• Title/Summary/Keyword: MS-10

Search Result 7,048, Processing Time 0.038 seconds

A Study on the Identification of Target Compounds From the GC/MS Data (GC/MS분석자료의 목표물질 인식에 관한 연구)

  • 민홍기;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.223-228
    • /
    • 1989
  • In this paper, the computerized interpretation of the analytical chemical data, especially GC/MS data, was performed for the purpose of prescreening of the target compounds. First, the data from the analytical instrument was analyzed to get the information about the retention time of the ISTD and the time inteval between the records. Second, the identification of the characteristic ion peaks was performed by calculating the ratio of the heights and the relative slope sensitivity of the characteristic mass abundance.

  • PDF

Analysis of Photodegradation Products of Organic Photochromes by LC/MS

  • Lim, Young-Hee;Youn, Yeu Young;Kim, Kyung Hoon;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.101-103
    • /
    • 2012
  • The ultraviolet (UV) degradation products of photochromic naphthoxazine and naphthopyran derivatives in acetonitrile were separated and identified using liquid chromatography-mass spectrometry (LC-MS). Photodegradation resulted in oxidation of products.

𝛽-FUZZY FILTERS IN MS-ALGEBRAS

  • Alaba, Berhanu Assaye;Alemayehu, Teferi Getachew
    • Korean Journal of Mathematics
    • /
    • v.27 no.3
    • /
    • pp.595-612
    • /
    • 2019
  • In this paper, we introduce the concept of ${\beta}$-fuzzy filters in MS-algebras and ${\beta}$-fuzzy filters are characterized in terms of boosters. It is proved that the lattice of ${\beta}$-fuzzy filters is isomorphic to the fuzzy ideal lattice of boosters.

Low Power 10-Bit 10MS/s ADC for Mobile Communication System (무선통신용 저전력 10-Bit 10MS/s ADC)

  • Kim Jun-Ho;Lee Youg-Jic;Kim Joon-Yub
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.27-30
    • /
    • 2002
  • 10-bit 해상도, 10MS/s의 ADC를 Stage 당 1.5-Bit의 Resolution을 가지는 Redundant signed digit(RSD) 방식의 파이프라인 구조를 이용하여 설계하였다. Error Correction Logic을 사용함으로써 비교기를 Coarse하게 설계하였고 잔류 전압 증폭기의 최적 Scaling을 통하여 일반적인 ADC에 비해 성능 저하 없이 효율적으로 소비 전력을 감소시켰다. 또한, Charge Pump의 선택적 사용을 통해 기생 커패시턴스의 영향을 최소화함으로써 잔류전압 증폭기의 출력 전압 특성을 향상 시켰다. 삼성 0.35u CMOS 공정 파라미터를 이용하여 입력 전압 $-1{\sim}1V$, 공급 전압 $-1.5{\sim}1.5V$에서 18.73mW로 설계하였으며 HSPICE로 시뮬레이션 하였다.

  • PDF

A 8-bit 10-MHz CMOS A/D Converter (8-bit 10-MHz CMOS A/D 변환기)

  • 박창선;손주호;이준호;김종민;김동용
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.263-266
    • /
    • 1999
  • In this work, a A/D converter is implemented to obtain 8bit resolution at a conversion rate of 10MS/s for video applications. This architecture is proposed using the Pipelined architecture for high speed conversion rate and the Successive - Approximation architecture for low power consumption, and consists of two identical stages that consist of sample/hold circuit, low power comparator, voltage reference circuit and MDAC of binary weighted capacitor array. Proposed A/D converter is designed using 0.25${\mu}{\textrm}{m}$ CMOS technology The SNR is 80㏈ at a sampling rate of 10MHz with 1.95MHz sine input signal. When an 8bit 10MS/s A/D converter is simulated, the Differential Nonlinearity / Integral Nonlinearity (DNL/ INL) error are $\pm$0.5 / $\pm$2 LSB, respectively. The power consumption is 13㎽ at 10MS/s.

  • PDF

A 12b 10MS/s CMOS Pipelined ADC Using a Reference Scaling Technique (기준 전압 스케일링을 이용한 12비트 10MS/s CMOS 파이프라인 ADC)

  • Ahn, Gil-Cho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.11
    • /
    • pp.16-23
    • /
    • 2009
  • A 12b 10MS/s pipelined ADC with low DC gain amplifiers is presented. The pipelined ADC using a reference scaling technique is proposed to compensate the gain error in MDACs due to a low DC gain amplifier. To minimize the performance degradation of the ADC due to amplifier offset, the proposed offset trimming circuit is employed m the first-stage MDAC amplifier. Additional reset switches are used in all MDACs to reduce the memory effect caused by the low DC gain amplifier. The measured differential and integral non-linearities of the prototype ADC with 45dB DC gain amplifiers are less than 0.7LSB and 3.1LSB, respectively. The prototype ADC is fabricated in a $0.35{\mu}m$ CMOS process and achieves 62dB SNDR and 72dB SFDR with 2.4V supply and 10MHz sampling frequency while consuming 19mW power.

Improved Preimplantation Development of Cloned Porcine Embryos through Supplementation of Histone Deacetylase Inhibitor MS-275

  • Fang, Xun;Qamar, Ahmad Yar;Shin, Sang Tae;Cho, Jongki
    • Journal of Veterinary Clinics
    • /
    • v.36 no.5
    • /
    • pp.253-258
    • /
    • 2019
  • The objective of this study was to analyse the effects of MS-275 (Class I and II histone deacetylase inhibitor) supplementation on the development of porcine in-vitro somatic nuclear transfer embryo production. During in-vitro development, early embryos were exposed to different concentrations of MS-275 (0, $5{\mu}M$, $10{\mu}M$, and $20{\mu}M$). In in-vitro culture supplemented group, the blastocyst development rate was significantly enhanced by $10{\mu}M$ concentration than other groups (24.0% vs. 19.3%, 21.8%, 11.5%; P < 0.05). Additionally, the 6 h supplementation group, significantly improved the blastocysts production than 24 h, 48 h and control groups (26.1% vs. 17.0%, 15.2%, 2.8%; P < 0.05). Following supplementation with optimal concentrations and time ($10{\mu}M$-6 h group), the blastocyst production was significantly higher than control (25.7% vs 15.8%; P < 0.05). The optimal concentrations of MS-275 significantly enhanced the percentages of ICM:TE than control (43.6% vs. 38.4%; P < 0.05) accompanied with significantly higher expression levels of reprogramming related genes (POU5F1, Naong, and SOX2). In conclusion, the optimal concentrations of $10{\mu}M$ MS-275 and 6 h supplementation during in-vitro culture can significantly improve the quality of porcine in-vitro somatic nuclear transfer embryos through histone acetylation and epigenetic modification. Increasing the efficiency of clonal animal production will greatly promote the development of animal disease models and xenotransplantation.

Solvent-free determination of BTEX in water using repetitive membrane extraction followed by GC-MS (반복적인 막 추출과 GC-MS를 이용한 물 중 BTEX의 분석)

  • Kim, He-Kap;Kim, Se-Young;Lee, Soo-Hyung
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.352-359
    • /
    • 2011
  • An analytical method for solvent-free determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using repetitive membrane extractions coupled to cryofocusing and GC-MS was derived. BTEX compounds that permeated through a nonporous silicone membrane from the aqueous phase and evaporated into the acceptor phase were purged into a cryofocusing trap ($-100^{\circ}C$) with helium gas. The BTEX compounds, thus enriched in the trap, were thermally desorbed into a capillary column GC and detected using an MS. The flow rate of the donor phase (30 mL water) was set at 10 mL/min, and membrane extractions, accomplished by returning the water drained from the extraction module to the sample container, were repeated three times at $20{\pm}2^{\circ}C$. Although recoveries (%) were variable, from the highest for benzene (approximately 80%) to the lowest for ethylbenzene and xylenes (3.5-10%), the method showed satisfactory precision (RSD 2.2-10%) with good-linearity calibration curves ($r^2$ 0.9976-0.9997 in 1-100 ${\mu}g$/L range) for all of the compounds. The method detection limits (MDLs) ranged from 0.16 to 1.8 ${\mu}g$/L. The results showed the method's advantages such as short analysis time and overall simplicity without solvent compared to the conventional techniques.

HPLC-MS/MS Detection and Sonodegradation of Bisphenol A in Water (HPLC-MS/MS를 이용한 Bisphenol A 분석 및 초음파에 의한 분해 특성 조사)

  • Park, Jong-Sung;Yoon, Yeo-Min;Her, Nam-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.639-648
    • /
    • 2010
  • The optimal conditions for the analysis of BPA by HPLC-MS/MS was investigated and the ultrasound degradation capacity of the BPA, with the goal to establish the proper directions for analyzing infinitesimal quantities of BPA by HPLC-MS/MS was examined. The MDL and LOQ of BPA analyzed by HPLC-MS/MS were measured 0.13 nM and 1.3 nM respectively, its sensitivity about 620 and 32 times greater than HPLC-UV (MDL: 81.1 nM, LOQ: 811 nM) and FLD (MDL: 4.6 nM, LOQ: 46 nM). In other words, the new method enables the analysis of BPA with the accuracy up to one 1,180th of the amount specified in U.S. EPA guideline for drinking water. Degradation rate of BPA by ultrasound measured over 95% under 580 kHz and 1000 kHz frequency within 30 minutes of treatment, whereas the rate showed some decrease at 28 kHz frequency. At 580 kHz of ultrasound has proven to be the most effective among others at degradation rate and $k_1$ value, so we concluded that this frequency of ultrasound creates hospitable condition for the combined process of degradation by pyrolysis and oxidization. With the addition of 0.01 mM of $CCl_4$, BPA with the initial concentration of 1 ${\mu}M$ was degraded by more than 98% within 30 minutes, the $k_1$ value measured 5 minutes and 30 minutes into the experiment both showed increases by 1.4 and 1.1 times, respectively, compared with BPA without $CCl_4$. It is also found that the main degradation mechanism of BPA by ultrasound is oxidization process by OH radical, based on the fact that the addition of 10 mM of t-BuOH decreased the rate of BPA degradation by around 60%. However, 33% of BPA degradation rate obtained with the addition of t-BuOH implies further degradation done by pyrolysis or other sorts of radical beside OH radical.

Effects of RF Pulsing on the Ionization Enhancement in Ionized Magnetron Sputtering (RF pulsing이 Ionized Magnetron Sputtering의 이온화율 향상에 미치는 효과)

    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.255-260
    • /
    • 1998
  • The ionized magnetron sputtering is very useful in filling of small metal contact or via in ULSI processing with very high ionization upto 80% based on incoming flux ratio. But fairly high sputtering gas pressure is required to get high ionization, which instead gives low deposition rate and diverse incoming neutral's angular distribution. The electron quenching by heavily sputtered metals and gas rarefaction were considered the main causes of decreased ionization in this process. RF pulsing of sputtering power was proposed to solve those two problems. The results showed that 10㎳/10 ㎳ and 100㎳/100 ㎳ of on/off pulsings were optimal pulse conditions from OES measurements and also XRD of deposited Ag film showed distinct change of (111) to (200) preferred orientation. These results were analysed in a view point of neutral gas heating and cooling by high power sputtering.

  • PDF