• 제목/요약/키워드: MRI scan brain image

검색결과 29건 처리시간 0.023초

MRI 외부병원 판독 수가 인상의 효과 분석: 뇌 관련 자기공명영상을 중심으로 (An Analysis on the Effect of the Increase in the Fee of Magnetic Resonance Imaging Deciphering of the External Hospital: Focusing on the Brain Magnetic Resonance Imaging)

  • 김록영;사공진;조민호;위세아;이진용;김용규
    • 보건행정학회지
    • /
    • 제31권3호
    • /
    • pp.261-271
    • /
    • 2021
  • Background: In 2018, the government increased the fee for the magnetic resonance imaging (MRI) image deciphering services of the external hospital to discourage the redundant MRI scan and to induce appropriate use of the MRI services. It is important to evaluate the effect of the policy to provide the basis for establishing other MRI-related policies. Methods: The healthcare data of the patients who had brain MRI scans were organized by episode and analyzed using the panel study in order to find out the effect of the MRI-related policy on the substitution effect and the medical expenses. Results: As a result of the increase in the fee of deciphering the MRI image, there has been an uplift in deciphering the MRI scan of the external hospital. It implies that more hospitals chose to use the MRI scan taken by other clinics or hospitals, rather than the MRI scan taken at their own facilities. Conclusion: The research results imply that a policy that facilitates the exchange of the medical image data between the hospitals is needed in order to establish an efficient management system of the healthcare resources. Such improvement is expected to reduce the social cost and contribute to the stability in the finance of national health insurance.

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권12호
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구 (Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study)

  • 김남영;김주희;임준;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.9-14
    • /
    • 2021
  • 방사선에 의한 피폭 없이 대조도가 우수한 영상의 획득이 가능한 자기공명영상은 진단에 필수적이지만 영상에서의 노이즈 발생은 불가피한 요소이기 때문에 이를 보완하기 위해 자기공명영상장치의 변수들을 조절하여 우수한 특성을 가진 영상을 획득할 수 있다. 이 중, 여기횟수 (NEX; number of excitation)는 추가적인 영상 특성의 저하 없이 우수한 특성의 영상을 획득할 수 있지만 scan time이 증가하여 motion artifact를 발생시킬 수 있고, scan time의 증가에 비례하여 영상의 특성이 향상되지 않기 때문에 적절한 NEX의 설정이 필요하다. 따라서, 본 연구에서는 MRiLab simulation program을 통해 자기공명영상의 모든 변수들을 고정시킨 후, NEX만을 조절하여 획득한 뇌 T2 강조 영상의 정량적 평가를 통해 NEX 변화에 따른 영상 특성의 경향성을 평가하고자 하였다. 획득한 영상의 노이즈 레벨 및 유사도 평가를 하기 위해 신호 대 잡음비 (SNR; signal to noise ratio), 대조도 대 잡음비 (CNR; contrast to noise ratio), 평균 제곱근 오차 (RMSE; root mean square error) 그리고 최대 신호 대 잡음비 (PSNR; peak signal to noise ratio)를 계산하였다. 결과적으로, 노이즈 레벨 및 유사도 평가 인자 모두 NEX가 증가함에 따라 개선된 값을 보였으나, 점차 증가폭이 감소함을 보였다. 따라서, 과도하게 큰 NEX는 장시간의 scan에 따른 motion artifact를 발생시켜 영상 특성을 저하시킬 수 있으므로, 적절한 NEX의 설정이 중요함을 확인하였다.

Arachnoid Granulations Mimicking Multiple Osteolytic Bone Lesions in the Occipital Bone

  • Park, Seong-Hyun;Park, Ki-Su;Hwang, Jeong-Hyun
    • Brain Tumor Research and Treatment
    • /
    • 제6권2호
    • /
    • pp.68-72
    • /
    • 2018
  • We report a rare case of arachnoid granulations mimicking multiple osteolytic bone lesions. A 66-year-old woman was admitted to a local clinic for a regular checkup. Upon admission, brain CT showed multiple osteolytic lesions in the occipital bone. These needed to be differentiated from multiple osteolytic bone tumor. Subsequent brain MRI revealed that the osteolytic lesions were isointense to cerebrospinal fluid, hyperintense on T2-weighted image, hypointense on T1-weighted image, and with subtle capsules around the osteolytic lesions that were visible after gadolinium injection. A bone scan revealed no radiotracer uptake. The lesions were in both the transverse sinuses and the torcular herophili. With typical radiological appearances of the lesions, the osteolytic lesions were diagnosed as multiple arachnoid granulations. No further treatment was planned. A 1-year follow-up brain CT scan revealed no change. We should consider the possibility of arachnoid granulations when multiple osteolytic lesions are observed in the occipital bone.

뇌심부자극술 시술환자의 뇌 자기공명영상에서 고주파 출력의 제한기준에 대한 임상적 유용성 평가 (Evaluation of Clinical Usefulness of Radio-Frequency Power Limitation in Brain MRI of Patients with Deep Brain Stimulation)

  • 연규진;장영애;이승근;이태수
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.139-144
    • /
    • 2017
  • To evaluation of clinical usefulness for B1+RMS limits, we compared image quality of Routine, Specific absorption rate (SAR) and Root mean square (RMS) protocol. 5 volunteers underwent Magnetic Resonance Imaging (MRI) scan of the brain using three different protocols. We draw Region of interest ROI in cortex, white matter, gray matter, putamen and thalamus of axial plan. Signal to noise ratio (SNR) were evaluated in each area and Contrast to noise ration (CNR) were evaluated between white matter and gray matter. Qualitative evaluation was used to score each ROI. B1+RMS is confirmed its usefulness compared to conventional SAR standard on the aspect of improvement of image quality, reduction of scan time and easy adjusting parameter.

3D 공간상에서의 주변 기울기 정보를 기반에 둔 필터 학습을 통한 MRI 영상 초해상화 (MRI Image Super Resolution through Filter Learning Based on Surrounding Gradient Information in 3D Space)

  • 박성수;김윤수;감진규
    • 한국멀티미디어학회논문지
    • /
    • 제24권2호
    • /
    • pp.178-185
    • /
    • 2021
  • Three-dimensional high-resolution magnetic resonance imaging (MRI) provides fine-level anatomical information for disease diagnosis. However, there is a limitation in obtaining high resolution due to the long scan time for wide spatial coverage. Therefore, in order to obtain a clear high-resolution(HR) image in a wide spatial coverage, a super-resolution technology that converts a low-resolution(LR) MRI image into a high-resolution is required. In this paper, we propose a super-resolution technique through filter learning based on information on the surrounding gradient information in 3D space from 3D MRI images. In the learning step, the gradient features of each voxel are computed through eigen-decomposition from 3D patch. Based on these features, we get the learned filters that minimize the difference of intensity between pairs of LR and HR images for similar features. In test step, the gradient feature of the patch is obtained for each voxel, and the filter is applied by selecting a filter corresponding to the feature closest to it. As a result of learning 100 T1 brain MRI images of HCP which is publicly opened, we showed that the performance improved by up to about 11% compared to the traditional interpolation method.

뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구 (A study on image registration and fusion of MRI and SPECT/PET)

  • 주라형;최용;권수일;허수진
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 1998
  • 방사성 의약품 또는 방사성 동위원소를 이용하여 동적 상태의 변화를 측정하고 핵자기 공명 영상에서 해부학적 기준 정보를 얻어 영상을 융합, 등록하고 같은 대상에서 비슷한 검사를 계속해서 비교하게 되며 해부학적 기준 정보나 다른 검사 기기 종류에서 반복되는 검사의 비교를 위해 영상 합성 연구가 유효하며 기능적 특성 때문에 단일 광자 방출 전산화 단층 촬영과 양전자 방출 단층 촬영은 해부학적 기준 정보가 필요하게 되고 같은 대상에서 이러한 해부학적 기준 정보를 얻고 기능적인 이상과 상관관계를 찾아내고 반복되는 진단에 대한 비교를 위해서 영상등록과 융합을 시행하였다. 해부학적 구조가 같은 특성을 갖는 여러 영상 시스템들을 이용하여 해부학적기준과 동적 정보를 함께 얻고 등록하기 위해 짝을 이루는 점올 이용하여 2 가지 영상 데이터에서 4 점 쌍 이상을 선택하여 등록하였다. 기준 영상과 짝을 이루는 점과 대응한 영상은 다른 색을 선택하여 영상을 구분하였으며 핵자기 공명영상을 기준영상으로 하고 단일 광자 방출 컴퓨터 단층 촬영 영상, 양전자 방출 전산화 단층 촬영 영상을 기준영상에 1:1 대응하여 영상을 등록하기 위해서 변환한다. 핵자기 공명 영상이 기준 영상으로 사용되지만 인터폴레이션 에러는 주어진 영상의 공간 주파수에 따라 달라지므로 낮은 해상도를 갖는 양전자 방출 전산화 단층 촬영 영상과 단일 광자 방출 컴퓨터 단층 촬영 영상의 인터폴레이션 에러는 적다. 따라서 방사성 동위원소를 이용하여 질병의 진단 및 질환의 병태 생리 생화학적 연구를 통한 신체의 동역학적 상태의 변화를 측정할 수 있는 이런 정량적이고 기능적인 정보를 해부학적 기준 정보를 주는 핵자기 공명 영상이나 컴퓨터 단층 촬영에서 반복 시행하여 검사와 진단에 용이하게 이용하고, 비교를 위해서 영상을 등록하고 융합하여 진단에 보다 좋은 결과를 얻을 수 있도록 하였다.

  • PDF

산소 호흡을 이용한 뇌의 관류 자기공명영상 (Perfusion RRI of the Brain Using Oxygen Inhalation)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.113-119
    • /
    • 2000
  • 목적 : 산소호흡을 이용한 뇌의 관류 자기공명영상의 임상적용 가능성을 알고자 하였다. 대상 및 방법 정상 성인 지원자 2명과 3명의 환자, 각각 모야모야병 환자 1명, 뇌경색환자 1명, 뇌수막종 환자 1명을 대상으로 하였으며, 1.5 Tesla의 자기공명영상 장치를 이용하여 뇌의 자화율 대조 (susceptibility contrast) echo planar image (EPI) 방법으로 뇌영역을 10 slice씩 25회(검사시간은 검사당 1.6초) 영상을 얻었다. 검사자는 안면마스크를 착용한 상태로 스캔 시작 8초 후부터 35초가지 산소 15 liter/min를 실내 공기와 혼합되어 흡입되도록 하였다. 획득된 영상을 Magnetom Vision (Siemens Medical Systems, Erlangen, Germany)의 VB31C 프로그램을 이용하여 산소투여전(3골 번째 검사)과, 산소투여 후의 초기 (12-18 번째 검사)와 후기(19-25 번째 검사) 군으로 나누었다. 초기 및 후기 군과 산소투여전 군의 신호차이는 Z-score 0.7 내지 1.0으로 하여 여러번 영상후 처리를 반복하여 difference map을 얻어서, T1 강조영상에 중첩시켜 관류 영상을 얻었다. 모야모야병 환자는 추가로 Gd-DTPA를 0.1 mmol/kg급속주사 후 동일한 방법으로 관류 영상을 얻어 산소호흡에 의한 관류 영상과 비교하였다. 결과 : 산소 공급 후에 시행한 자화율 대조 EPI 방법으로 2명의 지원자와 각각 1예의 모야모야병, 뇌경색, 뇌수막종 증례에서 혈류 분포를 반영하는 관류 영상을 얻을 수 있었다. 모야모야병 1예의 산소 호흡에 의한 관류 영상은 Gd-DTPA투여후의 관류 영상과 유사한 양상을 보였다. 결론 : 산소호흡을 이용한 자화율 대조 EPI 방법은 향후 뇌의 관류 자기공명영상 방법으로 적용이 가능하리라고 생각된다.

  • PDF

DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교 (Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2)

  • 최나래;남윤호;김동현
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.56-63
    • /
    • 2010
  • 목적 : 본 논문에서는 DIR 영상을 이용하여 두뇌의 피질두께측정 연구를 수행하는 한편 평행 영상기법 중 하나인 GRAPPA (generalized autocalibrating partially parallel acquisitions)를 이용하여 GRAPPA 인자 (reduction factor, R)가 2일 때와 평행 영상기법을 이용하지 않았을 때의 결과 비교를 통해 3D DIR 영상의 획득시간 단축 가능성을 제시하고자 한다. 대상 및 방법 : 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)의 3D DIR 펄스열을 이용하여 6명(남자 3명, 여자 3명, $25.33{\pm}2.25$살)의 정상인 뇌에 대한 3차원 영상을 얻었다. GRAPPA 시뮬레이션은 R=2 일 때를 가정하여 수행되었고 두뇌 피질두께측정을 위해 Analyze 9.0과 Freesurfer v.4.3.0 프로그램을 사용하였다. 결과로 얻은 데이터를 T-검증을 이용하여 비교분석 하였다. 결과 : GRAPPA 기법을 통하여 복원한 영상이 잡음이 증가하는 경향을 보였으나 두뇌 피질두께 측정에는 별다른 영향을 미치지 않았다. 통계분석을 통해 비교한 결과 대부분의 두뇌 영역에서 참조영상과 GRAPPA 기법을 이용한 영상의 차이가 유의하지 않았다. 결론 : 피질두께측정 연구에 있어서 3D DIR영상의 문제점 중 하나는 긴 영상획득시간이다. 따라서 평행영상 기법 중 하나인 GRAPPA 영상기법을 적용하면 피질두께측정 연구결과의 큰 차이없이 영상 획득 시간을 단축시킬 수 있다.