• Title/Summary/Keyword: MRI Examination

Search Result 469, Processing Time 0.022 seconds

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

Additive Manufacturing of TMJ Device used in Temporomandibular Joint MRI Scan by using 3D Printer (3D 프린터를 이용하여 턱관절 MRI검사에 사용되는 TMJ device제작)

  • Jang, Hye-Won
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.7
    • /
    • pp.628-634
    • /
    • 2018
  • In an examination of the temporomandibular joint disc, MRI(Magnetic Resonance Imaging) is a useful method, and it is necessary to conduct an examination with one's mouth open for a long time to observe the accurate position change of the disc. Thus, this study would produce a TMJ device, using the 3-D printing technology, which would maintain the state of opening the mouth and would evaluate its usefulness as compared to the existing fixed device. As compared to the image using the existing TMJ device, the image taken with the self-produced TMJ device with a 3-D printer showed a somewhat lower SNR, but there was no defect for a clinical use. It is judged that benefits to costs would increase, since it can be customized for the individual patient and can contribute to the production of similar tools by utilizing the 3-D printing technology.

The Clinical Usefulness of Electroencephalography : Comparison of Findings Electroencephalography with Findings of Brain Computed Tomography and Magnetic Resonance Imaging (뇌파의 임상적 유용성 : 뇌파소견과 뇌전산화 단층촬영 검사 및 뇌자기공명 영상검사 소견을 비교하여)

  • Kang, Dong-Woo;Lee, Young-Ho;Choi, Young-Hee;Chung, Young-Cho
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.1-17
    • /
    • 1996
  • To demonstrate the clinical usefulness of electroencephalography (EEG) and factors increasing the usefulness of EEG, the authors evaluated each relationship between EEG related factors and clinical variables, and neuroimaging studies (CT and MRI)-related factors, and factors which are related with routine neurological examination for 207 patients who had been evaluated with both of EEG and neuroimaging study(CT or/and MRI). The results were as follows: 1) Abnormality of EEG findings had significant relationships with chief complaints, diagnosis, medication use, seizure attack, pathological reflex, and level of consciousness. However there were no significant correlations between abnormality of EEG findings and neuroimaging studies (CT and MRI)- related factors. 2) Laterality of EEG findings had significant relationships with abnormality, laterality, and focality of CT findings, and also with abnormality of MRI findings. But there were no significant correlations between laterality of EEG findings and clinical variables, and neurological examination-related factors. 3) Anterior-posterior distribution of EEG findings was significantly related with medication use. 4) Focality of EEG findings had significant relationships with sex, sensory dysfunction sign, and cerebellar dysfunction sign. But there were no significant correlations between focality of EEG findings and neuroimaging studies(CT and MRI) related factors. 5) Abnormal EEG pattern had significant correlations with various factors, such as age, chief complaints, duration from onset of symptom to taking MRI, seizure attack, abnormality and nature of lesion in CT findings, cortical atrophy in MRI findings, motor dysfunction sign, sensory dysfunction sign, and pathological reflex. 6) With abnormality on sleep activation, age, age of onset, seizure attack, ventricular enlargement in CT findings, and abnormality of MRI findings were significantly correlated. 7) With abnormality on hyperventilation activation, duration of illness and laterality of MRI findings were significantly correlated. Above results may suggest that abnormality of EEG findings is more closely related with functional change of the brain than structural changes of the brain and laterality of EEG findings is vice versa. And also that medication use has an influence on anterior versus posterior distribution of EEG findings and focality of EEG findings is not related with structural changes of the brain. Activation with sleep may be effective to show age differences and provocation of seizure activity and hyperventilation may be effective to detect the abnormal EEG findings by cerebrovascular insufficiency.

  • PDF

Correlation between Magnetic Resonance Image Signal Changes and Electromyographic Findings after Sciatic Nerve Transection in the Rat (백서의 좌골신경 절단 후 비복근의 자기공명영상 신호강도 변화와 근전도 소견의 관계)

  • Lee, Joo Hwan;Lee, Jang Chul;Kim, Dong Won;Park, Ki Young;Lee, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • Objectives : The evaluation of peripheral nerve injuries has traditionally relied on a clinical history, physical examination, and electrodiagnostic studies. The purpose of the present study was to examine serial magnetic resonance image(MRI) changes following acute muscle denervation under experimental conditions and to identify potential advantages and disadvantages of this use of MRI. Methods : An experimental transection of right sciatic nerve on Spargue-Dawley rats was performed. MRI was performed with T1-weighted spin-echo and STIR sequences. The imaging findings were compared with EMG in order to determine its sensitivity relative to this standard procedure. A simultaneous histopathological study provided information about the morphological basis of the imaging findings. Signal intensities were expressed as a ratio of abnormal to normal. Results : The signal intensity ratio of muscles with the STIR sequence was increased significantly at 2 weeks after sciatic nerve transection(p<0.05), although definite signal change was seen as early as 4 days postdenervation in one. EMG revealed significant denervation potential from 3 days after nerve transection. Diffuse cell atrophy was revealed hostologically at 2 weeks after transection, which was at the same time of significant signal change in MRI. Conclusion : MRI signal changes in denervated muscles secondary to nerve injury correlate with the degree of muscle atrophy on histologic examination. In addition to EMG, MRI can document the course of muscle atrophy and mesenchymal abnormalities in denervation. These results indicate that MRI can play a complementary role in the evaluation of patients with denervation.

  • PDF

Clinical Study for Patients with Lumbar Disc Herniation on Change of Magnetic Resonance Imaging at One Year after Conservative Treatment (요추 추간판 탈출증 환자의 보존적 치료 후 변화된 자기공명영상에 따른 1년 후 임상변화 고찰)

  • Kwon, Hyeok-Joon;Park, Young-Hoi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.253-263
    • /
    • 2011
  • Objectives : To analyze the therapeutic outcomes of back pain modalities in patients with disc herniation according to the change of magnetic imaging(MRI) at one year after conservative treatment. Methods : Clinical outcomes of 35 patients diagnosed with lumbar disc herniation by MRI examination, treated conservatively, were analyzed according to MRI follow-up change; improved, unchanged, worsened. Patients underwent MRI examination at baseline and after 24 week of treatment. After 1 year, we followed up 30 patients. The patients' clinical outcomes were assessed at baseline, 24 week, 1 year by visual analogue scale(VAS), oswestry disability index (ODI), and analyzed by each of it's correlation. Results : 1. VAS of sciatica and ODI of disability of daily activities showed significant decrease in patients after 1 year follow up(p<0.05). 2. VAS(low back pain and sciatica) and ODI of disability of daily activities showed significant decrease in "improved" group and VAS(sciatica) and ODI showed significant decrease in "unchanged" group. "worsened" group showed no statistic significance(p<0.05). 3. The 1 year follow-up of VAS(low back pain and sciatica) and ODI change showed relationship with MRI follow-up change(p<0.05). Conclusions : This study suggests that "improved" groups compared to "unchanged" and "worsened" group on MRI follow-up in patients with lumbar disc herniation were more effective at 1 year after conservative treatment. MRI follow-up change affect clinical changes in patients with lumbar disc herniation after 1 year.

The Effects of the Communication Accompanied with Music Therapy on the Anxiety of the Patients during the MRI Examination (MRI 검사 시 음악요법을 동반한 의사소통이 환자의 불안에 미치는 영향)

  • Yoon, Yong-Hak;Yoon, Hee-Jung;Lee, Sung-Kook;Kim, Kyung-Hee;Kwon, Gi-hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.93-102
    • /
    • 2016
  • This study examined effects of the communication accompanied with music therapy on the anxiety of patients during a MRI examination. In the experiment group consisting of thirty patients and the control group consisting of thirty patients, the experiment was performed from February 1st 2014 to March 31st 2014 in hospital C located in Daegu Korea. The research design was a non-equivalent control group quasi-experimental study. The results showed that the anxiety score (VAS score) on communication with music therapy of the experimental group was significantly lower (p=.001), than that of the control group. Among the vital signs, the blood pressure was similar in both groups. On the other hand, the pulse rate of the experiment group was significantly lower (p=.001). Four categories of the physical discomfort (perspiration, facial change, change in physical posture, and change in vocal sound) did not show any statistically significant difference between the control and experiment group. Among the mental discomforts, dizziness did not have a significant difference between the experiment group and the control group, but the experimental group had significantly low fear (p=.001) and anxiety (p=.001). From the above results, communication accompanying music therapy proves is an effective alternative examination method that reduces the anxiety of patients.

Abbreviated Magnetic Resonance Imaging for Breast Cancer Screening: Concept, Early Results, and Considerations

  • Eun Sook Ko;Elizabeth A. Morris
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.533-541
    • /
    • 2019
  • Breast magnetic resonance imaging (MRI) has been increasingly utilized, especially in screening for high-risk cases, because of its high sensitivity and superior ability to detect cancers as compared with mammography and ultrasound. Several limitations such as higher cost, longer examination time, longer interpretation time, and low availability have hindered the wider application of MRI, especially for screening of average-risk women. To overcome some of these limitations and increase access to MRI screening, an abbreviated breast MRI protocol has been introduced. Abbreviated breast MRI is becoming popular and challenges the status quo. This review aims to present an overview of abbreviated MRI, discuss the current findings, and introduce ongoing prospective trials.

Recent Updates of Abbreviated MRI for Hepatocellular Carcinoma Screening (간세포암 감시를 위한 단축 자기공명영상의 최신지견)

  • Jeong Woo Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.280-297
    • /
    • 2021
  • International guidelines recommended screening with ultrasonography (US) every 6 months for patients at risk for hepatocellular carcinoma (HCC). However, US demonstrates low sensitivity for the early detection of HCC. Magnetic resonance imaging (MRI) plays an important role in the noninvasive diagnosis of HCC, but it is not suitable for surveillance due to its lengthy examination and high cost. Therefore, several studies have been using various abbreviated MRI strategies, including noncontrast abbreviated MRI, dynamic contrast-enhanced abbreviated MRI, and abbreviated MRI using hepatobiliary phase image for HCC surveillance. In this article, we aim to review these various strategies and explore the future direction of HCC surveillance considering the cost-effectiveness aspect.

Spontaneous Rupture of Proximal Rectus Femoris: A case report (근위부 대퇴직근의 자연 파열 - 증례보고 -)

  • Jeon, In-Ho;Kyung, Hee-Soo;Lee, Sang-Won;Kim, Poong-Taek
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.81-84
    • /
    • 2006
  • Rupture of the rectus femoris at the musculotendinous junction is very rarely reported in the literature, especially which is caused by chronic repetitive stimulation. A 21 year old soldier complained of progressing right thigh pain and mass for 8 weeks after military training. MRI of the right thigh showed inhomogenous mass lesion suspecting soft tissue tumor. However ultrasonographic examination showed torn retracted rectus femoris tendon at musculotendinous junction. One year after primary repair of ruptured tendon, the patient is free from symptoms and returned to full previous activities. Knowledge of this sonographic and MRI finding will help the surgeon to diagnose and treat this rare injury.

  • PDF

A Study on the Performance Improvement for Magnetic Resonance Imaging Examination by Using the 6-Sigma Application (6-시그마 기법을 이용한 자기공명영상 검사 실적 개선에 대한 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.243-249
    • /
    • 2011
  • The purpose of the study was to improve of performance for Magnetic Resonance Imaging (MRI) examination in the department of radiology. It was performed DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, The fifth kinds of CTQ (critical to quality) by the kindness, the waiting time, the examination explanation, the waiting time and the waiting environment were selected by voice of customer. In the stage of measurement, the performed examinations and the reservation waiting time were measured each 1.77 and 1.69 sigma. In the stage of analysis, the potential key causes were determined the limited working hours and the difference of examination time of various entries. In the stage of improvement, MRI were performed with the operating system of 24 hours examination and the optimization of the difference of examination time by among of 30 minutes, 40 minutes, 50 minutes. Finally, the number of examinations and reserved waiting days were measured by each 3.17 and 1.71 sigma in the control stage.