• Title/Summary/Keyword: Machine to machine

Search Result 20,084, Processing Time 0.05 seconds

COMPARISON OF COMPRESSIVE STRENGTH AND SURFACE MICROHARDNESS BETWEEN FLOWABLE COMPOSITE RESIN AND GIOMER (유동성 자이오머와 복합 레진의 압축 강도 및 표면 미세 경도 비교)

  • Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.383-388
    • /
    • 2012
  • The aim of this study was to compare the compressive strength and the surface microhardness of Beautifil flow (Shofu, Kyoto, Japan) with $Filtek^{TM}$ Z350, Z350XT (3M ESPE, USA). Fifteen specimens from each material were fabricated for testing. Compressive strength was measured by using a universal testing machine at a crosshead speed of 1 mm/min. Surface microhardness values were measured by using Vickers hardness tester under 4.9 N load and 10 seconds dwelling time. The compressive strength of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $218.7{\pm}18.4$ MPa and Group 1 $Filtek^{TM}$ Z350 was $205.5{\pm}27.1$ MPa. Group 3 Beautifil flow F00 was $176.5{\pm}30.3$ MPa, and Group 4 Beautifil flow F10 was $173.4{\pm}26.2$ MPa. The compressive strength of Group 2 is higher than Group 3 and 4 (p < 0.05). The surface microhardness of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $39.1{\pm}2.1$ and Group 4 Beautifil flow F10 was $27.9{\pm}1.8$. And Group 3 Beautifil flow F00 was $23.1{\pm}1.1$, Group 1 $Filtek^{TM}$ Z350 was $20.4{\pm}0.9$. There was a statistical significant difference in surface microhardness between all groups (p < 0.05). In conclusion, the compressive strength of giomer was below the level of flowable composite resin. However, the surface microhardness of giomer is comparable to that of flowable composite resin. Giomer would be the good alternative to composite resin, if there is improvement of the compressive strength of giomer.

A Study of the Accidents of the Residents in a Rural Area (일개 보건진료소 사업 지역의 사고조사)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Kim, Seok-Beom;Kim, Chang-Yoon;Lee, Ok-Keum
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.174-184
    • /
    • 1991
  • To determine the incidence rate of accidents and its associated factors, a prospective survey was carried out in a rural area of a total of 1,360 residents for 1 year from January 1 to December 31, 1988 in Shin-am Ri, Jungdong Myun, Sangju Kun, Kyungpook Province. Data for accidents were collected by the community health practitioner who is working at Primary Health Post in Shin-am Ri. A total number of accident cases was 85 among 1,360 persons during one year study period, and annual incidence rate was 62.5 per 1,000 persons. The highest incidence rate of accident was observed in the age group of 30-39 was 179.8. The incidence rate of accident in male was 86.5 which was about 2 times that in female. In male, the highest incidence rate was seen in 30-39 age group and in female, 60-69 age group. The highest incidence rate of accident was observed in spring(29.4%) and summer(29.4%), and the lowest in fall(17.7%). The highest incidence rate of accident was observed in Friday(24.5%) by day of week, and between 9 a.m. to 12 a.m. by time zone. The most frequent use of medical facilities was Primary Health Post(51.8%) and the next was clinic(38.8%). Mean duration of treatment was 9.8 days. The accident occured in the room and kitchen(23.5%), in the yard and barn(23.5%), on the road(22.4%). and in the rice field and dry field(20.0%). The causes of accident were motor vehicle accident(20.0%), piercing or cutting(20.0%), collision or fighting(12.9%), and poisoning(11.8%) in order of frequency. The most common type of injury was open wound which was 43.5%. The most common tool of accident was farm machine which was 23.5%. The most common injuried part of body was extremity(55.3%).

  • PDF

CORRELATIONS BETWEEN ORBICULARIS ORIS AND MENTALIS MUSCLE ACTIVITY AND CRANIOFACIAL MORPHOLOGY IN NORMAL OCCLUSION AND CLASS III MALOCCLUSION (정상교합자와 3급 부정교합자에서 구륜근과 턱끝근의 활성과 안면골격 사이의 상관성에 관한 연구)

  • Chang, Chun Sil;Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.253-271
    • /
    • 1992
  • The purpose of this study was to investigate the difference of EMG activity of the Orbicularis oris and Mentalis muscle between normal occlusion and class III malocclusion group during various lip position and to find out whether any correlations exist between the muscular activity and craniofacial morphology. In this study, 50 subjects with a mean age of 22.9 Years (range 20.0-26.0) were investigated (25 subjects were normal occlusion, and 25 subjects were class III malocclusion). EMG data were recorded from the Orbicularis oris and Mentalis muscle during rest lip posture, lip position at maximum biting, lip position at maximum sealing effort, lip position at chewing, swallowing and phonation with the Medelec MS-25 electromyographic machine. Lateral cephalometric radiographs was taken with the mandible in intercuspal position on all subjects. All data were recorded and statistically processed. The findings of this study can be summerized as follows: 1. In normal occlusion, the maximal mean amplitude of upper lip during the lip position at chewing was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 2. In Class III malocclusion, the maximal mean amplitude of upper lip during the lip position at chewing, swallowing and phonation was lower than that of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not statistically different. 3. Compare to normal occlusion, the Class III malocclusion was showed low maximal mean amplitude of upper lip during rest lip posture and the lip position at swallowing of saliva, and showed great maximal mean amplitude of lower lip and meantalis muscle during the lip position at chewing and phonation. 4. In normal occlusion, the maximal mean amplitude of upper lip during various lip position was not correlated with the length and thickness of upper lip, but the maximal mean amplitude of lower lip during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip. 5. In Class III malocclusion, the maximal mean amplitude of upper lip during rest lip posture was negatively correlated with the thickness of upper lip, and the maximal mean amplitude of lower lip and mentalis muscle during the lip position at chewing and swallowing was positively correlated with the thickness of lower lip and mentalis muscle. But the maximal mean amplitude of orbicularis oris and mentalis muscle during the other lip position was not correlated with the cephalometric measurements of soft tissue. 6. The correlation between the maximal mean amplitude of orbicularis oris and mentalis muscle and cephalometric measurements of incisors was not nearly present. 7. In normal occlusion, the maximal mean amplitude of lower lip and mentalis muscle during the lip position at maximum biting was negatively correlated with the angle between palatal plane and mandibular plane. In Class III malocclusion, the maximal mean amplitude of upper lip, lower lip and mentalis muscle during function was negatively correlated with the length of maxilla, the maximal mean amplitude of upper lip and lower lip during function was negatively correlated with the SNA and SNPo, and the maximal mean amplitude of lower lip during the lip position at chewing was negatively correlated with the ANB.

  • PDF

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

Combined Effects of Gamma-irradiation and Hyperthermia on the Human Cell Lines for Various Temperatures and Time Sequences (감마선과 온열치료 병용시 세포 치사 능력 증강에 관한 실험적 연구)

  • Koh Kyung Hwan;Cho Chul Koo;Park Woo Yoon;Yoo Seong Yul;Yun Hyong Geun;Shim Jae Won;Lee Mi Jung
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • We tried to establish the theoretical basis of clinical use of combined modality of hyperthermia and radiation therapy. For this purpose, we made an in vitro experiment in order to get the synergistic and/or additive effects on the cell killing of hyperthermia combined with radiation therapy by using the microwave-hyperthermia machine already installed at our department. In our experiment, we use two human cell lines: MKN-45 (adenocarcinoma of stomach) and K-562 (leukemia cell lines). In cases of combined treatments of hyperthermia and gamma-irradiation, the therapeutic effect was the highest in the simultaneous trial. Hyperthermia after gamma irradiation showed slightly higher therapeutic effect than that before irradiation without significant difference, but its effect was the same in the interval of 6 hours between hyperthermia and irradiation. The higher temperature and the longer treatment time were applied, the higher therapeutic effects were observed. We could observe the thermoresistance by time elapse at $43^{\circ}C$. When hyperthermia was done for 30 minutes at the same temperature, thermal enhancement ratio (TER) at DO. 01 (dose required surviving fraction of 0.01) were $2.5{\pm}0.08,\;3.75{\pm}0.18$, and $5.0{\pm}0.15\;at\;436{\circ}C,\;44^{\circ}C,\;and\;45^{\circ}C$ respectively in K-562 leukemia cell lines. Our experimental data showed that more cell killing effect can be obtained in the leukemia cell lines, although they usually are known to be radiosensitive, when treated with combined hyperthermia and radiation therapy. Furthermore, our data show that leukemia cell lines may have various intrinsic radiosensitivity, especially in vitro experiments. The magnitude of cell killing effect, however, will be less than that of MKN-45.

  • PDF

An experimental study of the strength and internal structure of solder joint of fixed partial denture (가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sang-Nam;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구)

  • Lee, Hyeon-Heon;Jang, Chul-Ho;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.62-72
    • /
    • 2007
  • The purpose of present study was to determine whether different kinds of curing lights can alter microtensile bond strength(MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Thirty clean mandibular 2nd primary molar's occlusal enamel were removed and class I cavity, size of $2{\times}4{\times}2mm$ was prepared. Dentin bonding agent was applied according to manufacturer's manual. Each group was cured with Halogen Curing Unit, Plasma Curing Unit and LED Curing Unit. Composite resin was bulk filled and photo cured with same curing unit. MTBS specimens which size is $0.7{\times}0.7{\times}4mm$ were prepared with low speed saw. Specimens were coded by their curing lights and wall positions (Halogen - Axial wall group, Halogen - Pulpal wall group, Plasma - Axial wall group, Plasma - Pulpal wall group, LED - Axial wall group, LED - Pulpal walt group). MTBS were tested at 1 mm/min cross Head speed by Universal Testing Machine. Fractured surface and bonding surface was observed with SEM. T-test between axial and pulpal specimens in each curing lights, one-way ANOVA among different curing light specimens in each wall positions were done. Weibull distribution analysis was done. The results were as follows : Mean MTBS of pulpal wall specimens were significantly greater than that of axial wall specimens at each curing units(p<.05). There was no significant difference in the MTBS among three curing units at axial wall and pulpal wall. In Weibull distribution, pulpal wall specimens were more homogeneous than axial wall specimens.

  • PDF

An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration (도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향)

  • Kang, Hae-Jin;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • The purpose of this study was to determine whether there were differences in shear bond strength to human dentin using IDS technique compared with DDS. Forty freshly extracted human molars were and devided into 4 groups. The control group specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent and cemented with resin cement. The IDS/SE(immediate dentin sealing, Clearfil$^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, Adapter$^{TM}$ Single Bond 2) specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent(Clearfil$^{TM}$ SE Bond and Adapter$^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. IDS/SE, IDS/SB and DDS specimens were thermocycled. Following that delay, specimens were cemented with resin cement. The dentin bonding agent was left unpolymerized until the application of porcelain restoration. Shear bond strengths were measured using a universal testing machine. Specimens also were evaluated for mode of fracture using an optical microscope. The mean shear bond strengths of control group and IDS/SE groups were not statistically different from one another. The bond strength of IDS/SE group had a significantly higher mean than that of DDS group. There was no significant difference in the mean shear bond strength between IDS/SB(4.11MPa) and DDS group. The evaluation of failure modes indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS group were interfacial. When preparing teeth for indirect ceramic restoration, IDS with Clearfil$^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Effects of ultrasonic thawing on the physicochemical properties of frozen pork (주파수에 따른 초음파 해동처리가 냉동 돈육의 이화학적 특성에 미치는 효과)

  • Kim, Jinse;Park, Seok Ho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Jo, Byeong-Gwan;Park, Jong Woo
    • Food Science and Preservation
    • /
    • v.24 no.2
    • /
    • pp.230-236
    • /
    • 2017
  • This study was carried out to investigate the effects of ultrasonic thawing on physicochemical characteristics of frozen pork sirloin. To determine the velocity of an ultrasonic thawing machine, $-80^{\circ}C$ frozen pork sirloins were thawed using 132, 580, and 1,000 kHz ultrasonic thawing machines, and the physicochemical properties of pork sirloin thawed with $15^{\circ}C$ tap water and those using the ultrasonic thawing machines were compared. As a result, thawing speed by ultrasonic thawing was three times faster than that of tap water, but drip weight loss rate is increased by about 5% during ultrasonic thawing compared to that during thawing in tap water. However, biochemical properties, such as pH, volatile basic nitrogen, thiobarbituric acid, and total aerobic bacteria, were not improved by ultrasonic thawing. Hunter values, such as total color change and redness, improved slightly after 580 kHz ultrasonic thawing. The hardness and chewiness of the pork sirloin decreased significantly after 580 kHz ultrasonic thawing; however, springiness was not changed. These results indicate that ultrasonic thawing is faster than thawing in tap water, but the physicochemical characteristics of frozen pork sirloin was not significantly improve by ultrasonic sound.