• Title/Summary/Keyword: MR Valve

Search Result 135, Processing Time 0.026 seconds

Optimal Design of MR Damper : Analytical Method and Finite Element Method (MR 댐퍼의 최적설계 : 이론적 방법 및 유한요소 방법)

  • Ha, Sung-Hoon;Seong, Min-Sang;Heung, Quoc-Nguyen;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.581-586
    • /
    • 2009
  • This paper presents an optimal design of magnetorheological(MR) damper based on analytical methodology and finite element analysis. The proposed MR damper consists of MR valve and gas chamber. The MR valve is constrained in a specific volume and the optimization problem identifies geometric dimensions of the valve structure that maximize the pressure drop of the MR valve or damping force of the MR damper. In this work, the single-coil annular MR valve structure is considered. After describing the schematic configuration and operating principle of MR valve and damper, a quasi-static model is derived based on Bingham model of MR fluid. The magnetic circuit of the valve and damper is then analyzed by applying the Kirchoff’s law and magnetic flux conservation rule. Based on the quasi-static modeling and the magnetic circuit analysis, the optimization problem of the MR valve and damper is built. The optimal solution of the optimization problem of the MR valve structure constrained in a specific volume is then obtained and compared with the solution obtained from finite element method.

  • PDF

Optimal Design of MR Damper : Analytical Method and Finite Element Method (MR 댐퍼의 최적설계 : 이론적 방법 및 유한요소 방법)

  • Ha, Sung-Hoon;Seong, Min-Sang;Heung, Quoc-Nguyen;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1110-1118
    • /
    • 2009
  • This paper presents an optimal design of magnetorheological(MR) damper based on analytical methodology and finite element analysis. The proposed MR damper consists of MR valve and gas chamber. The MR valve is constrained in a specific volume and the optimization problem identifies geometric dimensions of the valve structure that maximize the pressure drop of the MR valve or damping force of the MR damper. In this work, the single-coil annular MR valve structure is considered. After describing the schematic configuration and operating principle of MR valve and damper, a quasi-static model is derived based on Bingham model of MR fluid. The magnetic circuit of the valve and damper is then analyzed by applying the Kirchoff' s law and magnetic flux conservation rule. Based on the quasi-static modeling and the magnetic circuit analysis, the optimization problem of the MR valve and damper is built. The optimal solution of the optimization problem of the MR valve structure constrained in a specific volume is then obtained and compared with the solution obtained from finite element method.

Electromagnetic Design and Performance Evaluation of an MR valve (MR 밸브의 전자기적 설계와 성능 평가)

  • Kim, Ki-Han;Nam, Yun-Joo;Park, Myeong-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.968-973
    • /
    • 2007
  • This paper presents an electromagnetic design for the magneto-rheological fluid valve. The MR valve can control high-level fluid power without moving parts, due to the apparent viscosity controllability of the MR fluid in magnetic fields. In order to improve the static characteristic of the MR valve, the length of the flux path is decreased by removing the unnecessary bulk of the yoke. Then, in order to improve the dynamic and hysteretic characteristics, the magnetic reluctance of the ferromagnetic material is increased by minimizing the cross sectional area through which the flux passes. Two MR valves, one is a conventional type valve and the other is the proposed one, were fabricated and performance evaluation is experimentally achieved through the comparison study using by-pass damper system.

  • PDF

Modeling of Military Vehicle Suspension System Featuring Disc Spring and MR Valve (접시 스프링과 MR Valve를 적용한 군용차량 현수장치의 모델링)

  • Ha, Sung-Hoon;Choi, Seung-Bok;Rhee, Eun-Jun;Kang, Pil-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.10
    • /
    • pp.979-986
    • /
    • 2009
  • This paper presents a dynamic modeling of a military vehicle suspension featuring disc spring and MR valve. Firstly, the dynamic model of the disc spring is established with respect to the load and pressure. The nonlinear behavior of the spring is incorporated with the model. Secondly, the dynamic model of the MR valve is derived by considering the pressure drop due to the viscosity and yield stress of MR fluid. The governing characteristics of the proposed suspension system are then investigated by presenting the field-dependent pressure drop of the MR valve and spring force of the gas spring.

Electromagnetic Design and Performance Evaluation of an MR Valve (MR 밸브의 전자기적 설계와 성능평가)

  • Kim, Ki-Han;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.240-249
    • /
    • 2008
  • This paper presents an electromagnetic design method for magneto-rheological (MR) valves. Since the apparent viscosity of MR fluids is adjusted by applying magnetic fields, the MR valves can control high-level fluid power without any mechanical moving parts. In order to improve the performances of the MR valve, it is important that the magnetic field is effectively supplied to the MR fluid. For the purpose, the magnetic circuit composed with the yoke for forming magnetic flux path, the electromagnetic coil and the MR fluid should be well designed. In order to improve the static characteristic of the MR valve, the length of the magnetic flux path is decreased by removing the unnecessary bulk of the yoke. Also, in order to improve its dynamic and hysteretic characteristics, the magnetic reluctance of the magnetic circuit should be increased by minimizing the cross-sectional area of the yoke through which the magnetic flux passes. After two MR valves, one is a conventional type valve and the other is the proposed one, are designed and fabricated, their performances are evaluated experimentally.

Development of Flow Control Valve Using MR Fluid (MR유체를 이용한 유량제어 밸브)

  • Lee, Hyung-Don;Bae, Hyung-Sub;Lee, Yuk-Hyung;Park, Myeong-Kwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.888-891
    • /
    • 2011
  • This paper presents development of flow control valve using MR fluid. Generally, since the apparent viscosity of MR fluids is adjusted by applying magnetic fields, the MR valves can control high level fluid power without any mechanical moving parts. In this paper, flow control valve using MR fluid on the behavior of the magnetic field influence on the numerical analysis of more accurate electromagnetic parameters were obtained, even if when magnetic field apply inside of surrounding MR fluid from electromagnet, more realistic designing way analysis of characteristic of whole magnetic field distribution is suggested by surrounding magnetic material. Also, comparison of flow rate inlet and outlet, behavior of MR fluid in experiments proposed. A new type of flow control valve using MR fluid is proposed by analysis of behavior of MR fluid in experiments.

Mitral Valve Reconstruction; Result of Operation Using Prosthetic Ring (승모판막 재건술;인공판륜[prosthetic ring]을 이용한 수술례)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.191-195
    • /
    • 1993
  • Among 25 consecutive cases having undergone mitral valve surgery between March 1991 and June 1992 in Gill General Hospital, 11 patients[44%] who had undergone mitral valve reconstruction using prosthetic rings is evaluated and presented. Patients` mean age is 43 + 19 years[range:16-72], and they are consisted with 4 males and 7 females. Mitral valve insufficiency is due to degenerative disease in 6 cases[55%] and rheumatic disease in 5 patients[45%]. Carpentier`s functional classification I is 2 cases, II is 6 cases, and III is 2 cases. Surgical techniques include prosthetic ring annuloplasty[11 patients, 100%], chorda shortening[6, 55%], leaflet mobilization[4,36%], new chorda formation[2, 18%], chorda transposition[1, 9%] commissurotomy[3, 27%], and papillary muscle splitting[3, 27%]. Average number of mitral anatomic lesions per patient are 2.7 and we used average 2.8 procedures upon mitral valve apparatus per patient. There were no surgical mortality and no late valve related admission during the mean follow up period of 17 months. The mean functional class[NYHA] is 2.81 preoperatively and improved to 1.10 postoperatively. Doppler echocardiography showed much improvement from grade II MR [1 case], grade III MR [1 case] and 9 cases of grade IV MR to 6 cases of patients showed no MR, only trace MR in 4 cases, and grade I MR was found only in one patient with NYHA functional class II postoperatively. The postoperative mean mitral valve area is $2.10+0.28cm^2$. We conclude that mitral reconstruction is a predictable and stable operation.

  • PDF

Design and Control of MR Military Suspension System Considering Friction Force (마찰력을 고려한 군용 MR 현수 장치의 설계 및 제어)

  • Ha, Sung-Hoon;Choi, Seung-Bok;Rhee, Eun-Jun;Kang, Pil-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.480-485
    • /
    • 2009
  • This paper presents dynamic modeling and control analysis of a military vehicle suspension featuring MR valve structure. Firstly, the dynamic model of the suspension system which is included gas spring, MR valve and gas chamber is established with respect to the disturbance. Secondly, the friction model of the suspension system is derived by considering experiment result of the MR suspension system. And then, response characteristics of the damping force with respect to the magnetic field and friction force with the proposed friction model are provided to show the feasibility of practical application. In addition, control performance of the proposed MR suspension system is evaluated with quarter vehicle.

  • PDF

Design and Control of MR Military Suspension System Considering Friction Force (마찰력을 고려한 군용 MR 현수 장치의 설계 및 제어)

  • Ha, Sung-Hoon;Choi, Seung-Bok;Rhee, Eun-Jun;Kang, Pil-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.58-65
    • /
    • 2010
  • This paper presents dynamic modeling and control analysis of a military vehicle suspension featuring MR valve structure. Firstly, the dynamic model of the suspension system which is included gas spring, MR valve and gas chamber is established with respect to the disturbance. Secondly, the friction model of the suspension system is derived by considering experiment result of the MR suspension system. And then, response characteristics of the damping force with respect to the magnetic field and friction force with the proposed friction model are provided to show the feasibility of practical application. In addition, control performance of the proposed MR suspension system is evaluated with quarter vehicle.

Micromagnetic Modeling of Spin-valve MR Head with Synthetic Antiferromagnet (SyAF)

  • Tahk, Y.W;Lee, K.J;Lee, T.D
    • Journal of Magnetics
    • /
    • v.7 no.2
    • /
    • pp.55-58
    • /
    • 2002
  • MR transfer behaviors of the permanent magnet biased spin valve MR sensors with SyAF (synthetic antiferromagnet) layers were studied by micromagnetics modeling. For narrow track MR heads, various height to width ratios were considered together with strength of permanent magnets which stabilities the free layed As the MR sensor width is reduced to $0.12 \mu{m}$, sensor height less than 0.09 ${\mu}{\textrm}{m}$ is needed to show good linearity and the Mr.t of permanent magnets smaller than 0.2 memu/$cm^2$ is sufficient for the domain stabilization. The conditions for single domain behavior of the free layer were also investigated through optimizing the biasing strength of permanent magneto the shield gap and the aspect ratio of MR sensor.