• 제목/요약/키워드: MRS

검색결과 633건 처리시간 0.024초

Combination of Magnetic Resonance Spectroscopy and 11C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma

  • Nijiati Kudulaiti;Tianming Qiu;Junfeng Lu;Huiwei Zhang;Zhengwei Zhang;Yihui Guan;Dongxiao Zhuang;Jinsong Wu
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.967-975
    • /
    • 2019
  • Objective: To evaluate whether the combination of magnetic resonance spectroscopy (MRS) and 11C-methionine positron emission tomography (11C-MET PET) could increase accurate diagnostic sensitivity for non-enhancing supratentorial gliomas. Materials and Methods: Between February 2012 and December 2017, 109 patients with non-enhanced supratentorial lesions on contrast-enhanced MRI were enrolled. Each patient underwent MRS and 11C-MET PET before treatment. A lesion was considered to be a glioma when either the MRS or 11C-MET PET results reached the diagnostic threshold. The radiological diagnosis was compared with the pathological diagnosis or medical diagnostic criteria. Results: The sensitivity and specificity were 60.0% and 50.0% for MRS and 75.8% and 50.0% for 11C-MET PET, respectively. Upon combining the two modalities, the sensitivity and specificity of the imaging-based diagnosis prior to surgery reached 89.5% and 42.9%, respectively. Statistically significant differences in the sensitivities were observed between the combined and individual approaches (MRS alone, 89.5% vs. 60.0%, p < 0.001; 11C-MET PET alone, 89.5% vs. 75.8%, p = 0.001). However, no significant differences in specificity were observed between the combined and individual modalities. Conclusion: The combination of MRS and 11C-MET PET findings significantly increases accurate diagnostic sensitivity for non-enhancing supratentorial gliomas without significantly lowering the specificity. This finding suggests the potential of the combined MRS and 11C-MET PET approach in clinical applications.

이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구 (The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique)

  • 염헌규;이종민;김용선;이상권;서경진;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 목적 : 인체의 심근 및 간조직의 생체내 $^{31}P$ MRS에서 NOE 효과에 의한 분광신호 세기의 증가를 평가하고자 하였으며 또한 동일 장기에서 대사물질에 따른 NOE 효과의 차이를 알아보고자 하였다. 대상 및 방법: 열명의 정상 성인군(남:여=8:2, 연령분포=24-32)을 대상으로 1.5T 자기공명영상/분광 장치에서 $^1H-^{31}P$ 이중 튜닝 표면 코일을 사용하여 생체내 $^{31}P$ MRS를 시행하였다. $^{31}P$ MRS 측정은 이차원 화학변위영상기법을 사용하였으며 동일한 파라미터에서 NOE 효과 없이 그리고 $^1H$ decoupling상태에서 NOE 효과에 의한 $^{31}P$ MRS 데이터를 획득하였다. $^{31}P$ MRS raw data의 postprocessing 후 얻어진 스펙트럼에서 주요 대사물질들의 신호증가를 비교하였다. 결과: 간조직의 $^{31}P$ HRS에서 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%),\;PME\;(31\%)$였다. 간조직의 경우 크리아틴 키나제가 없기 때문에 PCr 신호는 관찰되지 않았다. 심근의 $^{31}P$ MRS은 whole body 코일이 표면 코일보다 우수한 scout 영상을 제공하여 $^{31}P$ MRS의 localization에 유리하였다. $^{31}P$ 심근 다중 체적 스펙트럼에서 , 혈액의 DPG 신호는 심근으로부터 멀어질 수록 증가하는 양상을 나타내었고 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;PDE\;(51\%),\;DPG\;(72\%)$ 였다. 결론: 간조직에 비해 심근의 경우 큰 신호증가를 보였고 이는 간조직 대사물질들의 $^{31}P$가 심근과는 다른 $^1H$ coupling을 나타냄을 의미한다고 해석할 수 있다.

  • PDF

Magnetic Resonance Findings in Two Episodes of Repeated Cerebral Fat Embolisms in a Patient with Autologous Fat Injection into the Face

  • Lee, Kyung-Mi;Kim, Eui-Jong;Jahng, Geon-Ho;Chang, Dae-Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.312-315
    • /
    • 2012
  • We report magnetic resonance image (MRI) and magnetic resonance spectroscopy (MRS) findings in a patient of cerebral fat embolism (CFE) occurred in a 26-year-old woman after an autologous fat injection into the face. After initial neurologic symptom onset, MRI and MRS data were obtained two times to investigate repeated CFE. We obtained the MRS data in the two different time intervals and two different echo times to compare the lesions with normal brain parenchyma. The results of MRS data showed that a decrease in N-acetyl-aspartate, an increase in lactate and a very high early peak of free lipids between 0.9 and 1.4 ppm were obtained at the acute infarcted lesion as compared with normal brain parenchyma. In addition, these findings were more clearly detected on short echo time spectrum rather than long spectrum. A close relationship between the clinical manifestations and MRI and MRS findings of the brain can helpful to distinguish CFE with other conditions and to evaluate the cause materials of infarctions rather than conventional MRI or diffusion-weighted imaging.

다중 로보트 시스템의 작업 스케쥴링 및 성능 평가 (Job scheduling and performance evaluation of MRS(Multi Robot System))

  • 이기동;조혜경;이범희;고명삼
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.423-428
    • /
    • 1990
  • A mixed IP formulation is presented which concurrently routes and sequences the tasks on the MRS, reflecting the flexible characteristics. As a preliminary work for the performance evaluation of the MRS, a two robot system working on independent tasks is studied. Models for three types of the system capable of simple error recovery function are established using queueing model, and performances are evaluated and analysed.

  • PDF

A multilingual grammar model of honorification: using the HPSG and MRS formalism

  • Song, Sanghoun
    • 한국언어정보학회지:언어와정보
    • /
    • 제20권1호
    • /
    • pp.25-49
    • /
    • 2016
  • Honorific forms express the speaker's social attitude to others and also indicate the social ranks and level of intimacy of the participants in the discourse. In a cross-linguistic perspective of grammar engineering, modelling honorification has been regarded as a key strategy for improving language processing applications. Using the HPSG and MRS formalism, this article provides a multilingual grammar model of honorification. The present study incorporates the honorific information into the Meaning Representation System (MRS) via Individual Constraints (ICONS), and then conducts an evaluation to see if the model contributes to semantics-based language processing.

  • PDF

False Positive SOD Activity of Bifidobacterium spp. Grown in MRS Medium

  • Chang, Woo-Suk;So, Jae-Seong
    • Journal of Microbiology and Biotechnology
    • /
    • 제8권4호
    • /
    • pp.305-309
    • /
    • 1998
  • The superoxide dismutase (SOD) activity of seven Bifidobacterium spp. strains was examined by an indirect SOD assay method. Some Bifidobacterium spp. showed significant levels of SOD activity. However, we could not observe any significant differences between anaerobic and aerobic cultures. Furthermore, although several Bifidobacterium spp. exhibited some degree of tolerance to paraquat which produces superoxide radicals, the apparent SOD activity of these strains was not correlated with their resistance to paraquat. In addition, when we added increasing amounts of manganese or iron to MRS medium which had been prepared without either of the metal ions, the apparent SOD activity of cell free extracts (CFEs) was increased with increasing concentration of both metal ions. To our surprise, the heat-denatured CFEs also showed nearly identical correlative patterns. Based on these results, the apparent SOD activity was likely due to a nonenzymatic dismutation. These results strongly suggest that high concentration of divalent metal ions ($Mn^{2+}$, $Fe^{2+}$) in MRS medium result in nonenzymatic dismutation which can lead to false positive SOD activities in Bifidobacerium spp.

  • PDF

멀티 라디오 애드혹 네트워크에서의 멀티 채널을 이용한 모델 기반 레이트 분할 알고리즘 (A Model-based Rate Separation Algorithm Using Multiple Channels in Multi-Radio Ad Hoc Networks)

  • 김석형;김동욱;서영주;권동희
    • 한국통신학회논문지
    • /
    • 제36권1A호
    • /
    • pp.73-81
    • /
    • 2011
  • IEEE 802.11 물리 (Physical) 계층과 MAC (Medium Access Control) 계층은 다수의 채널과 데이터 레이트를 제공한다. IEEE 802.11 멀티 라디오 애드혹 네트워크의 성능을 향상 시키기 위해서는 가용한 채널과 데이터 레이트를 효율적으로 할당해야 한다. 하지만 IEEE 802.11 멀티 레이트 네트워크에서는 낮은 레이트 링크가 높은 레이트 링크에 영향을 미쳐서 네트워크 성능을 심각히 저하시키는 문제인, RA (Rate Anomaly)가 발생한다. 따라서, 본 논문에서는 다른 데이터 레이트를 사용하는 링크들을 멀티 채널로 분할시킴으로써 이러한 RA문제를 완화하는 모델 기반 레이트 분할 (Model-based Rate Separation, MRS) 알고리즘을 제안한다. MRS 알고리즘은 IEEE 802.11 싱글 홉 (single-hop) 네트워크의 성능을 측정하는 기존의 성능 모델을 활용하여 낮은 레이트 링크와 높은 레이트 링크를 분산시킨다. 시뮬레이션을 통해 멀티 라디오 애드혹 네트워크에서 MRS 알고리즘이 기존 알고리즘들에 비해 향상된 네트워크 성능을 나타냄을 확인하였다.

한방병원에 내원하는 갱년기 여성의 체성분 특성과 Menopause Rating Scale(MRS), The Menopause-specific Quality of Life Questionnaire(MENQOL)을 통한 증상에 대한 상관도 분석 (A Study on the Relationship between Body Composition and Menopause Rating Scale (MRS), The Menopause-specific Quality of Life Questionnaire (MENQOL) of Postmenopausal Women)

  • 박강인;박연경;박경선;황덕상;이창훈;장준복;이진무
    • 대한한방부인과학회지
    • /
    • 제28권1호
    • /
    • pp.85-91
    • /
    • 2015
  • Objectives: Postmenopausal symptoms are subject to many factors. Recently, obesity has been suggested as a factor of hot flush. So this study aims to report the relationship between body composition and Menopause Rating Scale (MRS), The Menopause-specific Quality of Life Questionnaire (MENQOL) of postmenopausal women. Methods: We studied 42 climacteric women who had visited Kyung Hee University Hospital at Gangdong from April 2011 to July 2014. 42 women had filled out MRS, MENQOL, and they had taken body composition tests. Pearson correlation tests were conducted. (Correlation was statistically significant at the 0.05 level) Results: Correlation between psychological subscale of MENQOL and Waist-Hip Ratio (WHR) was statistically significant (pearson correlation coefficient=0.385; p-value=0.012). But other subscales of MRS and MENQOL were not statistically related with body composition. Conclusions: WHR could be an important factor of psychological health of menopausal women. So, abdominal fat reduction must be considered when curing menopausal symptoms. In connection with climacteric depression, well-designed studies would be necessary.

Fat Quantification in the Vertebral Body: Comparison of Modified Dixon Technique with Single-Voxel Magnetic Resonance Spectroscopy

  • Sang Hyup Lee;Hye Jin Yoo;Seung-Man Yu;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.126-133
    • /
    • 2019
  • Objective: To compare the lumbar vertebral bone marrow fat-signal fractions obtained from six-echo modified Dixon sequence (6-echo m-Dixon) with those from single-voxel magnetic resonance spectroscopy (MRS) in patients with low back pain. Materials and Methods: Vertebral bone marrow fat-signal fractions were quantified by 6-echo m-Dixon (repetition time [TR] = 7.2 ms, echo time (TE) = 1.21 ms, echo spacing = 1.1 ms, total imaging time = 50 seconds) and single-voxel MRS measurements in 25 targets (23 normal bone marrows, two focal lesions) from 24 patients. The point-resolved spectroscopy sequence was used for localized single-voxel MRS (TR = 3000 ms, TE = 35 ms, total scan time = 1 minute 42 seconds). A 2 × 2 × 1.5 cm3 voxel was placed within the normal L2 or L3 vertebral body, or other lesions including a compression fracture or metastasis. The bone marrow fat spectrum was characterized on the basis of the magnitude of measurable fat peaks and a priori knowledge of the chemical structure of triglycerides. The imaging-based fat-signal fraction results were then compared to the MRS-based results. Results: There was a strong correlation between m-Dixon and MRS-based fat-signal fractions (slope = 0.86, R2 = 0.88, p < 0.001). In Bland-Altman analysis, 92.0% (23/25) of the data points were within the limits of agreement. Bland-Altman plots revealed a slight but systematic error in the m-Dixon based fat-signal fraction, which showed a prevailing overestimation of small fat-signal fractions (< 20%) and underestimation of high fat-signal fractions (> 20%). Conclusion: Given its excellent agreement with single-voxel-MRS, 6-echo m-Dixon can be used for visual and quantitative evaluation of vertebral bone marrow fat in daily practice.