• Title/Summary/Keyword: MR ratio

Search Result 449, Processing Time 0.024 seconds

An Efficient Segmentation-based Wavelet Compression Method for MR Image (MR 영상을 위한 효율적인 영역분할기반 웨이블렛 압축기법)

  • 문남수;이승준;송준석;김종효;이충웅
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.339-348
    • /
    • 1997
  • In this paper, we propose a coding method to improve compression efficiency for MR image. This can be achieved by combining coding scheme and segmentation scheme which removes noisy background region, which is meaningless for diagnosis in the MR image. In segmentation algoritm, we use full-resolution wavelet transform to extract features of regions in image and Kohonen self-organizing map to classify the features. The subsequent wavelet coder encodes only diagnostically significant foreground regions refering to segmentation map. Our proposed algorithm provides about 15% of bit rate reduction when compared with the same coder which is not combined with segmentation scheme. And the proposed scheme shows better reconstructed image quality than JPEG at the same compression ratio.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Segmentation-based Wavelet Coding Method for MR Image (MR 영상의 영역분할기반 웨이블렛 부호화방법)

  • Moon, N.S.;Lee, S.J.;Song, J.S.;Kim, J.H.;Lee, C.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.95-100
    • /
    • 1997
  • In this paper, we propose a coding method to improve compression efficiency for MR image. This can be achieved by combining coding and segmentation scheme which removes noisy background region, which is meaningless for diagnosis, in MR image. The wavelet coder encodes only diagnostically significant foreground regions refering to segmentation map. Our proposed algorithm provides about 15% of bitrate reduction when compared with the same coder which is not combined with segmentation scheme. And the proposed scheme shows better reconstructed image Qualify than JPEG at the same compression ratio.

  • PDF

Fundamental Background for 3T MRI/MRS

  • Choe, Bo-Young
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.47-49
    • /
    • 2002
  • At present, the trend of magnetic field strength in MRI system is dramatically changing. In early 70, the only low field (<0.5T) was developed. It was technically difficult to develop the high field system. At that time, people believed that the fine MR imaging could not be obtained in the high field MR system due to the magnetic susceptibility effect. However, 1.5T system was evolved at the end of 80, and used for clinical usage. Thus, it was proved that the signal to noise ratio (SNR) could be greatly contribute to enhance the image quality. And, the results of functional MRI and MR spectroscopy could be improved in the higher field MR system. So, 8T system was eventually developed in Ohio State University Hospital at the end of 90. Therefore, there is no doubt that the system with the ultra high magnetic field strength will be developed near future in 21 century.

  • PDF

A Study on the Structural and Magnetoresistance Properties of Co/Ag Multilayers (Co/Ag 다층박막의 구조 및 자기저항 현상에 관한 연구)

  • 이용규;이성래
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.86-92
    • /
    • 1996
  • The structural, magnetic and magnetoresistance properties of Co/Ag multilayer films prepared by thermal coevaporation were studied. When the Ag layer was $60{\AA}$ thick, the Co layer behaved ferromagnetically even with the thickness of $5{\AA}$. However, when the thickness of Ag layer was $30{\AA}$ and that of Co layer was less than $15{\AA}$ thick, the Co layer became discontinuous and the islands of Co behaved mostly superpararnagnetically. The maximum MR ratio, 6.1% was obtained in the $3000{\AA}\;Ag30{\AA}/Co10{\AA}$ Ag30 A ICo 10 A discontinuous multilayer. Agglomeration of the Co layer was promoted by annealing and hence MR ratio increased when the thickness of Ag layer was thinner than $15{\AA}$. The SiO underlayer enhanced the MR ratio in the $1000{\AA}$ thick multilayer via the layer structure improvement.

  • PDF

A Study on the Debrisoquine Metabolism in a Group of Korean Population (일부 한국인 Debrisoquine 대사분포에 대한 연구)

  • Lee, Myung-Hak;Moon, Hwa-Young;Son, Myung-Ho;Sohn, Seok-Joon;Choi, Jin-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.569-579
    • /
    • 1994
  • The genetically determined ability to metabolize debrisoquine (DBR) is related to risk of lung cancer and DBR hydroxylation exhibits wide inter-individual variation. In this study, 100 korean adults were tested for their ability to metabolize DBR. The DBR metabolic phenotype were determined by metabolic ratio (MR, DBR / 4-HDBR) which is the percent dose excreted as unchanged DBR divided by the percent dose excreted as 4-hydroxyebrisoquine(4-HDBR) in a aliquot of an eight hour urine sample, after 10mg DBR test dose administration. Analysis was performed on a capillary gas chromatograph fitted with electron capture detector. The results were as follows; 1 Geometric mean of DBR MR was 0.32 in male,0.27 in female,0.30 in total and the distribution of log (MR) was seemed to follow normal distribution. 2. Metabolic ratio of DBR was higher in non-smoker and non-drinker than in smoker and drinker without any statistically significant difference. 3. None of personal factors was significantly related to DBR MR except age. 4. The DBR metabolic phenotype was extensive metabolizer(EM) 93, intermediate metabolizer(IM) 7 by traditional method and EM 98, IM 3 by Caporaso's method. The poor metabolizer (PM) phenotype was not found by either method. 5. Maximal expected PM phenotype was 0.36% by traditional method and 0.04% by Caporaso's method.

  • PDF

Design formulas for vibration control of sagged cables using passive MR dampers

  • Duan, Yuanfeng;Ni, Yi-Qing;Zhang, Hongmei;Spencer, Billie F. Jr.;Ko, Jan-Ming;Dong, Shenghao
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.537-551
    • /
    • 2019
  • In this paper, a method for analyzing the damping performance of stay cables incorporating magnetorheological (MR) dampers in the passive control mode is developed taking into account the cable sag and inclination, the damper coefficient, stiffness and mass, and the stiffness of damper support. Both numerical and asymptotic solutions are obtained from complex modal analysis. With the asymptotic solution, analytical formulas that evaluate the equivalent damping ratio of the sagged cable-damper system in consideration of all the above parameters are derived. The main thrust of the present study is to develop an general design formula and a universal curve for the optimal design of MR dampers for adjustable passive control of sagged cables. Two sag-affecting coefficients are derived to reflect the effects of cable sag on the maximum attainable damping ratio and the optimal damper coefficient. For the cable configurations commonly used in cable-stayed bridges, the sag-affecting coefficients are directly expressed in terms of the sag-extensibility parameter to facilitate the control design. A case study on adjustable passive vibration control of the longest cable (536 m) on Stonecutters Bridge is carried out to demonstrate the influence of the sag for the damper design, and to figure out the necessity of adjustability of damper coefficients for achieving maximum damping ratio for different vibration modes.

A Study on Mixing Characterization of Unlike-doublet Injector for Liquid Rocket Engine (액체로켓용 Unlike-doublet 인젝터의 혼합특성 연구)

  • Lee, In-Su;Jung, Ki-Hoon;Lim, Byoung-Gjik;Yoon, Young-Bin
    • Journal of ILASS-Korea
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2002
  • The mixing of propellant and its mass distribution of unlike-doublet impinging injector, which is known to affect the combustion efficiency significantly, have been studied using PLIF(Planar Laser Induced Fluorescence). The results show that fuel jet penetrates considerably into the oxidizer jet at impinging point as variation of momentum ratio. and then stream flows inclined because of variation of momentum ratio. Consequently, the mixing efficiency shows that maximum efficiency is at MR=3. after MR=3, mining efficiency decreases slightly.

  • PDF

EFFECT OF THE ADDITION OF Ni ON GIANT MAGNETORESISTANCE OF Cu-Co AGED RIBBONS

  • Kim, I.J.;Echigoya, J.;Fukamichi, K.;Shimada, Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.456-460
    • /
    • 1995
  • Giant magnetoresistance(GMR) of $Cu_{85-x}Co_{15}Ni_{x}$ melt-spu ribbons is closely correlated with the microstructure produced by the spinodal decomposition. The solid solution range is extanded by the replacement of Cu by Ni in the as-quenched state. The wavelengths obtained by subsequent isothermal aging in Cu-Co-Ni ribbons are shorter than those in Cu-Co binary ribbons, resulting in the increase of the surface-to-volume ratio. The largest MR ratio of 8 % in high field has been achieved in the $Cu_{80}Co_{15}Ni_{5}$ aged ribbon. The field dependence of MR ratio in low fields becomes larger with the Ni content.

  • PDF

MR Characteristics of $Al_2O_3$ Based Magnetic tunneling Junction ($Al_2O_3$를 절연층으로 이용한 스핀 의존성 터널링 접합에서의 자기저항 특성)

  • 정창욱;조용진;정원철;조권구;주승기
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.3
    • /
    • pp.118-122
    • /
    • 2000
  • MR characteristics of $Al_2$ $O_3$ based magnetic tunneling juction with various $Al_2$ $O_3$ thicknesses were investigated. Spin-dependent tunneling junctions, in which the tunneling barrier $Al_2$ $O_3$ is formed by depositing a 1-3 nm thick Al layer, followed by thermal oxidation at room temperature in an $O_2$atmosphere, were fabricated on 4$^{\circ}$tilt(111)Si substrate in 3-gun magnetron sputtering system. The top and bottom ferromagnetic electrodes were Ni$_{80}$Fe$_{20}$ and Co. A maximum Tunneling MR ratio of 14% was obtained in the junction of which insulating barrier thickness was 2 nm. By increasing the tunneling voltage across the junction, maximum MR ratio reduced and finally showed no MR characteristics.s.

  • PDF