• Title/Summary/Keyword: MR images

Search Result 804, Processing Time 0.025 seconds

The fate of necrosis-avid MR contrast material (Gadophrin-2)-enhanced area of acute reperfused myocardial infarction as determined by MR imaging with Gd-DTPA enhancement and TTC staining after four weeks in a rabbit model

  • Choe, Yeon-Hyeon;Park, Jong-Min;Weinmann, Hanns J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.114-114
    • /
    • 2002
  • Purpose: To know the fate of Gadophrin-2-enhanced areas in hearts with acute reperfused myocardial infarction. Method: The left anterior descending branches of coronary arteries were occluded for 90 min and reperfused for 60 min in 15 rabbits. Then, Gadophrin-2 (0.05 mmol/kg) was injected via ear veins. Short-axial T1-weighted spin echo images and fast cine images were obtained 24 hours after injection of Gadophrin-2. After four weeks, short-axial cine MRI was performed and T1-weighted spin echo Images were obtained 5 min and 15 min after injection of Gd-DTPA (0.2 mmol/kg). The animals were sacrificed and short-axial slices of the specimen were stained with 1.5% triphenyltetrazolium chloride (TTC) solution.

  • PDF

Supratentorial Gangliocytoma Mimicking Extra-axial Tumor: A Report of Two Cases

  • Ho Sung Kim;Ho Kyu Lee;Ae Kyung Jeong;Ji Hoon Shin;Choong Gon Choi;Shin Kwang Khang
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.108-112
    • /
    • 2001
  • We report two cases of supratentorial gangliocytomas mimicking an extra-axial tumor. MR imaging indicated that the tumors were extra-axial, and meningiomas were thus initially diagnosed. Relative to gray matter, the tumors were hypointense on T1-weighted images and hyperintense on T2-weighted images. On contrast-enhanced T1-weighted images, homogeneous enhancement was observed, while CT scanning revealed calcification in one of the two cases.

  • PDF

MR Imaging of Shaken Baby Syndrome Manifested as Chronic Subdural Hematoma

  • Yul Lee;Kwan Seop Lee;Dae Hyun Hwang;In Jae Lee;Hyun Beom Kim;Jae Young Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.171-174
    • /
    • 2001
  • Shaken baby syndrome (SBS) is a form of child abuse that can cause significant head injuries, of which subdural hematoma (SDH) is the most common manifestation. We report the MRI findings of chronic SDH in three cases of SBS, involving two-, three- and eight-month-old babies. The SDH signal was mostly low on T1-weighted images and high on T2-weighted images, suggesting chronic SDH. In chronic SDH, a focal high signal on T1-weighted images was also noted, suggesting rebleeding. Contrast-enhanced MRI revealed diffuse dural enhancement.

  • PDF

Analysis and Comparison of MR Signal Strength and SNR Value for Optimal FOV (최적의 FOV를 위한 MR신호강도와 신호 대 잡음비 값의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.109-113
    • /
    • 2018
  • Despite the continuous development of software, it is continuously pursued to enlarge the examination area of FOV in order to reduce the factors of inconsistency in images that appear in continuous examination during wide area examination using contrast agent such as whole body angiography. In this study, we investigated the optimal FOV by comparing the SNR values according to the changes of FOV. The change of the FOV was gradually changed to $270{\times}200$, $300{\times}223$, $330{\times}244$, $360{\times}266$ and $380{\times}281$. SE images at TR 450 msec and TE 10 msec, FSE images at TR 2,000 msec, TE 80 msec, and GE images were scanned at TR 117 msec, and TE 16 msec. SNR values were calculated from the mean values of signal intensities of five phantom images and the signal intensity values of four background standard deviations. As a result of the study, the signal intensity and the SNR value according to the change of the FOV value gradually increased as the FOV was increased, but it was found that the SNR value decreased at a constant size. In conclusion, the results are different from previous studies that the SNR increases as the FOV increases. The cause of these results could not be confirmed. However methods that can be imaged and included within the effective FOV should be considered.

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF

3D Rendering of Magnetic Resonance Images using Visualization Toolkit and Microsoft.NET Framework

  • Madusanka, Nuwan;Zaben, Naim Al;Shidaifat, Alaaddin Al;Choi, Heung-Kook
    • Journal of Multimedia Information System
    • /
    • v.2 no.2
    • /
    • pp.207-214
    • /
    • 2015
  • In this paper, we proposed new software for 3D rendering of MR images in the medical domain using C# wrapper of Visualization Toolkit (VTK) and Microsoft .NET framework. Our objective in developing this software was to provide medical image segmentation, 3D rendering and visualization of hippocampus for diagnosis of Alzheimer disease patients using DICOM Images. Such three dimensional visualization can play an important role in the diagnosis of Alzheimer disease. Segmented images can be used to reconstruct the 3D volume of the hippocampus, and it can be used for the feature extraction, measure the surface area and volume of hippocampus to assist the diagnosis process. This software has been designed with interactive user interfaces and graphic kernels based on Microsoft.NET framework to get benefited from C# programming techniques, in particular to design pattern and rapid application development nature, a preliminary interactive window is functioning by invoking C#, and the kernel of VTK is simultaneously embedded in to the window, where the graphics resources are then allocated. Representation of visualization is through an interactive window so that the data could be rendered according to user's preference.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Morphologic Changes of L5 Root at Coronal Source Images of MR Myelography in Cases of Foraminal or Extraforaminal Compression

  • Kim, Soo-Beom;Jang, Jee-Soo;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • Objective: Two findings easily found at coronal source images of MR myelography (MRM) were evaluated : dorsal root ganglion (DRG) swelling and running course abnormality (RCA) of L5 exiting root at foramen or extraforamen. We tried to find the sensitivity of each finding when root was compressed. Methods: From 2004 July to 2006, one hundred and ten patients underwent one side paraspinal decompression for their L5 root foraminal or extraforaminal compression at L5-S1 level. All kinds of conservative treatments failed to improve leg symptom for several months. Before surgery, MRI, CT and MRM were done. Retrospective radiologic analysis for their preoperative MRM coronal source images was done to specify root compression sites and L5 root morphologic changes. Results: DRG swelling was found in 66 (60%) of 110 patients. DRG swelling has statistically valuable meaning in foraminal root compression (chi-square test, p<0.0001). Seventy-two (66%) in 110 patients showed abnormal alteration of running course. Abnormal running course has statistically valuable meaning in foraminal or extraforaminal root compression (chi-square test, p<0.0001). Conclusion: Three-dimensional MRM provides precise thin sliced coronal images which are most close to real operative views. DRG swelling and running course abnormality of L5 exiting root are two useful findings in diagnosing L5 root compression at L5-S1 foramen or extraforamen. MRM is thought to provide additional diagnostic accuracy expecially in L5-S1 foraminal and extraforaminal area.

Comparison of the capsular width measured on ultrasonogrape and MR image of the temporomandibular joint (측두하악관절의 초음파영상과 자기공명영상에서 하악과두 외측면과 관절낭간 거리 측정치 비교)

  • Lee Tae-Wan;Yoo Dong-Soo;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • Purpose : To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint (TMJ). Materials and Methods : Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonographs of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonograph of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonographs was compared, according to mouth position and disc postion. Results : The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position were 0.92 and 0.81. The measurement error was 0.4% and 0.7%. At the TMJ with normal disc position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonographs were $2.0{\pm}0.7mm,\;1.8{\pm}0.5mm$, respectively (p<0.05). On the ultrasonographs, the distances at open mouth position were $1.2{\pm}0.5mm$ (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were $1.3{\pm}0.3\;mm\;and\;0.9{\pm}0.2\;mm$ (p<0.05). Conclusion : The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  • PDF