. The design parameters to contributing to the product reliability included the spring height, the welding position, and the coil position. The sensitivity of the electromagnetic field and the performance change were analyzed based on the design parameters. As a result, we proposed a design method to implement a reliability-based, high performance haptic vibrator.

Development of EPICS-IOC Measuring Magnetic Field at A/Q separator for Separating Specific Ions (가속이온 분리를 위한 A/Q Separator에서 자장측정용 EPICS-IOC 개발)

  • Lee, Su-Yeong;Yim, Hee-Joong;Kim, Jae-Hong;Mun, Jun-Yeong;Park, Mi-Jeong;Lee, Sang-Il;Lee, Dong-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.91-98
    • /
    • 2021
  • The installation and performance test of the ISOL (Isotope Separation On Line) system for the generation and separation of Rare Isotopes (RI) beams is in progress at the Rare Isotope Science Project (RISP), Institute for Basic Science (IBS). The various RI beams generated by the ISOL target/ion source go through the beam lines and separators, and only the RI beam desired by the user is selected and transmitted to the superconducting linear accelerator at the downstream of the ISOL. In the ISOL system, two separators are installed to separate a specific RI beam, and control is performed by the Experimental Physics and Industrial Control System (EPICS). In this study, an EPICS IOC (Input-Output Control) was developed to measure the magnetic field of a dipole magnet for mass separation of a multivalent (n+) RI beam in the A/Q separator, which is one of the ISOL RI beam separators. The operational stability of the A/Q separator was tested through a magnetic field measurement using a Hall probe.

Effect of Strip-cast Conditions on the Formation of Microstructures in Nd-Fe-B alloys (Strip-cast 조건이 Nd-Fe-B 합금의 미세조직 형성에 미치는 영향)

  • Lee, D.H.;Jang, T.S.;Kim, D.H.;Kim, Andrew S.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • In order to improve the microstructure of the strip cast Nd-Fe-B alloys that are frequently used for production of high energy sintered magnets, influence of various strip casting conditions on the microstructure and phase formation and distribution were investigated. Nd-Fe-B strips consisting of microstructures suitable for preparation of high energy sintered magnets could be obtained when the wheel speed was below 5 m/s. The compositional limit that can avoid the crystallization of free iron in the as-cast state was estimated to be Nd$\_$14/Fe$\_$79/B$\_$7/. Regardless of the compositional variation, <001> preferred orientation of Nd$_2$Fe$\_$14/B normal to the strip surface was always occurred below 5 m/s, which would eventually enhance the grain alignment during pressing the powder under a magnetic field. While the coercivity of the strip cast alloys increased with the increase of the wheel speed, mainly due to the refinement of Nd$_2$Fe$\_$14/B grains, it decreased with the reduction of Nd content in the alloy composition as the formation of free iron increased.

실험 대상에 따른 다양한 Birdcage Resonator의 개발

  • 이정우;윤성익;최보영;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.47-47
    • /
    • 2003
  • Abstract: RF Birdcage Resonator는 높은 자장 균질성과 신호 대 잡음비의 특성이 좋음으로 인해 MRI와 MRS 연구에 보편적으로 사용되고 있다. 본 연구는 인체를 비롯한 동물실험을 위한 다양한 실험대상에 따라 코일의 크기를 예측하여 Birdcage Resonator를 개발하였다. Unloaded와 Loaded 상태에서의 전기적인 성향을 Lumped Element Circuit Theory를 따라 일반적인 분석을 하였을 뿐 아니라 실제적인 실험을 통한 분석도 하였다. Introduction: Birdcage Resonator 는 자장 균일성이 뛰어나고 신호대잡음비가 좋아 Magnetic Resonance Imaging과 Spectroscopy에 유용하게 사용되어지고 있다. 이 연구에서는 실험대상에 따른 여러 가지의 Birdcage Resonator를 개발하기 위해 Lumped Element Circuit Theory를 사용한 일반적인 이론적 방법론을 이용하여 코일을 분석하였을 뿐 아니라 실제 제작한 후 실험을 통한 실질적인 영상분석도 병행하여 진행하였다. Method: 실질적인 개발에 앞서 Lumped Element Circuit Theory를 통해 이론적인 분석으로부터 나온 여러 parameter들을 정리하였다. 제작 후 실험적인 분석은 Network Analyzer (HP 4195A, 미국)를 통한 1차적인 분석을 한 후 최종적으로 3T MRI 장비 (메디너스, 한국)에서 수행하였다. 제작된 Birdcage Resonator의 종류는 기본적으로 Low-Pass Filter를 적용한 12-column 구조이다. 각각의 직경과 element의 길이는 다음과 같다. 1) 직경 13cm, element의 길이 22cm, 2) 직경 15cm, element의 길이 22cm, 3) 직경 17 cm, element의 길이 25cm. Result and Discussion: 여러 parameter들을 이론적으로 계산하여 실제 Birdcage Resonator를 제작하여 실험적인 분석을 한 결과 많은 차이가 있음을 알 수 있었다. 그 이유는 이론적인 계산에서는 생각되지 않았던 요인들이 실제 제작에 있어서는 많은 영향을 미쳤기 때문인 것이다. Network Analyzer를 통한 1차적인 분석 후에도 실제의 Magnet Field내에서 또 다시 차이가 나는 것 또한 같은 이유에서이다. 그러므로 Birdcage Resonator 제작에 있어서 이러한 여러 요인들을 충분히 고려하여야 할 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002) 지원아래 수행되었다.

  • PDF

Control of Automatic Pipe Cutting Robot with Magnet Binder Using Learning Controller (반복학습제어기를 이용한 자석식 자동 파이프 절단 로봇의 제어)

  • Lee Sung-Whan;Kim Gook-Hwan;Rhim Sung-Soo;Lee Soon-Geul
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.541-546
    • /
    • 2005
  • Tracking control of an automatic pipe cutting robot (APCROMB) is studied. Using magnetic force APCROMB, which is designed and developed in Kyung Hee University, binds itself to the pipe and executes unmanned cutting process. The gravity effect on the movement of APCROMB varies as it rotates around the cylindrical pipe laid in the gravitational field. To maintain a constant velocity and consistent cutting performance against the varying gravitational effect, the authors adopt a multi-rate repetitive learning controller (MRLC), which learns the required effort to cancel the repetitive tracking errors caused by nonlinear effect. In addition to the varying gravity effect other types of nonlinear disturbances including backlash in the driving system and the slip between the wheels of APCROMB and the pipe also cause degradation in the cutting process. In order to identify those nonlinear disturbances the position estimation based on the encoder attached at the motor is not good enough. To identify the absolute angular position of APCROMB the authors propose the angular position estimation based on the signals from a MEMS-type two-axis accelerometer mounted on APCROMB. The tracking performances of APCROMB with a MRLC using the encoder-based position estimation is experimentally measured and results are shown. Also the difference between the encoder-based angular displacement measurement and the accelerometerbased angular displacement measurement is included.

  • PDF