• 제목/요약/키워드: Magnet Field

검색결과 937건 처리시간 0.021초

Magnetic field characteristics from HTS quadruple magnet of in-flight separator for a heavy ion accelerator

  • Zhang, Zhan;Lee, Sangjin;Jo, Hyun Chul;Kim, Do Gyun;Kim, Jongwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.23-27
    • /
    • 2015
  • Quadruple magnet is an essential component for the accelerator, and the field uniformity in the good field region reflects the quality of quadruple magnet. In this paper, the total magnetic field B was separated into the coil-induced magnetic field $B_s$ and the iron-induced magnetic field $B_c$ to explain why the total magnetic field B has some inhomogeneity. Using Fourier analysis, harmonic components of $B_s$, $B_c$ and B have been analyzed at good field region, respectively. The harmonics of multipole magnet and Fourier analysis are helpful to show the uniformity of magnetic field. Several geometries of yoke and coils were defined to analyze the effect on field uniformity of an HTS quadruple magnet. By the analysis, it was found that the sixth harmonics which is the main factor of field inhomogeneity can be reduced to zero. It means that the sixth harmonics of the magnetic field B can be removed by adjusting the geometry of the magnet pole and the position of coils. We expect that this result can effectively improve the uniformity of an HTS quadruple magnet.

Improved Method for Calculating Magnetic Field of Surface-Mounted Permanent Magnet Machines Accounting for Slots and Eccentric Magnet Pole

  • Zhou, Yu;Li, Huaishu;Wang, Wei;Cao, Qing;Zhou, Shi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1025-1034
    • /
    • 2015
  • This paper presented an improved analytical method for calculating the open-circuit magnetic field in the surface-mounted permanent magnet machines accounting for slots and eccentric magnet pole. Magnetic field produced by radial and parallel permanent magnet is equivalent to that produced by surface current according to equivalent surface-current method of permanent magnet. The model is divided into two types of subdomains. The field solution of each subdomain is obtained by applying the interface and boundary conditions. The magnet field produced by equivalent surface current is superposed according to superposition principle of vector potential. The investigation shows harmonic contents of radial flux density can be reduced a lot by changing eccentric distance of eccentric magnet poles compared with conventional surface-mounted permanent-magnet machines with concentric magnet poles. The FE(finite element) results confirm the validity of the analytical results with the proposed model.

초등학교 예비교사들의 자석에 관한 이해도 조사 (An Invesitgation of Pre-service Teachers Understandings on Magnet)

  • 이형철;정승호
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제23권2호
    • /
    • pp.141-151
    • /
    • 2004
  • Pre-service teachers' understandings on magnet was investigated through the questionnaire method. The questionnaire was composed of 17 questions about the strength of magnet, the magnetized object and the direction of magnetic field around magnet. In this investigation study, 225 pre-service teachers were selected through random sampling method, who were sophomores in a National University of Education. The formation rate of the scientific conceptions on the strength of magnet was 30.3% and that on the direction of magnetic field around magnet was 53.9%. The average formation rate of scientific conception of all questions on magnet was 44.13%, which doesn't seem to be high as expected. It shows that many of subjects of the questionnaire don't understand fully the concept of moleclar magnet model and the superposition effects of magnetic field around magnet. The formation rate of the scientific conception on magnet of females who took courses in sciences in high school were higher than that of females who took courses in arts in high school, which had meaningful difference (p<.05).

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

고온 초전도 마그넷의 선재에서 발생되는 자장과 전계 해석 (Magnetic Field and Electric Field Generated in an HTS Tape of a High Temperature Superconducting Magnet)

  • 김영민;구명환;차귀수;전창완;백경호
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.753-758
    • /
    • 2011
  • Magnetic field and Electric field of High Temperature Superconducting magnet are very important to analysis of superconducting magnet. The maximum perpendicular magnetic field was applied to the outermost pancake windings. The critical current of all the magnet windings is limited by the critical current of the outermost pancake windings. The E-J relation was used to determine the critical current, and an evolution s trategy was adopted for the optimization of gap length between each pancake windins. The results of calculations show that the critical current and the central magnetic field and uniformity increased by 82.6% and 31.6% and 50.8%, respectively, for a magnet consisting of ten pancake windings. This paper did an analysis the cause of increase the critical current and central magnetic field and uniformity in no gap and optimal gap model.

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

능동차폐형 초전도 MRI 마그네트의 설계 (A design of actively shielded superconducting MRI magnet)

  • 진홍범;류강식;송준태
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.24-29
    • /
    • 1996
  • Magnetic field theories for the design of highly homogeneous magnet are introduced and a nonlinear optimization method for the design of actively shielded superconducting magnet is presented. The presented design method can optimize both main coil and shielding coil simultaneously by setting constraints on stray field intensity at a specified distance from the magnet center. A 2-Tesla actively shielded superconducting magnet, with 90cm bore diameter, is designed using the presented method. The field homogeneity is 2ppm/30cm DSV and the 5 gauss stray field contour is within 4m axially and 3m radially from the magnet center. (author)., 7 refs., 6 figs., 3 tabs.

  • PDF

Electromagnetic design study of a 7 T 320 mm high-temperature superconducting MRI magnet with multi-width technique incorporated

  • Jang, Won Seok;Kim, Geonyoung;Choi, Kibum;Park, Jeonghwan;Bang, Jeseok;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.30-34
    • /
    • 2021
  • Superconducting magnets have paved the way for opening new horizons in designing an electromagnet of a high field magnetic resonance imaging (MRI) device. In the first phase of the superconducting MRI magnet era, low-temperature superconductor (LTS) has played a key role in constructing the main magnet of an MRI device. The highest magnetic resonance (MR) field of 11.7 T was indeed reached using LTS, which is generated by the well-known Iseult project. However, as the limit of current carrying capacity and mechanical robustness under a high field environment is revealed, it is widely believed that commercial LTS wires would be challenging to manufacture a high field (>10 T) MRI magnet. As a result, high-temperature superconductor together with the conducting cooling approach has been spotlighted as a promising alternative to the conventional LTS. In 2020, the Korean government launched a national project to develop an HTS magnet for a high field MRI magnet as an extent of this interest. We have performed a design study of a 7 T 320 mm winding bore HTS MRI magnet, which may be the ultimate goal of this project. Thus, in this paper, design study results are provided. Electromagnetic design and analysis were performed considering the requirements of central magnetic field and spatial field uniformity.

원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교 (Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging)

  • 김용권;현정호;서증훈;김혁기;오창현
    • 전자공학회논문지SC
    • /
    • 제48권6호
    • /
    • pp.57-62
    • /
    • 2011
  • 본 논문에서는 초전도 자석의 자장 균일도를 개선하기 위한 방법으로 3가지 형태의 magnet 모델을 제안하고 각각의 자석 형태에 대하여 같은 세기의 자장을 (Magnet field strength) 가질 경우에 최소전력 방식으로 최적화된 전류 분포에 해당하는 coil wire의 길이, 그리고 해당 조건에서의 자장의 불균일도를 시뮬레이션을 통하여 비교, 분석하였다. 구성된 3가지 magnet type을 동일한 조건 (계산 점의 개수 18개, 20cm DSV)에 대해서 wire길이와 main field inhomogeneity를 비교하였으며, 이러한 시뮬레이션 결과를 통하여 얻을 수 있는 결론은 계산점의 수가 적을수록 wire의 길이는 짧아지나 field inhomogeneity는 높아진다는 것이다. 즉, Magnet shim을 수행할 경우 계산점을 줄이는 방법으로는 짧은 wire의 길이와 main field homogeneity를 동시에 만족하도록 최적화 하는 것이 거의 불가능함을 의미하는 것이다. 그러나 DSV를 줄였을 경우에 계산점을 줄였을 때에 비해 우수한 결과 값을 얻을 수 있었다. 결론적으로 공간적으로 개방되어 있는 magnet model의 경우 계산점을 줄여 shimming을 진행할 경우 동일한 imaging region의 크기에 대해 더 많은 전류(또는 wire 길이)가 필요하고 field 균일도도 떨어졌으나 작은 ROI를 대상으로 영상을 얻는 경우 유용하게 사용될 수 있다.

Effects of Air Gap on HTS Magnet Consisting of Double Pancake Windings

  • Ku, Myung-Hwan;Kang, Myung-Hun;Kim, Young-Min;Lee, Hee-Joon;Cha, Guee-Soo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권4호
    • /
    • pp.33-36
    • /
    • 2009
  • An air gap between the pancake windings was provided in this paper to increase the central magnetic field of a high temperature superconducting (HTS) magnet consisting of pancake windings. Unlike the LTS magnet, providing an air gap between the pancake windings increases the central magnetic field of a HTS magnet. Furthermore, the uniformity of the magnetic field near the center of the magnet increased because the pancake windings spread out in wider area. Effects of the air gap on the central magnetic field of an HTS magnet was described in this paper, Calculation of the critical current was carried out by using E-J relation of the HTS wire and the optimization technique was adopted to obtain the appropriate critical current which could maximize the central magnetic field. Pancake windings with BSCCO-2223 HTS wire were wound on glass epoxy bobbin. 6 double pancake windings with 200 turns were used to construct a HTS magnet. Characteristics of the HTS magnet including the central magnetic field and the uniformity of the magnetic field were measured and compared with the results of calculation.