• Title/Summary/Keyword: MUTARS$^{(R)}$ distal femur tumor endoprostheses

Search Result 2, Processing Time 0.014 seconds

The Failure of Polyethylene Lock of MUTARS Distal Femur Tumor Endoprostheses: A Case Report (원위 대퇴골 종양 금속 대치물(MUTARS$^{(R)}$)의 폴리에틸렌 잠김(LOCK)부 파손: 증례 보고)

  • Jeong, Won-Ju;Park, Il-Hyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.19 no.2
    • /
    • pp.74-77
    • /
    • 2013
  • The guidelines for the treatment of massive bone defects caused by bone resection due to tumors have changed from amputation to limb salvaging surgery. Limb salvaging surgery using endoprotheses is a well-established procedure. However, Aseptic loosening, infection, and mechanical defect remain significant problems. Among them, we experienced the case with a breakage of polyethylene lock of MUTARS$^{(R)}$ distal femur tumor Endoprostheses.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.