• 제목/요약/키워드: MRI diagnosis

Search Result 922, Processing Time 0.023 seconds

Multiparametric MRI in Active Surveillance of Prostate Cancer: An Overview and a Practical Approach

  • Chau Hung Lee;Teck Wei Tan;Cher Heng Tan
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1087-1099
    • /
    • 2021
  • MRI has become important for the detection of prostate cancer. MRI-guided biopsy is superior to conventional systematic biopsy in patients suspected with prostate cancer. MRI is also increasingly used for monitoring patients with low-risk prostate cancer during active surveillance. It improves patient selection for active surveillance at diagnosis, although its role during follow-up is unclear. We aim to review existing evidence and propose a practical approach for incorporating MRI into active surveillance protocols.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

Diagnostic Reliability & Case Reports Of The Dynamic MRI For Temporomandibular Joint Disease (악관절증의 진단을 위한 역동적 자기공명 영상의 이용 및 증례)

  • Park, Jin-Ho;Chin, Byung-Rho;Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.1
    • /
    • pp.141-148
    • /
    • 1995
  • The Magnetic resonance imaging has been used widely to evaluate the disk position without any interruption of the TMJ structures, and the dynamic MRI presenting computed serial imaging or the video-recorded simulation images is thought to be very effective to evaluate the disk position under function. This is to study the correlation between the clinical diagnosis and the findings of dynamic MRI for diagnosis of internal derangement of the 7 patients were examined clinically, and the movement of TMJ meniscus was reviewed in the dynamic MRI. MRI was very reliable to diagnose the amount of anterior displacement of articular disc, the structural abnormality of temporomandibular joint, the cause of functional limitation, and to differentiate the muscle related pain & dysfunction.

  • PDF

VALIDITY OF CLINICAL, TRANSCRANIAL RADIOGRAPHIC AND MAGNETIC RESONANCE IMAGING METHOD IN THE DIAGNOSIS OF INTERNAL DERANGEMENT OF TEMPOROMANDIBULAR JOINT (악관절장애 환자의 임상 및 측사위경두개 촬영에 의한 진단과 자기공명영상에 의한 진단의 비교연구)

  • Choi Jeong Hee;Chung Hyun Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.327-336
    • /
    • 1991
  • The purpose of this study was to evaluate the validity among the clinical, transcraial radiographic and MRI diagnosis in internal derangement of the temporomandibular joint. Fourty two temporomandibular joints were assessed in twenty one patients who visited the dental department of Chonnam National University Hospital with the complaint of temporomandibular disorder from Oct. 1990 to Oct. 1991. The results were as follows: 1. In the clinically symptomatic 29 TMJs, 26 (89.7%) joints reveal disc displacement and 3 (10.3%) joints reveal normal disc position on MRI. The sensitivity of clinical diagnosis was 0.77, and the specificity was 0.63. 2. In the normal 22 TMJs on the trans cranial radiographic finding, 16 (72.7%) joints reveal disc displacement, and 6 (27.3%) joints reveal normal disc position on MRI. In the abnormal 20 TMJs on the transcranial radiographic finding, 18 (90%) joints reveal disc displacement, and 2 (10%) joints reveal normal disc position on MRI. The sensitivity of trans cranial radio- graph was 0.53, and the specificity was 0.75.

  • PDF

A Study on the Diagnostic Usefulness of Ultrasound and Magnetic Resonance Imaging for the Diagnosis of Shoulder Rotator Cuff Tear (어깨 회전근개 파열 진단을 위한 초음파 검사와 자기공명영상 검사의 진단적 유용성 연구)

  • Chae-Won, Kang;Hyo-Young, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.961-968
    • /
    • 2022
  • Rotator cuff tears are a leading cause of shoulder pain in adults. Due to the increase in social activities, the number of patients complaining of shoulder pain is increasing, and interest in shoulder diseases is also increasing. With the development of ultrasound equipment, the sensitivity and specificity of diagnosis are high, and it is used to diagnose rotator cuff tears in musculoskeletal disease. Ultrasound is recognized as a complementary method to MRI examination in rotator cuff tears. Therefore, this study aimed to find out the diagnostic usefulness of ultrasound and MRI examinations in the diagnosis of shoulder rotator cuff tears.A retrospective analysis was performed on 262 patients who were diagnosed with final rotator cuff damage by arthroscopy after completing ultrasound and MRI examinations. Sensitivity, feature, positive predictive value, image predictive value, and touch were disassembled for the test results. In addition, the degree of clavicular tear was scored and recorded in 5 stages. Ultrasound examination was similar to MRI examination results for both full-thickness and partial tears, and there was no statistically significant difference. Partial tear test results showed higher positive predictive value and accuracy than MRI test. In conclusion, ultrasound can be fully utilized as a screening test for rotator cuff disease, and it is thought that it will be selected and used clinically according to the patient's constitution and situation.

MRI-guided Wire Localization Open Biopsy is Safe and Effective for Suspicious Cancer on Breast MRI

  • Wang, Hai-Yi;Zhao, Yu-Nian;Wu, Jian-Zhong;Wang, Zheng;Tang, Jing-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1715-1718
    • /
    • 2015
  • Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.

Role of Contrast-Enhanced Ultrasound as a Second-Line Diagnostic Modality in Noninvasive Diagnostic Algorithms for Hepatocellular Carcinoma

  • Hyo-Jin Kang;Jeong Min Lee;Jeong Hee Yoon;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.354-365
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations. Materials and Methods: We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar's test. Results: The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS. Conclusion: The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.

Clinical Application and Limitations of Myeloma Response Assessment and Diagnosis System (MY-RADS) (골수종 반응평가와 진단체계의 임상적용 및 제한점)

  • Dong Kyun Kim;Sung-Soo Park; Joon-Yong Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.51-74
    • /
    • 2023
  • Multiple myeloma, which is a proliferative disease of plasma cells that originate from a single clone, is the second most common hematologic malignancy following non-Hodgkin lymphoma. In the past, its diagnosis was made based on clinical findings (so-called "CRAB") and a skeletal survey using radiographs. However, since the implementation of the International Myeloma Working Group's revised guideline regarding the radiologic diagnosis of multiple myeloma, whole-body (WB) MRI has emerged to play a central role in the early diagnosis of multiple myeloma. Diffusion-weighted imaging and fat quantification using Dixon methods enable treatment response assessment by MRI. In keeping with the trend, a multi-institutional and multidisciplinary consensus for standardized image acquisition and reporting known as the Myeloma Response Assessment and Diagnostic System (MY-RADS) has recently been proposed. This review aims to describe the clinical application of WB-MRI based on MY-RADS in multiple myeloma, discuss its limitations, and suggest future directions for improvement.

A Study on the Optimal Information Provision for PET-MRI: Focused on Literature Article (PET-MRI에 대한 최적의 정보 제공에 대한 연구: 문헌 보고 중심으로)

  • DongSeob Son;EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.391-396
    • /
    • 2023
  • Currently, state-of-the-art devices such as SPECT, PET/CT, and PET/MRI are rapidly spreading nationwide, and the penetration rate of nuclear medical devices is also ranked fifth in the world. However, PET/MRI's system is slower and less common because it is more complex than PET/CT. The purpose of this study is to provide optimal information on PET/MRI according to the patient's disease. The subjects obtained information on head and neck cancer, pediatric patients, breast cancer patients, heart disease patients, lung cancer patients, and rectal cancer patients. We tried to accumulate protocols by obtaining a lot of information about each disease. In diagnosing head and neck cancer, it is believed that it is highly likely to be used in evaluating preoperative stage determination, recurrence and remote metastasis after treatment, and unclear primary cervical lymph node metastasis. Diagnosis and continuous follow-up of pediatric patients can increase patient benefits by minimizing radiation exposure. Breast cancer provides a comprehensive evaluation of the clinical need to determine the extent of disease in breast and local lymph nodes and the systematic stages of early diagnosis or recurrence. In diagnosing heart disease patients, MR-based PET motion correction helps to realize the full potential of PET images. For lung cancer patients, the clinical value and usefulness of the resolution and detection ability of integrated PET/MRI for soft tissues such as lung cancer will be sufficient. In diagnosing rectal cancer patients, the detection of missing residual diseases can change the clinical response evaluation for rectal cancer patients treated with TNT, and both the initial stage and treatment response evaluation are possible. Therefore, this literature study provided basic clinical data for PET/MRI tests.

Region Extraction & Disease Recognition in MRI (MRI 영상에서 영역추출과 질환인식)

  • Lee, Sang-Bock;Lee, Sam-Yol;Lee, Jun-Haeng
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.19-24
    • /
    • 2004
  • MRI imaging is one of the imaging techniques showing anatomical structures of human body for medical diagnosis, and has been researched in order to provide better quality of anatomical information. In this study, we propose a very useful method to extract an interest areas and how to diagnose necrolysis of femoral neck disease automatically. Regions of femoral neck is set using anatomical features and Hough transform and advantages of both region extension and histogram-based region segmentation method are combined for better region segmentation. As a result of the proposed method, good imaging quality was obtained for femoral neck with both normal and severe necrosis as well as for femoral neck in early stage of necrolysis.

  • PDF