Numerical modeling and global performance analysis of a 15-MW Semisubmersible Floating Offshore Wind Turbine (FOWT)

  • Da Li;Ikjae Lee;Cong Yi;Wei Gao;Chunhui Song;Shenglei Fu;Moohyun Kim;Alex Ran;Tuanjie Liu
    • Ocean Systems Engineering
    • /
    • v.13 no.3
    • /
    • pp.287-312
    • /
    • 2023
  • The global performance of a 15 MW floating offshore wind turbine, a newly designed semisubmersible floating foundation with multiple heave plates by CNOOC, is investigated with two independent turbine-floater-mooring coupled dynamic analysis programs CHARM3D-FAST and OrcaFlex. The semisubmersible platform hosts IEA 15 MW reference wind turbine modulated for VolturnUS-S and hybrid type (chain-wire-chain with clumps) 3×2 mooring lines targeting the water depth of 100 m. The numerical free-decay simulation results are compared with physical experiments with 1:64 scaled model in 3D wave basin, from which appropriate drag coefficients for heave plates were estimated. The tuned numerical simulation tools were then used for the feasibility and global performance analysis of the FOWT considering the 50-yr-storm condition and maximum operational condition. The effect of tower flexibility was investigated by comparing tower-base fore-aft bending moment and nacelle translational accelerations. It is found that the tower-base bending moment and nacelle accelerations can be appreciably increased due to the tower flexibility.

A Routing Protocol of Optimal Medium per Hop based on a Max-Win Method (OMH-MW) for Overlapped Maritime Data Networks with Multiple Media (다중무선매체로 중첩된 해상데이터망을 위한 최다승기반 홉 단위 최적매체 경로배정 프로토콜)

  • Son, Joo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.667-674
    • /
    • 2011
  • Data networks at sea will be overlapped networks with not only traditional carriers such as RF, satellites but also BWA like wireless LAN, WiBro, and WCDMA in near future. In this paper, an overlapped MANET model for data networks at sea, and a routing protocol (OMH-MW) selecting optimal transmission medium for each hop in routes are proposed. OMH-MW measures the optimality of each medium regarding the transmission characteristics of each application and those of the medium in together. The most suitable medium to each link is selected as the link in routes. Performances are compared with those of the MWR (Max-Win based Routing protocol searching optimal routes with only one medium).

Structural Model Test for Strength Performance Evaluation of Fairlead Chain Stopper Installed on MW Class Floating Type Offshore Wind Turbine (메가와트급 부유식 해상풍력발전기용 페어리드 체인 스토퍼의 강도 성능평가를 위한 구조 모형 시험)

  • Chang-Yong Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.421-431
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing due to the influence of global warming. In a situation where the installation of floating wind turbines is increasing around the world, concerns about the huge loss and collapse of floating offshore wind turbines due to strong typhoons are deepening. Regarding to the safe operation of the floating offshore wind turbine, the development of a new type of disconnectable mooring system is required. A new fairlead chain stopper considered in this study is devised to more easily attach or detach the floating offshore wind turbine with mooring lines comparing to other disconnectable mooring apparatuses. In order to investigate the structural safety of the initial design of fairlead chain stopper that can be applied to MW-class floating type offshore wind turbine, scale-down structural models were produced using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by performing the tensile tests. The finite element analysis of fairlead chain stopper was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the finite element analysis, the structural weak parts on the fairlead chain stopper were reviewed. The structural model tests were performed considering the main load conditions of fairlead chain stopper, and the test results were compared to the finite element analysis. Through the results of this study, it was possible to experimentally verify the structural safety of the initial design of fairlead chain stopper. It is also judged that the study results can be usefully used to improve the structural strength of fairlead chain stopper in a detailed design stage.

Estimation of Annual Energy Production Based on Regression Measure-Correlative-Predict at Handong, the Northeastern Jeju Island (제주도 북동부 한동지역의 MCP 회귀모델식을 적용한 AEP계산에 대한 연구)

  • Ko, Jung-Woo;Moon, Seo-Jeong;Lee, Byung-Gul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.545-550
    • /
    • 2012
  • Wind resource assessment is necessary when designing wind farm. To get the assessment, we must use a long term(20 years) observed wind data but it is so hard. so that we usually measured more than a year on the planned site. From the wind data, we can calculate wind energy related with the wind farm site. However, it calculate wind energy to collect the long term data from Met-mast(Meteorology Mast) station on the site since the Met-mast is unstable from strong wind such as Typhoon or storm surge which is Non-periodic. To solve the lack of the long term data of the site, we usually derive new data from the long term observed data of AWS(Automatic Weather Station) around the wind farm area using mathematical interpolation method. The interpolation method is called MCP(Measure-Correlative-Predict). In this study, based on the MCP Regression Model proposed by us, we estimated the wind energy at Handong site using AEP(Annual Energy Production) from Gujwa AWS data in Jeju. The calculated wind energy at Handong was shown a good agreement between the predicted and the measured results based on the linear regression MCP. Short term AEP was about 7,475MW/year. Long term AEP was about 7,205MW/year. it showed an 3.6% of annual prediction different. It represents difference of 271MW in annual energy production. In comparison with 20years, it shows difference of 5,420MW, and this is about 9 months of energy production. From the results, we found that the proposed linear regression MCP method was very reasonable to estimate the wind resource of wind farm.

Multi-Body Dynamic Response Analysis of a MW-Class Wind Turbine System Considering Rotating and Flexibility (로터 회전 및 타워의 탄성력을 고려한 MW 급 풍력발전기의 비선형 다물체 동적 응답 해석)

  • Kim, Dong-Man;Kim, Dong-Hyun;Kim, Yo-Han;Kim, Su-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.78-83
    • /
    • 2009
  • In this study, computer applied engineering (CAE) techniques are fully used to conduct structural and dynamic analyses of a whole huge wind turbine system including composite blades, tower and nacelle. For this study, computational fluid dynamics (CFD) is used to predict aerodynamic loads of the rotating wind-turbine blade model. Multi-body dynamic structural analyses are conducted based on the non-linear finite element method (FEM) by using super-element method for composite laminates blade. Three-dimensional finite element model of a wind turbine system is constructed including power train(main shaft, gear box, coupling, generator), bedplate and tower. The results for multi-body dynamic simulations on the wind turbine's critical operating conditions are presented in detail.

  • PDF

Study on the Method of Analyzing Effective Demand for Housing Using RIR

  • Youngwoo KIM;SunJu KIM
    • The Journal of Economics, Marketing and Management
    • /
    • v.12 no.3
    • /
    • pp.23-33
    • /
    • 2024
  • This study aims to enhance the accuracy of effective demand analysis for publicly supported private rental housing by integrating the RIR into the traditional Mankiw-Weil (MW) model. Traditional models like the M-W model, which account for household income, housing costs, and household size, often fall short in estimating demand driven by large-scale development projects. By integrating the RIR factor, this study introduces a more accurate and practical approach to analyzing effective housing demand. Findings show that the modified M-W model incorporating RIR predicts effective demand with greater precision than traditional methods. This advancement allows developers to plan projects more efficiently and aids governments and local authorities in implementing more effective housing policies. Furthermore, the study assesses the real housing cost burden on households, elucidating their capacity to pay housing costs based on household size and income quintile. This information enables policymakers to design targeted housing support policies for specific demographic groups. Additionally, the research provides comprehensive policy recommendations tailored to various regions and housing types. Overall, this study lays a vital groundwork for the long-term analysis of the effects of economic changes and housing market trends on effective demand.

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • Kim, Un-Hyeong
    • Fire Protection Technology
    • /
    • s.24
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

Simulation Model Development of Korean LVRT capability for evaluating the WTG-interconnected Power Systems Performance (풍력발전연계 전력계통의 성능평가를 위한 국내 풍력발전기 LVRT 전사모델 개발)

  • Han, Jun-Bum;Son, Hyeok-Jin;Kook, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1814-1821
    • /
    • 2012
  • As a new Korean grid code which includes LVRT requirement to wind farm of which capacity is greater than 20MW is activated in 2012, this paper developed the analytical model of the Korean LVRT for the simulation based feasibility study of the wind farm interconnection into power systems. The developed model of the LVRT is verified by applying it into the performance evaluation of the wind farm interconnected power systems and the effect of Korean LVRT is analyzed through case studies considering typical disturbances of power systems.

A Study on the Model Experiment for Smoke Flow in Road Tunnel Fire (도로터널 화재발생시 연기유동에 관한 축소모형실험 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kang, Se-Gu;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • In this study, smoke movement in tunnel fire with natural and longitudinal ventilation systems has been investigated. Reduced-scale experiments were carried out under the Froude scaling using 14.55kW fire source with a wick and experimental data is obtained with 1/18 model tunnel test. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gas was measured at emergency exit point. The results show that refuge time for 225m intervals of emergency exit in case of natural ventilation systems is 256 seconds and critical velocity for sufficient back-layer prevention is 2.8m/s for fire strength of 20MW.

  • PDF

A Study on Components Load of 5MW Wind Turbine Pitch Drive (5MW 풍력용 Pitch Drive 구성품의 부하에 관한 연구)

  • Kim, Dong-Young;Lee, In-Bum;Liang, Long-Jun;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.115-120
    • /
    • 2014
  • Wind power is a type of clean energy source which does not produce carbon dioxide. The wind turbine industry is considered as a major growth industry in many countries. The main cause of wind turbine failure arises in the wind turbine gearbox, and the main type of damage occurs in the bearings and gears. Therefore, predictions of gear and bearing damage are very important to ensure the reliability of the wind turbine reducers used in these systems. In this research, in order to optimize the wind turbine reducer, a series of simulations and redesigns was done using the tool RomaxDesigner. The RomaxDesigner model was used to analyze the bearing life of the duty cycle for a 5 MW wind-turbine pitch drive and to calculate the load in operating states. The reducer was designed to satisfy the life requirement by analyzing bearing damage and calculating the stress values of the main parts of the reducer.