• Title/Summary/Keyword: MRI Image

Search Result 941, Processing Time 0.028 seconds

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

Magnetic Resonance Findings in Two Episodes of Repeated Cerebral Fat Embolisms in a Patient with Autologous Fat Injection into the Face

  • Lee, Kyung-Mi;Kim, Eui-Jong;Jahng, Geon-Ho;Chang, Dae-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.5
    • /
    • pp.312-315
    • /
    • 2012
  • We report magnetic resonance image (MRI) and magnetic resonance spectroscopy (MRS) findings in a patient of cerebral fat embolism (CFE) occurred in a 26-year-old woman after an autologous fat injection into the face. After initial neurologic symptom onset, MRI and MRS data were obtained two times to investigate repeated CFE. We obtained the MRS data in the two different time intervals and two different echo times to compare the lesions with normal brain parenchyma. The results of MRS data showed that a decrease in N-acetyl-aspartate, an increase in lactate and a very high early peak of free lipids between 0.9 and 1.4 ppm were obtained at the acute infarcted lesion as compared with normal brain parenchyma. In addition, these findings were more clearly detected on short echo time spectrum rather than long spectrum. A close relationship between the clinical manifestations and MRI and MRS findings of the brain can helpful to distinguish CFE with other conditions and to evaluate the cause materials of infarctions rather than conventional MRI or diffusion-weighted imaging.

Peach & Pit Volume Measurement and 3D Visualization using Magnetic Resonance Imaging Data (자기공명영상을 이용한 복숭아 및 씨의 부피 측정과 3차원 가시화)

  • 김철수
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.227-234
    • /
    • 2002
  • This study was conducted to nondestructively estimate the volumetric information of peach and pit and to visualize the 3D information of internal structure from magnetic resonance imaging(MRI) data. Bruker Biospec 7T spectrometer operating at a proton reosonant frequency of 300 MHz was used for acquisition of MRI data of peach. Image processing algorithms and visualization techniques were implemented by using MATLAB (Mathworks) and Visualization Toolkit(Kitware), respectively. Thresholding algorithm and Kohonen's self organizing map(SOM) were applied to MRI data fur region segmentation. Volumetric information were estimated from segemented images and compared to the actual measurements. The average prediction errors of peach and pit volumes were 4.5%, 26.1%, respectively for the thresholding algorithm. and were 2.1%, 19.9%. respectively for the SOM. Although we couldn't get the statistically meaningful results with the limited number of samples, the average prediction errors were lower when the region segmentation was done by SOM rather than thresholding. The 3D visualization techniques such as isosurface construction and volume rendering were successfully implemented, by which we could nondestructively obtain the useful information of internal structures of peach.

Computer Tomography and Magnetic Resonance Image Manifestations of Primary Hepatic Neuroendocrine Cell Carcinomas

  • Huang, Juan;Yu, Jian-Qun;Sun, Jia-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2759-2764
    • /
    • 2014
  • Aim: This study aims to investigate the manifestation of CT, MRI and dynamic enhanced scans for primary hepatic neuroendocrine cell carcinoma. Methods: CT or MRI arterial and venous phase scan images of 19 cases of pathologically confirmed PHNEC were retrospectively analyzed. Results: 14 cases (73.68%) with single lesion, 5 cases (26.3%) with multiple lesions, with an average diameter of 13.2 cm. Some 12 cases (63.16%) showed inhomogeneous enhancement, seven cases (36.8%) showed homogeneous enhancement, 13 cases (68.4%) demonstrated significant enhancement in the arterial phase, 13 cases (68.4%) had significantly enhanced portal venous phase including 7 cases (36.8 %) with portal venous phase density or signal above the arterial phase and 5 cases (26.3%) with the portal vein density or signal below the arterial phase. Seven cases (36.8%) had continued strengthened separate shadows in the center of the lesion. Thrombosis were not seen in portal veins. Conclusion: CT and MRI images of liver cell neuroendocrine carcinoma have certain characteristics that can provide valuable information for diagnosis and differential diagnosis.

Observation between Clinical Outcomes and the Size of the Syrinx with Magnetic Resonance Image

  • Hwang, Ju-Yeon;Kim, Young-Jin;Oh, Seong-Hoon;Kang, Jae-Kyu;Kim, Young-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.169-174
    • /
    • 2006
  • Objective : This study was conducted to examine the correlation between clinical outcomes and the size of the syrinx in post-operative magnetic resonance imaging[MRI] and symptom duration. Methods : The authors investigated twelve patients who underwent various operations for syringomyelia from January 1995 to December 2003. The authors retrospectively analyzed medical records. pre- and post-operative MRI findings, features and durations of symptoms, and the method of surgical treatments. The clinical outcomes were assessed on Prolo scale at 6 months of post-operative period. Results : Neurologic symptoms did not promptly disappear after the shrinkage of syrinx, but post-operative MRI demonstrated most patients showed reductions in the size of the syrinx. There is no statistical relationship between clinical improvements and decrements of the syrinx size. However, patients who underwent surgical treatment within 2 years from the symptom onset had more favorable outcome than those who had operations after 2 years from the onset of symptoms. Conclusion : Change in the size of the syrinx in post-operative MRI is not directly proportional to favorable clinical outcomes. However, symptom duration before surgical treatment has considerable impact on the clinical outcomes.

Compressed-Sensing Cardiac CINE MRI using Neural Network with Transfer Learning (전이학습을 수행한 신경망을 사용한 압축센싱 심장 자기공명영상)

  • Park, Seong-Jae;Yoon, Jong-Hyun;Ahn, Chang-Beom
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1408-1414
    • /
    • 2019
  • Deep artificial neural network with transfer learning is applied to compressed sensing cardiovascular MRI. Transfer learning is a method that utilizes structure, filter kernels, and weights of the network used in prior learning for current learning or application. The transfer learning is useful in accelerating learning speed, and in generalization of the neural network when learning data is limited. From a cardiac MRI experiment, with 8 healthy volunteers, the neural network with transfer learning was able to reduce learning time by a factor of more than five compared to that with standalone learning. Using test data set, reconstructed images with transfer learning showed lower normalized mean square error and better image quality compared to those without transfer learning.

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Preparation of Chitosan-coated Magnetite Nanoparticles by Sonochemical Method for MRI Contrast Agent

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Choi, Eun-Jung
    • Journal of Magnetics
    • /
    • v.14 no.3
    • /
    • pp.124-128
    • /
    • 2009
  • Magnetic nanoparticles were synthesized by using the sonochemical method with oleic acid as a surfactant. The average size of the magnetite nanoparticles was controlled by varying the ratio R=[$H_2O$]/[surfactant] in the range of 2 to 9 nm. To prepare chitosan-coated magnetite nanoparticles, chitosan solution was added to a magnetite colloid suspension under ultrasonication at room temperature for 20 min. The chitosan-coated magnetite nanoparticles were characterized by several techniques. Atomic force microscopy (AFM) was used to image the chitosan-coated nanoparticles. Magnetic hysteresis measurement was performed by using a superconducting quantum interference device (SQUID) magnetometer to investigate the magnetic properties of the magnetite nanoparticles and the chitosan-coated magnetite nanoparticles. The SQUID measurements revealed the superparamagnetism of both nanoparticles. The T1- and T2-weighted MR images of these chitosan-coated magnetite colloidal suspensions were obtained with a 4.7 T magnetic resonance imaging (MRI) system. The chitosancoated magnetite colloidal suspensions exhibited enhanced MRI contrasts in vitro.

Remotely controlled Interactive Magnetic Resonance Imaging in Network Environment (Network을 이용한 원격 핵자기 공명 영상)

  • Park, J.I.;Kim, C.Y.;Park, D.J.;Ryu, W.S.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1383-1385
    • /
    • 1996
  • A network based interactive magnetic resonance imaging (MRI) system has been developed using the World Wide Web. For this purpose, an HTTP server is developed on the host computer of the MRI system. Capabilities of video and audio conferencing are included for monitoring experiment. Using the developed system. MRI imaging has been successfully carried out at the Signal Processing Lab in the Kwangwoon University with the remote MRI system located at the Medical Image Research Center at the KAIST in Daejon.

  • PDF