• Title/Summary/Keyword: MRI(magnetic resonance imaging)

Search Result 2,027, Processing Time 0.03 seconds

Design and Implementation of Microstrip Quadrature Coupler and High Power Transmitting/Receiving Switch Using Dynamic Loading Technique for 1-Tesal MRI System (동적 부하 기술을 이용한 1-Tesla 자기공명 영상 시스템용 마이크로 스트립 quadrature coupler 및 고출력 송수신 스위치의 설계 및 제작)

  • 류웅환;이미영;이흥규;이황수;김정호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.1-11
    • /
    • 1999
  • It is now common practice to utilize the quadrature RF coils to improve the signal-to-noise ratio (SNR) in the Magnetic Resonance Imaging (MRI) System. In addition, to make such an available SNR improvement, it is mandatory to use a well-designed quadrature coupler, which facilitates a perfect 3-dB coupling and quadrature-phase shift. However, the four ports matching condition has to be well considered during the RF excitation and the signal detection period. This work investigates the effects of such a mismatching condition (especially, due to patient) from the analysis, simulation, and real implementation and firstly proposes dynamic loading technique for a quadrature coupler and transmitting/receiving switch module to minimize a patient mismatching and enhance a system reliability. Also, we designed and implemented the quadrature coupler and transmitting/receiving switch module using microstrip. As a result, the SNR of our MRI system using the microstrip quadrature coupler and transmitting/receiving switch module with dynamic load increases 3 dB compared with the old one using USA quadrature switch. Also, the power capability of quadrature coupler and transmitting/receiving switch module is 5-kw peak power. Considering power loss and reduction of size, we used a RT/duroid 6010 substrate with high permittivity and for simulation we use Compact Software.

  • PDF

Resection and Observation for Brain Metastasis without Prompt Postoperative Radiation Therapy

  • Song, Tae-Wook;Kim, In-Young;Jung, Shin;Jung, Tae-Young;Moon, Kyung-Sub;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.667-675
    • /
    • 2017
  • Objective : Total resection without consecutive postoperative whole brain radiation therapy is indicated for patients with a single or two sites of brain metastasis, with close follow-up by serial magnetic resonance imaging (MRI). In this study, we explored the effectiveness, usefulness, and safety of this follow-up regimen. Methods : From January 2006 to December 2015, a total of 109 patients (76 males, 33 females) underwent tumor resection as the first treatment for brain metastases (97 patients with single metastases, 12 with two metastases). The mean age was 59.8 years (range 27-80). The location of the 121 tumors in the 109 patients was supratentorial (n=98) and in the cerebellum (n=23). The origin of the primary cancers was lung (n=45), breast (n=17), gastrointestinal tract (n=18), hepatobiliary system (n=8), kidney (n=7), others (n=11), and unknown origin (n=3). The 121 tumors were totally resected. Follow-up involved regular clinical and MRI assessments. Recurrence-free survival (RFS) and overall survival (OS) after tumor resection were analyzed by Kaplan-Meier methods based on clinical prognostic factors. Results : During the follow-up, MRI scans were done for 85 patients (78%) with 97 tumors. Fifty-six of the 97 tumors showed no recurrence without adjuvant local treatment, representing a numerical tumor recurrence-free rate of 57.7%. Mean and median RFS was 13.6 and 5.3 months, respectively. Kaplan-Meier analysis revealed the cerebellar location of the tumor as the only statistically significant prognostic factor related to RFS (p=0.020). Mean and median OS was 15.2 and 8.1 months, respectively. There were no significant prognostic factors related to OS. The survival rate at one year was 8.2% (9 of 109). Conclusion : With close and regular clinical and image follow-up, initial postoperative observation without prompt postoperative radiation therapy can be applied in patients of brain metastasi(e)s when both the tumor(s) are completely resected.

Gamma Knife Radiosurgery for Brainstem Metastasis

  • Yoo, Tae-Won;Park, Eun-Suk;Kwon, Do-Hoon;Kim, Chang-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.299-303
    • /
    • 2011
  • Objective : Brainstem metastases are rarely operable and generally unresponsive to conventional radiation therapy or chemotherapy. Recently, Gamma Knife Radiosurgery (GKRS) was used as feasible treatment option for brainstem metastasis. The present study evaluated our experience of brainstem metastasis which was treated with GKRS. Methods : Between November 1992 and June 2010, 32 patients (23 men and 9 women, mean age 56.1 years, range 39-73) were treated with GKRS for brainstem metastases. There were metastatic lesions in pons in 23, the midbrain in 6, and the medulla oblongata in 3 patients, respectively. The primary tumor site was lung in 21, breast in 3, kidney in 2 and other locations in 6 patients. The mean tumor volume was $1,517mm^3$ (range, 9-6,000), and the mean marginal dose was 15.9 Gy (range, 6-23). Magnetic Resonance Imaging (MRI) was obtained every 2-3 months following GKRS. Follow-up MRI was possible in 24 patients at a mean follow-up duration of 12.0 months (range, 1-45). Kaplan-Meier survival analysis was used to evaluate the prognostic factors. Results : Follow-up MRI showed tumor disappearance in 6, tumor shrinkage in 14, no change in tumor size in 1, and tumor growth in 3 patients, which translated into a local tumor control rate of 87.5% (21 of 24 tumors). The mean progression free survival was 12.2 months (range, 2-45) after GKRS. Nine patients were alive at the completion of the study, and the overall mean survival time after GKRS was 7.7 months (range, 1-22). One patient with metastatic melanoma experienced intratumoral hemorrhage during the follow-up period. Survival was found to be associated with score of more than 70 on Karnofsky performance status and low recursive partitioning analysis class (class 1 or 2), in terms of favorable prognostic factors. Conclusion : GKRS was found to be safe and effective for management of brainstem metastasis. The integral clinical status of patient seems to be important in determining the overall survival time.

3-Dimensional Dosimetry of Small Field Photon Beam (광자선의 소조사면에서의 3차원적 선량 측정)

  • Jang, Ji-Sun;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2012
  • A polymer gel dosimeter was fabricated. A 3-dimensional dosimetry experiment was performed in the small field of the photon of the cyberknife. The dosimeter was installed in a head and neck phantom. It was manufactured from the acrylic and it was used in dosimetry. By using the head and neck CT protocol of the CyberKnife system, CT images of the head and neck phantom were obtained and delivered to the treatment planning system. The irradiation to the dosimeter in the treatment planning was performed, and then, the image was obtained by using 3.0T magnetic resonance imaging (MRI) after 24 hours. The dose distribution of the phantom was analyzed by using MATLAB. The results of this measurement were compared to the results of calculation in the treatment planning. In the isodose curve on the axial direction, the dose distribution coincided with the high dose area, 0.76mm difference on 80%, rather than the low dose area, 1.29 mm difference on 40%. In this research, the fact that the polymer gel dosimeter and MRI can be applied for analyzing a small field in a 3 dimensional dosimetry was confirmed. Moreover, the feasibility of using these for the therapeutic radiation quality control was also confirmed.

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Activation Differences of Superior Parietal Lobule and Cerebellum Areas While Inferring Geometrical Figures per Intellectual Category in Adolescents (도형 과제 수행 때 나타나는 청소년의 지능별 대뇌 및 소뇌의 활성도 차이 분석)

  • Kim, Ye Rim
    • Journal of Gifted/Talented Education
    • /
    • v.23 no.5
    • /
    • pp.637-648
    • /
    • 2013
  • The relationship between the cerebral cortex and human intelligence has been studied using various methods, and related brain areas involved in intellectual manifestation have been discovered individually. Such studies have also shown the cerebellum is closely involved in various cognitive functions such as language, memory, and information processing. However, studies showing an activity difference between the cerebral cortex and cerebellum when performing specific tasks are hard to find. This study searched and analyzed the active regions of the cerebral cortex and cerebellum seen while performing the inference of geometrical figures. A WAIS intelligence test was conducted using 81 healthy boys (16.3 years of age on average), and five categories were classified. While performing the inference of shapes, their brain images were taken using functional magnetic resonance imaging (fMRI). As a result, the activity in 12 brain regions was observed, including in the cerebral cortex, the bilateral inferior parietal, the visual cortex, bilateral superior parietal, frontal-Inf-Tri-R, and bilateral caudate, while activities in 5 discrete areas were seen in the cerebellum. In particular, the higher the intelligence (IQ) of the subject, the stronger their activity. Among those with the most superior intelligence, subjects with an IQ of 140-147 showed significantly higher activity compared to the other groups. Such results seem to represent a very high utilization of intelligence in a highly gifted group, and we can expect to use this to determine the super gifted.

Clinical Outcome and Causative Factor in Patients of Structural Failure after Rotator Cuff Repair (회전근 개 파열 봉합술 후 재파열 환자에서 임상결과와 원인 인자)

  • Chun, Jae-Myeung;Song, Jung-Suk;Sohn, Dong-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 2008
  • Purpose: We wanted to evaluate the relationship between the clinical outcomes and cuff integrity after open rotator cuff repair and we wanted to analyze the causes of rotator cuff retear. Materials and Methods: 78 patients who underwent open rotator cuff repair were enrolled from 2004 to 2006. All the patients were observed for a minimum follow-up of 12 months and they were evaluated by magnetic resonance imaging (MRI). The clinical outcomes were accessed by dividing the patients into the retear group and the intact group. The groups were also compared to analyze the cause of rotator cuff retear according to the preoperative tear size, the symptom duration, and so on. Results: The clinical outcome of the retear group (n=22) was improved significantly after operation (p<0.001, p<0.001), but the muscle power was not improved significantly (p=0.099, p=0.243). More retears were found in the patients who had a larger preoperative tear (p<0.001) and the symptom duration of the retear group was longer (p=0.027). Conclusion: Although there were retear after rotator cuff repair, the clinical outcomes were improved. Yet the muscle power of the supraspinatus and external rotator were not improved significantly. There were more retears for the cases that had a larger preoperative tear size and a longer duration of symptoms.

Combined MRI and Relaxogram: A New Method of Fat Study (MRI와 Relaxogram을 이용한 지질 연구의 새로운 기법에 관한 연구)

  • Yongmin Chang;Yoo, Done-Sik;Kim, Tae-Hun;Kim, Yong-Joo;Kang, Duk-Sik;Robert B. Clarkson
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.23-32
    • /
    • 1999
  • Combined MRI and Relaxogram approach was introduced as a very useful tool for fat study. The phantoms simulating homogeneous mixture of fat and non-fat environments were measured with spin echo pulse sequence on a 0.15 T whole body imager. From 45 scans, the Tl values were obtained by fitting the data to continuous distribution (CONTIN) of relaxation time. This relaxogram gives broad distributions of relaxation time, which are characterized by a number of peaks with characteristic T1 values. Two distinct peaks in relaxogram were observed and identified as signals from com oil and gelatin gel. This model system can be served as simulating the distribution of fat in muscle. Also the relative ratio of two components, which is proportional to the area under the peak, is estimated and compared to nominal values. Based on the good agreement between two predictions, the values from our proposed method agreed with nominal values within $\pm$7 % error. The effects of different concentration of contrast agent and different region of interest are presented. To optimize total scan times, the minimum required data points and so further reduction in total scan times are discussed.

  • PDF

Comparison of Proton T1 and T2 Relaxation Times of Cerebral Metabolites between 1.5T and 3.0T MRI using a Phantom (모형을 이용한 1.5T와 3.0T 자기공명에서의 뇌 대사물질들의 수소 T1과 T2 이완시간의 비교)

  • Kim, Ji-Hoon;Chang, Kee-Hyun;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose : To present the T1 and T2 relaxation times of the major cerebral metabolites at 1.5T and 3.0T and compare those between 1.5T and 3.0T. Materials and Methods : Using the phantom containing N-acetyl aspartate (NAA), Choline (Cho), and Creatine (Cr) at both 1.5T and 3.0T MRI, the T1 relaxation times were calculated from the spectral data obtained with 5000 ms repetition time (TR), 20 ms echo time (TE), and 11 different mixing time (TM)s using STEAM (STimulated Echo-Acquisition Mode) method. The T2 relaxation times were obtained from the spectral data obtained with 3000 ms TR and 5 different TEs using PRESS (Point-RESolved Spectroscopy) method. The T1 and T2 relaxation times obtained at 1.5T were compared with those of 3.0T. Results : The T1 relaxation times of NAA were $2293\;{\pm}\;48\;ms$ at 1.5T and $2559\;{\pm}\;124\;ms$ at 3.0T (11.6% increase at 3.0T). The T1 relaxation times of Cho were $2540\;{\pm}\;57\;ms$ at 1.5T and $2644\;{\pm}\;76\;ms$ at 3.0T (4.1% increase at 3.0T). The T1 relaxation times of Cr were $2543\;{\pm}\;75\;ms$ at 1.5T and $2665\;{\pm}\;94\;ms$ at 3.0T (4.8% increase). The T2 relaxation times of NAA were $526\;{\pm}\;81\;ms$ at 1.5T and $468\;{\pm}\;74\;ms$ at 3.0T (11.0% decrease at 3.0T). The T2 relaxation times of Cho were $220\;{\pm}\;44ms$ at 1.5T and $182\;{\pm}\;35\;ms$ at 3.0T (17.3% decrease at 3.0T). The T2 relaxation times of Cr were $289\;{\pm}\;47\;ms$ at 1.5T and $275\;{\pm}\;57\;ms$ at 3.0T (4.8% decrease at 3.0T). Conclusion : The T1 relaxation times of the major cerebral metabolites (NAA, Cr, Cho), which were measured at the phantom, were 4.1%-11.6% longer at 3.0T than at 1.5T. The T2 relaxation times of them were 4.8%-17.3% shorter at 3.0T than at 1.5T. To optimize MR spectroscopy at 3.0T, TR should be lengthened and TE should be shortened.

  • PDF