• 제목/요약/키워드: MR angiography

검색결과 154건 처리시간 0.021초

Diagnostic Criteria of T1-Weighted Imaging for Detecting Intraplaque Hemorrhage of Vertebrobasilar Artery Based on Simultaneous Non-Contrast Angiography and Intraplaque Hemorrhage Imaging

  • Lim, Sukjoon;Kim, Nam Hyeok;Kwak, Hyo Sung;Hwang, Seung Bae;Chung, Gyung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.323-331
    • /
    • 2021
  • Purpose: To investigate the diagnostic criteria of T1-weighted imaging (T1W) and time-of-flight (TOF) imaging for detecting intraplaque hemorrhage (IPH) of a vertebrobasilar artery (VBA) compared with simultaneous non-contrast angiography and intraplaque hemorrhage (SNAP) imaging. Materials and Methods: Eighty-seven patients with VBA atherosclerosis who underwent high resolution MR imaging for evaluation of VBA plaque were reviewed. The presence and location of VBA plaque and IPH on SNAP were determined. The signal intensity (SI) of the VBA plaque on T1W and TOF imaging was manually measured and the SI ratio against adjacent muscles was calculated. The receiver-operating characteristic (ROC) curve was used to compare the diagnostic accuracy for detecting VBA IPH. Results: Of 87 patients, 67 had IPH and 20 had no IPH on SNAP. The SI ratio between VBA IPH and temporalis muscle on T1W was significantly higher than that in the no-IPH group (235.9 ± 16.8 vs. 120.0 ± 5.1, P < 0.001). The SI ratio between IPH and temporalis muscle on TOF was also significantly higher than that in the no-IPH group (236.8 ± 13.3 vs. 112.8 ± 7.4, P < 0.001). Diagnostic efficacies of SI ratios on TOF and TIW were excellent (AUC: 0.976 on TOF and 0.964 on T1W; cutoff value: 136.7% for TOF imaging and 135.1% for T1W imaging). Conclusion: Compared with SNAP, cutoff levels of the SI ratio between VBA plaque and temporalis muscle on T1W and TOF imaging for detecting IPH were approximately 1.35 times.

새로운 건강보험 보장성 강화 대책 1부: 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여 확대 (A New Healthcare Policy in Korea Part 1: Expanded Reimbursement Coverage of Brain MRI, Brain/Neck MRA, and Head and Neck MRI by National Health Insurance)

  • 김은희
    • 대한영상의학회지
    • /
    • 제81권5호
    • /
    • pp.1053-1068
    • /
    • 2020
  • 문재인 정부의 새로운 건강보험 보장성 강화 대책에 따라 2018년부터 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI 급여가 확대되어 시행 중이다. 2018년 10월부터 2020년 4월까지 개정되어 현재 시행 중인 MRI 급여와 관련된 '요양급여의 적용기준 및 방법에 관한 세부사항'을 중심으로 정리해 보았다. 이 종설은 MRI 요양급여체계, 두통, 어지럼증 환자의 급여기준조정, 뇌 MRI, 뇌혈관/경부혈관 MRA, 두경부 MRI의 급여기준, 표준영상, 판독소견서 등을 포함하였다. 이 글을 통해 영상의학과 전문의가 보험 영역에서도 전문적인 지식을 갖추어 영상의학과 전문의의 전문성을 확보하고, 소속병원에서 주도적인 역할을 하는데 도움이 되고자 한다. MRI 급여화 확대 정책이 진행 중으로 관련 보건복지부의 세부고시가 개정될 수 있다. 따라서 MRI와 보험과 관련된 사안을 지속적으로 업데이트하는 것이 요망된다.

조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교 (Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods)

  • 장민지;최현석;정소령;안국진;김범수
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.152-158
    • /
    • 2012
  • 목적: 뇌내 정맥혈관을 평가하기 위한 조영 증강 자기공명 정맥촬영술의 arterial trigger 와 venous trigger 방법으로 시행한 영상의 차이점을 비교 분석하고자 한다. 대상과 방법: 건강검진을 목적으로 자기공명정맥촬영술을 시행한 41명의 환자들을 대상으로 해면부위의 내경 동맥에서 arterial triggering하여 6초 후에 얻은 영상 (n = 20) 과 상시상 정맥동에서 venous triggering (n = 21) 방법으로 시행한 영상을 후향적으로 분석하였다. 영상은 가돌리늄 조영제 ($Magnevist^{(R)}$, Schering, Germany)를 0.1 mmol/kg 정맥주입하여 시행하였고, 두개강 전반에 대하여 시상영상을 fast spoiled gradiend echo sequence로 시행하였다 (TR/TE 5.2/1.5, matrix $310{\times}310$, 절편수 124 절편, 두께 15 cm). 두 그룹의 영상을 해부학적 정맥 혈관 구조에 따라 17 정맥구역에 대하여 평가하였고, 정맥의 영상품질은 세 단계 (안보임, 일부 보임, 완전히 보임)로 나눠서 평가하였다. 결과: 정맥이 완전히 보인 구역은 arterial triggering 자기공명 정맥 촬영술에서 84% (272/323), venous triggering 자기 공명 정맥촬영술에서 91% (310/340) 이다. Venous triggering 자기공명촬영술과 arterial 자기 공명 정맥촬영술을 비교하였을 때 뇌내 정맥 구조를 평가하는데 있어 venous triggering 방법이 통계적으로 유의하게 높았다 (Fisher exact test, p<0.006). 결론: 조영 증강 자기공명 정맥 촬영술은 정맥 혈관 구조에 대한 고화질의 이미지를 제공하였고 arterial triggering 방법보다 venous triggering 방법이 뇌내 정맥 구조 평가에 우월한 것으로 나타났다.

뇌경막 정맥동 혈전증 - 증례보고 - (Cerebral Dural Sinus Thrombosis - Case Report -)

  • 한영민;이종필;황형식;임대철;송준호;안명수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권3호
    • /
    • pp.389-394
    • /
    • 2001
  • 경막정맥동 혈전증은 다양한 원인을 가진 비교적 드문 질환으로 알려져왔으며 임상양상 및 발현형태가 매우 다양하여 임상적 진단이 쉽지 않았다. 그러나 최근에는 여러 영상진단 방법, 특히 자기공명영상 혈관 촬영등을 통해 조기 진단이 가능하게되었다. 치료 방법을 결정할 때, 환자의 임상증상과 정맥순환계의 개인간 차이가 매우 중요한 인자중 하나이다. 저자들은 보존적 치료로 좋은 결과를 얻은 2례의 경막정맥동 환자의 특성을 문헌고찰과 함께 보고하는 바이다.

  • PDF

종격동에 발생한 림프혈관종 -1예 보고- (Lymphangiohemangioma of the Mediastinum -A case report-)

  • 송승환;이충원;김영규;이창훈;이민기;정연주;김영대
    • Journal of Chest Surgery
    • /
    • 제39권5호
    • /
    • pp.423-425
    • /
    • 2006
  • 종격동에 발생한 림프혈관종은 아주 드문 질환으로 수술 전 컴퓨터 단층촬영과 자기공명 혈관촬영상 흉선 기원 종양으로 오인된 환자의 수술 소견상 무명정맥에서 기인하는 혈관조직의 증식을 보였다. 병리검사상 림프조직과 혈관조직을 모두를 보여 림프혈관종으로 진단하였다.

Inflammatory Pseudotumor in the Lateral Ventricle with Repeated Bleeding-Case Report-

  • Park, Jong-Hwa;Nam, Taek-Kyun;Hwang, Sung-Nam;Park, Seung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권2호
    • /
    • pp.99-102
    • /
    • 2009
  • Inflammatory pseudotumor is an uncommon lesion with unknown etiology characterized by sclerosing inflammation which clinically and radiographically mimics a neoplastic lesion. A 47-year-old man presented with sudden headache and dysarthria. Brain CT scan revealed a $2.6{\times}2.2\;cm$ sized, round, and hyperdense mass in the anterolateral wall of the left lateral ventricular trigone. On MR imaging studies, the mass showed low signal intensity in the wall of the trigone on T2-weighted image, central mixed (iso- and high-) signal intensity with peripheral low-signal intensity on T1-weighted image. Subtle staining of left choroid plexus with irregular shaped distal branch of anterior choroidal artery was found on the cerebral angiography. These findings suggested a small tumorous lesion originated from the left choroid plexus. During the hospital days, the mass manifested as repeated hemorrhages. The mass was successfully removed via left occipital transcortical approach. The histopathological report of the specimen was hemorrhage and fibrosis, with dense lymphoplasma cell infiltration, suggestive of an inflammatory pseudotumor.

Cervical Contrast-Enhanced MRA Using Whole Body Coil at 3.0T: Initial Clinical Experience

  • 권정화;손철호;김홍;우성구;서수지
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.89-89
    • /
    • 2002
  • Purpose: To report initial experience and evaluate feasibility of cervical carotid artery contrast-enhanced MR angiography (CEMRA) using whole body coil at 3.0T Method: Twenty-eight patients (14 male, ages 41-80, mean age 63) underwent CEMRA at the 3.0T using whole body coil and 3D-FSPGR (TR/TE 6.6/l.3 msec, FA 30, thickness 1.3mm), and thirty patients (17 male, ages 30-80, mean age 57) underwent CEMRA at the 1.5T using Helmholtz neck coil and 3D FLASH sequence (TR/TE 3.8/l.4msec, FA 35, thickness 1mm). At both 1.5 and 3.0T, a power injector (Spectris) injected 20m1 of gadolinium to the right or left antecubital vein at a rate of 3mL/s. All CEMRA cases were accepted by one neuroradiologiest. We measured the signal intensities at the bifurcation of common carotid artery (CCA), vertebral artery (V2) and two surrounding tissues (ST) and noise at the background in all patients, and also compared contras-to-noise ratios (CNR) of CCA/ST and V2/ST at 3.0 and 1.5T

  • PDF

후두엽의 허혈성 뇌졸중 환자에서 시각피질의 기능적 자기공명영상 (Functional MRI of Visual cortex in the Patients with Occipital Lobe Ischemia)

  • 이영준;정태섭;윤영수;한승한;조영재;배준호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.173-178
    • /
    • 1999
  • 목적 : 후두엽의 허혈성 경색환자에서 시각피질의 기능적 자기공명영상의 유용성을 알아보고자 하였다. 대상 및 방법 : 후대뇌동맥의 시각파절 부위에 대한 혈류공급 장애로 인하여 시각피질의 허혈 또는 경색 증후를 보이는 환자 4명을 대상으로 하였다. 모든 환자는 안과적 시야검사를 받았으며 자기공명 혈관조영술(n=4)과 디지털 감산 혈관조영술(n=2)을 시행하여 혈관이상을 확인하였다. 기능적 자기공명영상은 2D-FLASH 기법(TRITE = 90/56 msec, TA = 8.32 see, $FOV{\;}={\;}240{\times}240,{\;}matrix{\;}No.={\;}64{\times}128$, slice thickness = 8mm)을 이용하였으며 초당 8 회로 점멸하는 적색 광자극원을 이용하여 5회의 광자극기간과 5회의 휴식기간을 번갈아 8차례, 총 40회의 검사를 시행하였다. 기능적 자기공명영상 소견을 안과적 시야검사 결과, 고식적 자기 공명영상 결과, 혈관조영술 결과와 비교 분석하였다. 결과 : 기능적 자기공명영상에서는 모든 환자가 혈관조영술에서 혈관이상을 보인쪽의 시각피질의 활성화가 이루어지지 않는 소견을 보였다. 그러나 이중에 2 환자는 고식적 자기공명영상이 정상이었다. 시야결손이 3 환자에서 관찰되었는데 이중 한 환자는 고식적 자기공명영상과 확산 자기공명영상에셔 정상소견이었지만 기능적 자기공명영상에서는 시야결손이 있는 쪽의 시각피 질의 촬성화가 이루어지지 않는 소견을 보였다. 결론 : 시각피질의 기능적 자기공명영상은 안과적 시야검사, T2강조영상 또는 확산강조명영상에서 발견되지 않는 시각피질의 허혈 또는 혈류잠재능 감소 상태를 감지할 수 있는 민감한 검사 방법이라고 생각된다.효율적이고 강력한 QA 도구로 자리 잡을 수 있을 것으로 기대된다.지하였으며 폐사율은 각각 1.9%, 1.9%, 2.9%와 1.0%로써 대조군의 4.8%에 비하여 낮은 수준을 보여 질병에 대한 저항능력이 향상되었다.kg/h로 분석되었다. 6. 건조작업 중에 소요되는 전력은 9.5~19.3 Wh/kg이었으며, 연료효율 6.9~9.3kg-$H_2$O/L와 열효율 50.2~65.1%에 의한 수분증발량은 124.0~125.4 kg-$H_2$O/h 로 나타났다. 7. 건조기의 열효율을 70%를 기준으로 평가한다면, 시작기의 열효율은 조금 낮은 수준이며, 열관리 계통의 개선을 필요로 하였다. 8. 제작된 계분건조기의 시작기를 15,000수 규모의 양계농장에서 사용한다면 관행의 계분처리 방법에 비하여 약 590,700(원/월)의 비용을 절감할 수 있을 것으로 추정되었다}0.09\;ml/1.5\;hr)$. 이상(以上)의 결과(結果)는 ethanol의 혈중농도(血中濃度)가 높을수록 더 심(甚)한 혈압강하작용(血壓降下作用)을 나타내며, ethanol 로 인(因)한 이뇨작용(利尿作用)도 ethanol 량(量)이 증가(增加)함에 따라 뇨량(尿量)도 증가(增加)함을 보여 주었다.ults showed that the overall quality of Sullungtang significantly decreased as the parity increased for Hanwoo cows. The Sullungtang extracted from bones of heifer had the best sensory scores as well as nutritional quality when compared

  • PDF

유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구 (A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.201-208
    • /
    • 2018
  • 본 연구는 Image J 프로그램을 사용하여 유속증가 자기공명영상기법의 숙임각 변화에 따른 SNR와 CNR을 측정하여 최적의 숙임각을 알아보기 위해 연구하였다. 총 30명의 정상인 지원자를 대상으로 1.5T 자기공명영상기기(Philips, Medical System, Achieva)를 이용하여 뇌동맥검사 후 평가를 실시하였다. 분석 방법으로 유속증가 자기공명 혈관 조영술에 대하여 4 부위에 관심영역을 설정하고 SNR와 CNR을 평가하였다. 5가지 숙임각에서의 정량적 분석으로 SNR과 CNR에 대한 통계적 유의성은 일원분산분석으로 계산되었으며, 사후 분석으로는 Bonferroni 법을 적용하였고, 통계에 사용된 프로그램은 SPSS 14.0을 이용하여 p 값을 0.05 이하일 때 유의성을 두었다. 본 실험에 대한 결과로서 전교통동맥(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), 후교통동맥 (SNR: $863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR: $1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$), 중대뇌동맥(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$)의 값으로 $25^{\circ}$에서 가장 높은 신호강도를 보였다(p<0.05). 작은 혈관 묘출로서 a1, a2, a3, p1, p2, p3, m1, m2, m3 값 또한 동일한 결과 이었다(p<0.05). 사후분석결과로, 숙임각에서 $25^{\circ}$ 기준으로 $10^{\circ}$, $15^{\circ}$, $20^{\circ}$에서 유의성 있는 결과를 얻었지만(p=0.000) $30^{\circ}$에서는 유의한 차이가 없었다(p>0.05). 결론적으로, 본 연구에서 $30^{\circ}$에서는 신호강도가 떨어지기 때문에 뇌혈관 자기공명조영술에서 최적의 숙임각은 $25^{\circ}$로 나타냈다.

체적 지향형 호흡정지 자기공명 조영술의 가속화에 대한 32채널 코일 어레이의 효용성 (Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA)

  • 이현열;서진석;박재석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.137-145
    • /
    • 2009
  • 목적: 각각 12개와 32개 요소 표면 코일 어레이를 사용한 가속율이 매우 큰 관상동맥 자기 공명 혈관조영술을 병렬 영상 기법에 적용하고 결과를 비교한다. 방법: 5명의 건강한 지원자에 대하여 1.5T 전신 자기공명영상장치에서 각각 12개와 32개 요소 표면 코일 어레이를 사용한 steady state free precession 자기공명 혈관조영술이 수행되었다. 각 지원자의 좌전하방관상동맥과 우관상동맥을 영상하여 데이터를 얻었다. 데이터는 병렬 영상을 위하여 1에서 6에 이르는 감소율로 부분 추출되었다. 양 코일 어레이 각각에 대하여 지형 인자의 평균, 극대, 그리고 인공물정도가 계산되었다. 결과: 모든 감소율에 있어서, 32개 요소 어레이가 12개 요소 어레이에 비하여 지형인자의 평균과 극대, 그리고 인공물정도가 상당히 줄어들었다 (P << 0.1). 지형인자의 평균은 관상동맥의 영상 방향에 민감한 반면, 지형인자 극대치와 인공물정도는 영상 방향에 독립적이었다. 결론: 가속율이 매우 큰 관상동맥 자기공명 혈관조영술의 병렬 영상 적용에 있어 32개 요소 표면 코일 어레이를 사용함은 인공물과 잡음을 상당히 억제시킨다. 32개 요소 표면 코일 어레이를 사용하여 가속율을 증가시키는 것은 공간 해상도를 향상시키거나 3D관상동맥 자기공명 혈관조영술에 있어서 체적 범위를 증가시킬 수 있는 가능성을 제공한다.

  • PDF