• Title/Summary/Keyword: MR ratio

Search Result 439, Processing Time 0.027 seconds

Full-scale experimental verification on the vibration control of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Liu, Jiangyun;Sun, Limin
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1003-1021
    • /
    • 2015
  • MR dampers have been proposed for the control of cable vibration of cable-stayed bridge in recent years due to their high performance and low energy consumption. However, the highly nonlinear feature of MR dampers makes them difficult to be designed with efficient semi-active control algorithms. Simulation study has previously been carried out on the cable-MR damper system using a semi-active control algorithm derived based on the universal design curve of dampers and a bilinear mechanical model of the MR damper. This paper aims to verify the effectiveness of the MR damper for mitigating cable vibration through a full-scale experimental test, using the same semi-active control strategy as in the simulation study. A long stay cable fabricated for a real bridge was set-up with the MR damper installed. The cable was excited under both free and forced vibrations. Different test scenarios were considered where the MR damper was tuned as passive damper with minimum or maximum input current, or the input current of the damper was changed according to the proposed semi-active control algorithm. The effectiveness of the MR damper for controlling the cable vibration was assessed through computing the damping ratio of the cable for free vibration and the root mean square value of acceleration of the cable for forced vibration.

Experimental study of controllable MR-TLCD applied to the mitigation of structure vibration

  • Cheng, Chih-Wen;Lee, Hsien Hua;Luo, Yuan-Tzuo
    • Smart Structures and Systems
    • /
    • v.15 no.6
    • /
    • pp.1481-1501
    • /
    • 2015
  • MR-TLCD (Magneto-Rheological Tuned Liquid Column Damper) is a new developed vibration control device, which combines the traditional passive control property with active controllability advantage. Based on traditional TLCD governing equation, this study further considers MR-fluid viscosity in the equation and by transforming the non-linear damping term into an equivalent linear damping, a solution can be obtained. In order to find a countable set of parameters for the design of the MR-TLCD system and also to realize its applicability to structures, a series of experimental test were designed and carried out. The testing programs include the basic material properties of the MR-fluid, the damping ratio of a MR-TLCD and the dynamic responses for a frame structure equipped with the MR-TLCD system subjected to strong ground excitations. In both the analytical and experimental results of this study, it is found that the accurately tuned MR-TLCD system could effectively reduce the dynamic response of a structural system.

A Study on Cost-Effectiveness Evaluation and Optimal Design of ant dampers for Cable-Stayed Bridges (사장교에 장착된 MR 댐퍼의 비용효율성 평가 및 최적설계 연구)

  • Park, Won-Suk;Hahm, Dae-Gi;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.47-56
    • /
    • 2006
  • A method is presented for evaluating the economic efficiency of a semi-active magneto-rheological (MR) damper system for cable-stayed bridges under earthquake loadings. An optimal MR damper capacity maximizing the cost-effectiveness is estimated for various seismic characteristics of ground motion. The economic efficiency of MR damper system is addressed by introducing the life-cycle cost concept. To evaluate the expected damage cost, the probability of failure is estimated. The cost-effectiveness index is defined as the ratio of the sums of the expected damage costs and each device cost between a bridge structure with the MR damper system and a bridge structure with elastic bearings. In the evaluation of cost-effectiveness, the scale of damage cost is adopted as parametric variables. The results of the evaluation show that the MR damper system can be a cost-effective design alternative. The optical capacity of MR damper is increased as the seismic hazard becomes severe.

Assessment of Malignancy in Brain Tumors by 3T MR Spectroscopy

  • 최보영;전신수;이재문;정성택;안창범;오창현;김선일;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.76-76
    • /
    • 2003
  • Purpose: To assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating tumor malignancy at 3T high field system. Methods: Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. Results: The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16:1:0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of high-grade gliomas was significantly higher than that of low-grade gliomas (P= 0.001), Except 4 menigiomas, lactate signal was observed in all tumor cases. Conclusions: The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy. Acknowledgement: This study was supported by a grant of the Mid and Long Term Nuclear R/D Plan Program, Ministry of Science and Technology, Republic of Korea.

  • PDF

Effects of CT Contrast Medium on the Relaxation Rate of MR Contrast Medium (CT 조영제가 MR 조영제의 이완율에 미치는 영향)

  • Kwon, Soon-Yong;Kang, Chung-Hwan;Jeong, Hyeon Keum;Park, Jin Seo;Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.103-107
    • /
    • 2018
  • In MR, the iodine CT contrast medium reduces the T1 and T2 relaxation times of the substance, resulting in a change in signal intensity. This study aimed to measure the relaxation rate of MR contrast medium with or without diluting CT contrast medium and analyzed the effect of CT contrast medium. Undiluted Gadoteridol solution was diluted with saline to prepare MR contrast medium phantoms with various levels of Gadoteridol concentrations. Moreover, undiluted Iomeprol was mixed with the prepared MR contrast medium phantoms at 1:1 ratio to make MR contrast medium phantoms with containing CT contrast medium for the experiment. T1 and T2 mappings were conducted to quantitatively evaluate the relaxation time and relaxation rate of these phantoms. The results showed that the T1 and T2 relaxation time and relaxation rate of MR contrast medium diluted with CT contrast medium were significantly (p<0.05) shorter than those of MR contrast medium not diluted with CT contrast medium. The results of this study imply that, when MR contrast medium shall be used after injecting CT contrast medium, CT contrast medium should be discharged enough. Moreover, it would be desirable to conduct CT test after taking MRI test in order to reduce the effects of CT contrast medium on MR contrast medium.

A Study on the Effect of Herbal-acupuncture with Mori Ramulus Solution at Joksamni(ST36) on Collagen-induced Arthritis (족삼리(足三里) 상지약침(桑枝藥鍼)이 Collagen-induced arthritis에 미치는 영향)

  • Jeong, Yeong-Don;Yim, Yun-Kyoung;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.23 no.6
    • /
    • pp.29-44
    • /
    • 2006
  • Objectives : The purpose of this study is to observe the effects of Mori Ramulus herbal-acupuncture solution(MR-HAS) on arthritis of mice induced by Collagen II at Joksamni(ST36). Methods : The author performed several experimental items. First, it is the cell survival rate of mice lung fibroblasts. Second, it is the incidence rate of arthritis and arthritis index of CIA. Third, it is the levels of IL-6, $TNF-{\alpha}$, $IFN-{\gamma}$, $IL-1{\beta}$, IgG, IgM and anti-collagen II in serum and the level of $IFN-{\gamma}$, $IFN-{\gamma}/IL-4$ ratio in CIA mouse spleen cell culture. Fourth, it is histological analysis of the mice joint. Fifth, it is expression ratio of CD3e+ to CD19+ cell, CD4+ to CD8+ cell, CD69+/CD3e+ cells, CD11a+/CD19+ cells and CD11b+/Gr-l+ cells and CD4+/CD25+ cells. Results : 1. In the MR-HA, the incidence of arthritis and the arthritis index were significantly decreased. 2. In MR-HA, the levels of IL-6, $IFN-{\gamma}$, $TNF-{\alpha}$, $IL-1{\beta}$, IgG, IgM and anti-collagen II in serum of CIA mice and the level of $IFN-{\gamma}$, IL-4, $IFN-{\gamma}$, IL-4 ratio in CIA mouse spleen cell culture were significantly decreased. 3. In histology, the cartilage destruction and synovial cell proliferation were decreased in the MR-HA, and the collagen fiber expressions in the MR-HA were similar with that of the Normal group. 4. In the MR-HA, the expression ratio of CD3e+ to CD19+ cell and CD4+ to CD8+ cell were similarly maintained as Normal group in lymph nodes, and CD69+/CD3e+ cells and CD11a+/CD19+ cells were decreased in lymph nodes, and CD11b+/Gr-1+ cells and CD4+/CD25+ cells were decreased in synovium. Conclusion : These results suggest that MR-HA at ST36 has an effect to control synovial cell proliferation and cartilage destruction in rheumatoid arthritis, as well as prophylaxis is important to treat rheumatoid arthritis in clinic.

  • PDF

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Compensatory change of opposite hippocampus after temporal lobe surgery in patients with temporal lobe epilepsy Evidence from single-voxel proton MR spectroscopy

  • Lee, Sang-Hyun;Chang, Kee-Hyun;Chung, Chun-Kee;Song, In-Chan;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.172-172
    • /
    • 2001
  • Purpose: To evaluate compensatory change of opposite hippocampus after temporal lobe surgery in th patient with temporal lobe epilepsy by using single-voxel proton MR spectroscopy. Method: Eighteen patients with intractable temporal lobe epilepsy (TLE) whose MR diagnos was unilateral hippocampal sclerosis (n=11) or localized unilateral anterior temporal lobe lesio (n=7) and who underwent anterior temporal lobectomy were included in the study. Singl proton MRS of opposite hippocampus was carried out on the same day or within 1 week af MR imaging before temporal lobe surgery and after over 1-year post-surgical follow-u Single voxel proton MRS were acquired using GE signa 1.5T scanner and spectrosco system (TR, 1500-2, 000: TE, 136-144). Region of interest (ROI) was placed in a simitar position for all examination to cover the medial temporal lobes including most of the head an body of hippocampus and a part of amygdala, the parahippocampal gyrus. The MR spectr were evaluated with a focus on the metabolite ratio of N-acetylaspartate (NAA choline-containing phospholipids (Cho), creatine (Cr). The metabolite ratios of NAA/ Cr were calculated from the relative peak height measurement. We evaluated change of th intensity ratio NAA/Cr between before and after surgery, to simplify quantification acro patients, because observed decreases in the ratio of NAA/Cr can be interpreted in terms o neuronal or axonal damage.

  • PDF

Dependence of Magnetoresistance on the Underlayer Thickness for Top-type Spin Valve (Top형 스핀밸브 구조의 Si 기판에서의 하지층 두께에 따른 자기저항 특성 연구)

  • Ko, Hoon;Kim, Sang-Yoon;Kim, Soo-In;Lee, Chang-Woo;Kim, Ji-Won;Jo, Soon-Chul
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.95-98
    • /
    • 2007
  • In this paper, the magnetic properties and the annealing behavior of spin valve structures with Mo(MoN) underlayers were studied for various underlayer thickness. The spin valve structure was Si substrate/Mo(MoN)$(t{\AA})/NiFe(21{\AA})/CoFe(28{\AA})/Cu(22{\AA})/CoFe(18{\AA})/IrMn(65{\AA})/Ta(25 {\AA})$. Mo and MoN films were deposited on Si substrates and their thermal annealing behavior was analyzed. The deposition rate of the MoN thin film was decreased and tile resistivity of the MoN thin films were increased as the $N_2$ gas flow was increased. The variations of MR ratio and magnetic exchange coupling field of spin valve structure were smaller with MoN underlayers than that with Mo underlayers up to thickness of $51{\AA}$. MR ratio of spin valves with Mo underlayers was 2.86% at room temperature and increased up to 2.91 % after annealing at $200^{\circ}C$. Upon annealing at $300^{\circ}C$, the MR ratio decreased about 2.16%. The MR ratio of spin valves structure with MoN underlayers for $N_2$ gas flow 1 sccm was 5.27% at room temperature and increased up to 5.56% after annealing at $200^{\circ}C$. Upon annealing at $300^{\circ}C$, the MR ratio decreased about 4.9%.

The Effects of Flexural Strength Ratio on High Strength Beam-Column Joint Subjected to Reversed Cyclic Loads (반복하중을 받는 고강도 철근콘크리트 보-기둥 접합부의 휨강성비에 관한 연구)

  • 이광수;오정근;문정일;권영호;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.63-67
    • /
    • 1990
  • The purpose of this study was to investigate the effects of flexural strength ratio(Mr=$\Sigma$Mc/$\Sigma$Mb) with High-Strength Concrete up to 800Kg/$\textrm{cm}^2$. Five specimens were tested under reversed cyclic loadings. The primary variables were flexural strength ratio of the beam-column, compressive strength of concrete and loading patterns. The results showed that the failure at the beam-column joint in case of high strength concrete was severe more than in case of normal strength concrete when flexural strength ratio 1.4. Thus the part for low limit of flexural strength ratio(Mr=1.4) should be revised for high strengthconcrete.

  • PDF