• Title/Summary/Keyword: Maddox rod test

Search Result 7, Processing Time 0.029 seconds

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

Effect of Visual Sensory Improvement by Amblyopia Treatment on Improvement of Ocular Functions (약시 치료에 의한 시감각 개선이 안기능 향상에 미치는 효과)

  • Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.551-555
    • /
    • 2014
  • Purpose: This study is to investigate if the improvement of visual sensory (VS) by amblyopia treatment affects the ocular functions in refractive errors, accommodative errors and phoria at distance and near. Methods: 10 subjects (17 eyes, mean age of $10.7{\pm}2.9$ years) who treated amblyopia completely, were participated for this study. Refractive errors, accommodative errors, and distance and near phoria were compared between before and after treatments of amblyopia. Refractive errors and accommodative errors at 40 cm were measured using openfield auto-refractor (NVision-5001, Shin Nippon, Japan) and using monocular estimated method (MEM) respectively. Phoria was determined at 3 m for distance and at 40 cm for near using Howell phoria card, cover test or Maddox rod. Results: Mean corrected visual acuity (CVA) significantly increased from $0.46{\pm}0.11$ (decimal notation) for before amblyopia treatment to a level of $1.03{\pm}0.13$ for after amblyopia treatment (p < 0.001). For spherical refractive error, hyperopia significantly decreased from $+2.29{\pm}0.86D$ to a level of $+1.1{\pm}2.38D$ (p < 0.05) but astigmatism did not significantly change; $-1.80{\pm}1.41D$ for before treatment and $-1.65{\pm}1.30D$D for after treatment (p > 0.05). Accommodative error significantly decreased from accommodative lag of $+1.1{\pm}0.75D$ to a level of $+0.5{\pm}0.59D$ (accommodative lag) (p < 0.05). Distance phoria significantly changed from eso $2.9{\pm}6.17PD$ (prism diopters) to a level of eso $0.2{\pm}3.49PD$ (p < 0.05), and near phoria also significantly changed from eso $0.4{\pm}2.32PD$ to level of exo $2{\pm}4.9PD$ (p < 0.05). There was a high correlation (r = 0.88, p < 0.001) between improvement of visual acuity and decrease of accommodative lag. Conclusions: Hyperopic refractive error decreased with improvement of CVA or VS by amblyopia treatment. And the improvement of VS by amblyopia treatment also improved accommodative error, and changed phoria coupled with accommodation.