Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제9권2호
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

Electromagnetic design study of a 7 T 320 mm high-temperature superconducting MRI magnet with multi-width technique incorporated

  • Jang, Won Seok;Kim, Geonyoung;Choi, Kibum;Park, Jeonghwan;Bang, Jeseok;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.30-34
    • /
    • 2021
  • Superconducting magnets have paved the way for opening new horizons in designing an electromagnet of a high field magnetic resonance imaging (MRI) device. In the first phase of the superconducting MRI magnet era, low-temperature superconductor (LTS) has played a key role in constructing the main magnet of an MRI device. The highest magnetic resonance (MR) field of 11.7 T was indeed reached using LTS, which is generated by the well-known Iseult project. However, as the limit of current carrying capacity and mechanical robustness under a high field environment is revealed, it is widely believed that commercial LTS wires would be challenging to manufacture a high field (>10 T) MRI magnet. As a result, high-temperature superconductor together with the conducting cooling approach has been spotlighted as a promising alternative to the conventional LTS. In 2020, the Korean government launched a national project to develop an HTS magnet for a high field MRI magnet as an extent of this interest. We have performed a design study of a 7 T 320 mm winding bore HTS MRI magnet, which may be the ultimate goal of this project. Thus, in this paper, design study results are provided. Electromagnetic design and analysis were performed considering the requirements of central magnetic field and spatial field uniformity.

Left-Sided Cisterna Chyli: a Case Report on a Rare Normal Anatomic Structure

  • Seo, Jin Ho;Hwang, Jeong Ah;Shin, Hyeong Cheol;Kim, Seung Soo;Park, Chan Ho;Lee, Hyoung Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.276-278
    • /
    • 2019
  • The cisterna chyli, a dilated lymphatic sac in the retrocrural space, is usually located to the right of the aorta. We report a case of a left-sided cisterna chyli, which was incidentally detected on the radiologic examinations of a preoperative workup for cholangiocarcinoma. Computed tomography (CT) and magnetic resonance (MR) images revealed a cisterna chyli measuring 2.5 cm in length in the left retrocrural space. The dilated lumbar lymphatics joined with the cisterna chyli, which was continuous with the left-sided thoracic duct. To the best of our knowledge, this is the second antemortem case of a left-sided cisterna chyli in literature. The cisterna chyli can mimic retrocrural lymphadenopathy, solid tumor with cystic degeneration, abscess or hematoma. The left-sided cisterna chyli should be referred to as a structure so as to be cautious in surgical approach.

Color Dispersion as an Indicator of Stellar Population Complexity for Galaxies in Clusters

  • 이준협;박민아;이혜란;오슬희
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.34.1-34.1
    • /
    • 2018
  • We investigate the properties of bright galaxies with various morphological types in Abell 1139 and Abell 2589, using the pixel color-magnitude diagram (pCMD) analysis. The 32 bright member galaxies ($Mr{\leq}-21.3mag$) are deeply imaged in the g and r bands in our CFHT/MegaCam observations, as a part of the KASI-Yonsei Deep Imaging Survey of Clusters (KYDISC). We examine how the features of their pCMDs depend on galaxy morphology and infrared color. We find that the g - r color dispersion as a function of surface brightness (${\mu}r$) shows better performance in distinguishing galaxy morphology, than the mean g - r color does. The best set of parameters for galaxy classification appears to be a combination of the minimum color dispersion at ${\mu}r{\leq}21.2mag\;arcsec-2$ and the maximum color dispersion at $20.0{\leq}{\mu}r{\leq}21.0mag\;arcsec-2$: the latter reflects the complexity of stellar populations at the disk component in a typical spiral galaxy. Moreover, the color dispersion of an elliptical galaxy appears to be correlated with its WISE infrared color ([4.6]-[12]). This indicates that the complexity of stellar populations in an elliptical galaxy is related to its recent star formation activities. From this observational evidence, we infer that gas-rich minor mergers or gas interactions may have usually occurred during the recent growth of massive elliptical galaxies.

  • PDF

Nuclear Medicine Physics: Review of Advanced Technology

  • Oh, Jungsu S.
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.81-98
    • /
    • 2020
  • This review aims to provide a brief, comprehensive overview of advanced technologies of nuclear medicine physics, with a focus on recent developments from both hardware and software perspectives. Developments in image acquisition/reconstruction, especially the time-of-flight and point spread function, have potential advantages in the image signal-to-noise ratio and spatial resolution. Modern detector materials and devices (including lutetium oxyorthosilicate, cadmium zinc tellurium, and silicon photomultiplier) as well as modern nuclear medicine imaging systems (including positron emission tomography [PET]/computerized tomography [CT], whole-body PET, PET/magnetic resonance [MR], and digital PET) enable not only high-quality digital image acquisition, but also subsequent image processing, including image reconstruction and post-reconstruction methods. Moreover, theranostics in nuclear medicine extend the usefulness of nuclear medicine physics far more than quantitative image-based diagnosis, playing a key role in personalized/precision medicine by raising the importance of internal radiation dosimetry in nuclear medicine. Now that deep-learning-based image processing can be incorporated in nuclear medicine image acquisition/processing, the aforementioned fields of nuclear medicine physics face the new era of Industry 4.0. Ongoing technological developments in nuclear medicine physics are leading to enhanced image quality and decreased radiation exposure as well as quantitative and personalized healthcare.

혈액투석 환자에서 발생한 중심 정맥 협착의 혈관성형술 후 호전된 대뇌 정맥 고혈압: 증례 보고 (Resolved Cerebral Venous Hypertension after Angioplasty of Central Venous Stenosis in a Hemodialysis Patient: A Case Report)

  • 강희민;박성태
    • 대한영상의학회지
    • /
    • 제83권1호
    • /
    • pp.206-211
    • /
    • 2022
  • 혈액투석 환자에서 중심정맥 협착은 비교적 흔한 합병증이다. 하지만 중심정맥 협착으로 인해 대뇌 정맥 고혈압과 이로 인한 신경학적 증상이 발생하는 것은 비교적 드물다. 중심정맥협착으로 인해 발생한 좌측 내경정맥으로부터의 역행성 혈류로 대뇌 정맥 고혈압이 발생한 63세 남성의 증례를 보고하고자 한다. 환자는 중심정맥 협착에 대한 치료를 받은 후 증상 및 치료 전 자기공명영상에서 역행성 혈류를 의미하는 time-of-flight 신호가 소실되었다.

영상의학과 의사의 시각에서 본 자기공명영상 기반 전립선 표적 생검 (MR-Guided Targeted Prostate Biopsy from Radiologists' Perspective)

  • 김소연;박계진
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1220-1232
    • /
    • 2023
  • 전립선암의 진단은 전립선을 10-12구역으로 나눠서 무작위로 조직을 얻는 체계적 생검 방식이 표준적으로 사용되어 왔다. 그러나 종괴의 위치나 유무와 상관없이 조직의 획득이 이루어지기 때문에 일부 전립선암을 놓치거나 임상적으로 중요하지 않은 암을 과도하게 발견한다는 점에서 비판을 받고 있다. 이를 보완하기 위해 자기공명영상 기반 전립선 표적 생검이 제안되었으며 이는 자기공명영상에서 의심 병변을 발견 후 이를 토대로 초음파 유도 혹은 MRI 유도하에 표적 생검을 하는 방식이다. 본 종설에서는 자기공명영상 기반 표적 생검의 방식에 대해서 살펴보고 최근 전립선암 진단에 있어서의 가이드라인과 최근 동향에 대해 다루고자 한다.

후두엽의 허혈성 뇌졸중 환자에서 시각피질의 기능적 자기공명영상 (Functional MRI of Visual cortex in the Patients with Occipital Lobe Ischemia)

  • 이영준;정태섭;윤영수;한승한;조영재;배준호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.173-178
    • /
    • 1999
  • 목적 : 후두엽의 허혈성 경색환자에서 시각피질의 기능적 자기공명영상의 유용성을 알아보고자 하였다. 대상 및 방법 : 후대뇌동맥의 시각파절 부위에 대한 혈류공급 장애로 인하여 시각피질의 허혈 또는 경색 증후를 보이는 환자 4명을 대상으로 하였다. 모든 환자는 안과적 시야검사를 받았으며 자기공명 혈관조영술(n=4)과 디지털 감산 혈관조영술(n=2)을 시행하여 혈관이상을 확인하였다. 기능적 자기공명영상은 2D-FLASH 기법(TRITE = 90/56 msec, TA = 8.32 see, $FOV{\;}={\;}240{\times}240,{\;}matrix{\;}No.={\;}64{\times}128$, slice thickness = 8mm)을 이용하였으며 초당 8 회로 점멸하는 적색 광자극원을 이용하여 5회의 광자극기간과 5회의 휴식기간을 번갈아 8차례, 총 40회의 검사를 시행하였다. 기능적 자기공명영상 소견을 안과적 시야검사 결과, 고식적 자기 공명영상 결과, 혈관조영술 결과와 비교 분석하였다. 결과 : 기능적 자기공명영상에서는 모든 환자가 혈관조영술에서 혈관이상을 보인쪽의 시각피질의 활성화가 이루어지지 않는 소견을 보였다. 그러나 이중에 2 환자는 고식적 자기공명영상이 정상이었다. 시야결손이 3 환자에서 관찰되었는데 이중 한 환자는 고식적 자기공명영상과 확산 자기공명영상에셔 정상소견이었지만 기능적 자기공명영상에서는 시야결손이 있는 쪽의 시각피 질의 촬성화가 이루어지지 않는 소견을 보였다. 결론 : 시각피질의 기능적 자기공명영상은 안과적 시야검사, T2강조영상 또는 확산강조명영상에서 발견되지 않는 시각피질의 허혈 또는 혈류잠재능 감소 상태를 감지할 수 있는 민감한 검사 방법이라고 생각된다.효율적이고 강력한 QA 도구로 자리 잡을 수 있을 것으로 기대된다.지하였으며 폐사율은 각각 1.9%, 1.9%, 2.9%와 1.0%로써 대조군의 4.8%에 비하여 낮은 수준을 보여 질병에 대한 저항능력이 향상되었다.kg/h로 분석되었다. 6. 건조작업 중에 소요되는 전력은 9.5~19.3 Wh/kg이었으며, 연료효율 6.9~9.3kg-$H_2$O/L와 열효율 50.2~65.1%에 의한 수분증발량은 124.0~125.4 kg-$H_2$O/h 로 나타났다. 7. 건조기의 열효율을 70%를 기준으로 평가한다면, 시작기의 열효율은 조금 낮은 수준이며, 열관리 계통의 개선을 필요로 하였다. 8. 제작된 계분건조기의 시작기를 15,000수 규모의 양계농장에서 사용한다면 관행의 계분처리 방법에 비하여 약 590,700(원/월)의 비용을 절감할 수 있을 것으로 추정되었다}0.09\;ml/1.5\;hr)$. 이상(以上)의 결과(結果)는 ethanol의 혈중농도(血中濃度)가 높을수록 더 심(甚)한 혈압강하작용(血壓降下作用)을 나타내며, ethanol 로 인(因)한 이뇨작용(利尿作用)도 ethanol 량(量)이 증가(增加)함에 따라 뇨량(尿量)도 증가(增加)함을 보여 주었다.ults showed that the overall quality of Sullungtang significantly decreased as the parity increased for Hanwoo cows. The Sullungtang extracted from bones of heifer had the best sensory scores as well as nutritional quality when compared

  • PDF

국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교 (The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions)

  • 김영철;김명진;차승환;정용은;한광협;최진섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.39-48
    • /
    • 2007
  • 목적 : 다양한 강한 T2 고속 스핀 에코 기법과 균형항정상태세차를 이용한 고속 영상 기법을 이용하여 국소 간병변 진단시 낭성 여부를 평가하고 악성 여부를 진단하는데 4가지 기법간의 유의한 차이가 있는지를 알아보고자 하였다. 대상 및 방법 : 2005년 6월부터 8월까지 76명의 환자에서 자기공영상에서 확인된 93예의 국소 간 병변을 대상으로 하였다. 초전도형 1.5T 자기 공명 영상 장치를 이용 세가지 다른 에코시간(80, 180-190, 300 msec)의 호흡 중지 T2강조 단발 고속 스핀 에코 촬영 기법과 호흡 중지 2차원 균형항정상태세차를 이용한 기법의 고속 영상 기법으로 시행되었다. 2명의 방사선과 전문의가 정성적 분석하였다. 그리고, 또 다른 방사선과 전문의가 병변 대 병변 대간 대조대잡음비를 구하였다. 결과 : 네 가지 기법에서 판독자간의 일치도는 낭성 평가와 악성도 평가에서 통계적으로 유의한 차이는 보이지 않았다. 낭성 그리고 악성도 평가의 정확도는 에코시간 80 msec에서 가장 높았다. 악성도 평가시 제 2 판독자에서 에코시간 80 msec과 균형항정상태세차간에 p-값이 0.004로 통계적으로 유의한 차이를 보였다. 병변 대 간 대조대잡음비를 구하였고 에코시간이 길어질수록 낭성 병변의 대조대잡음비는 증가되는 결과를 보였다. 결론 : 단발 고속 스핀 에코 기법이 정확성과 일치도에서 균형항정상태세차기법보다 우수하였다. 통계적 유의성은 없으나 에코시간 80 msec이 에코시간 300 msec보다 약간 높은 정확도와 일치도를 보였다. 그리고, 에코시간 180 msec의 강한 T2 강조 단발 고속 스핀 에코기법은 에코시간 80 msec에서 판정이 애매할 경우 추가적인 도움이 될 수 있다.시하고자 한다.기성분은 균주에 따른 약간의 차이가 있었으나 경향은 비슷하게 나타났다. 이상의 결과 알코올 발효 균주에 따른 참다래 와인의 이화학적 품질특성에는 큰 차이가 없었으나 고급알코올함량을 비교하였을 때 Sacch. cerevisiae Wine 3이 와인제조에 가장 적합한 것으로 평가되었다.장 낮은 값을 나타내었으며, 홍국의 함유량이 증가할수록 유의적으로 증가하였다. b값은 CSB가 가장 낮은 값을 나타내었으며, 홍국의 함유량이 증가할수록 유의적으로 증가하였다. 물성측정 결과 경도와 응집성은 각 시료들 간의 유의적인 차이가 나타나지 않았다. 탄력성과 부서짐성은 CSB가 가장 낮았으며, 홍국의 함유량이 증가할수록 증가하였다. 점착성은 SDB1이 가장 낮았으며, 홍국의 함유량이 증가할수록 증가하였다. 관능검사 결과 기공의 균일성은 SDB1이 가장 균일한 것으로 나타났으며, 색은 홍국의 함유량이 증가할수록 높게 나타났다. 경도, 탄력성, 단맛 및 신맛 등은 홍국 함유량이 증가할수록 증가하는 것으로 나타났다. 이취는 SDB1이 가장 적게 나는 것으로 나타났으며, 전반적인 기호도는 SDB1이 가장 높았다. 따라서 홍국을 10% 첨가한 sourdough starter를 3일 동안 발효한 후 반죽에 첨가하여 sourdough bread를 제조할 때 품질이 가장 우수한 제품을 얻을 수 있었다.생수와 여러 물질의 혼합용액의 온도가 장에 끼치는 자극에 차이가 있지 않나 추측되며 이에 관한 추후 연구가 요망된다. 총대장통과시간의 단축은 결장 분절 모두에서 줄어들어 나타났으나 좌측결장 통과시간의 감소 및 이로 인한 이 부위의 통과시간 비율의 저하가 가장 주요하였다. 이러한 결과는 차가운 생수 섭취가 주로 결장 근위부를 자극하는

  • PDF

내측반월상 연골의 가성방사파열: 비교적 흔한 진단상 함정 (Pseudoradial Tear of the Medial Meniscus: A Relatively Common Potential Pitfall)

  • 유우영;최정아;오경진;민선정;최재정;장석기;황대현;강익원
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권3호
    • /
    • pp.219-224
    • /
    • 2014
  • 목적: 무릎관절 자기공명영상에서 내측 반월상연골 전각의 끝이 잘린 삼각형 모습 (truncated triangle appearance)의 빈도와 그 임상적 가치에 대하여 알아보고자 하였다. 대상과 방법: 위 연구는 기관윤리심의위원회 (IRB)의 승인을 받았으며, 사전동의를 받아 진행하였다. 가성방사파열로 판단하는 기준은 내측 반월상연골 전각부터 중심부에서 끝이 잘린 삼각형 모습과 뭉툭해진 끝 주변에 물과 같은 신호강도가 한 개 또는 그 이상의 관상면 영상에서 보일 경우로 하였다. 두 명의 근골격계를 전공한 영상의학과 의사가 후향적으로 485개의 무릎관절 자기공명영상을 독립적으로 내측 반월상연골의 가성방사파열의 유무와 위 소견이 보이는 영상의 개수를 자기공명영상의 양자밀도강조 관상영상을 이용하여 평가하였다. 관찰자간 일치도와 관찰자내 일치도는 카파 계수로 평가되었고, 관절경 소견과 연관시키기 위하여 의무기록을 참조하였다. 결과: 내측 반월상연골의 가성방사파열은 381명 (78.6%)의 환자에서 관찰되었다. 병변의 위치는 내측 반월상연골의 전각에 112명 (29.4%), 전각부터 중심부에 143명 (37.5%), 중심부에 126명 (33.1%)에서 각각 나타났다. 가성방사파열의 소견이 보이는 연속적인 단면 영상의 개수는 100명 (26.2%)에서 1개, 164명 (43.0%)에서 2개, 94명 (24.7%)에서 3개, 21명 (5.5%)에서 4개, 2명 (0.5%)에서 5개로 각각 나타났다. 관찰자간 일치도는 병변의 유무에 대해서는 0.99, 가성방사파열의 소견이 보이는 단면영상의 개수에 대해서는 0.43로 각각 나타났다. 관절경은 96명의 환자에서 시행되었고, 관절경상에서 모든 내측 반월상연골은 정상소견을 보였다. 결론: 무릎 자기공명 관상면 영상에서 내측 반월상연골의 전각과 중심부의 가성방사파열은 흔히 보이는 소견으로써 실제 방사파열과 감별이 필요한 영상의학과 의사가 알고 있어야 할 진단상 함정으로 사료된다.