• Title/Summary/Keyword: MR Head

Search Result 178, Processing Time 0.021 seconds

Idiopathic Vestibular Disease in a Beagle Dog: Clinical Findings and Outcome (비글 견에서 발생한 특발성 전정계 질병 증례: 임상적 발견과 결과)

  • Kang, Byeong-Teck;Jung, Dong-In;Park, Chul;Gu, Su-Hyun;Jeon, Hyo-Won;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.340-343
    • /
    • 2006
  • A 10-year-old, intact female Beagle dog was presented for examination of acute onset of right-sided head tilt and moderate ataxia. Clinical signs were acutely presented 12 days ago and had been progressively alleviated until the admission day. The dog was bright, alert, and responsive. On neurological examinations, mild head tilt to the right and mild ataxia were noted, thus vestibular disorders were suspected. Central vestibular disease was ruled out based on the clinical signs, magnetic resonance imaging(MRI), and cerebrospinal fluid(CSF) analysis. Otoscopic examination showed that the tympanic membranes were intact and normal in appearance. On radiographic and MR examinations, abnormalities were not found in the tympanic bulla and the petrous portion of the temporal bone. Hypothyroidism was ruled out by thyroid-stimulation hormone(TSH) stimulation test. Clinical signs were completely disappeared at 2 weeks after discharge without any therapy. Thus, the dog was definitively diagnosed as idiopathic vestibular disease based on the clinical signs, excluding other causes of vestibular dysfunction, and the alleviation of clinical signs with time.

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

Clinical Studies of Cerebral Palsy (뇌성마비의 임상적 고찰)

  • Kang, Won Sik;Cheon, Kyong Whoon;Son, Byeong Hee;Kim, Sung Won
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.512-518
    • /
    • 2002
  • Purpose : Cerebral palsies are the most common and severe motor disabilities in childhood. There is currently increased interest in their occurrence and patterns of likely cause for a variety of reasons. Therefore, a retrospective study was carried out to understand the clinical features of cerebral palsy. Methods : A retrospective chart review was conducted of all children with cerebral palsy who were diagnosed at St. Benedict Hospital between March 1999 and March 2001. Results : Cerebral palsy patients were classified into 6 major groups. Of six groups, spastic diplegia is the most common type of cerebral palsy(55.3%). The risk factors of cerebral palsy were placenta previa(1 case), placenta abruption(1 case), cytomegalovirus infection(1 case), prematurity (53 cases), neonatal asphyxia(12 cases), dystocia(2 cases), breech delivery(1 case), multiple birth(5 cases), head trauma(3 cases), meningitis(2 cases) and unknown(26 cases). Among the 59 in the preterm group, 37 patients showed MR or CT images of periventricular leukomalacia. Among the 44 in the term group, 15 patients showed MR or CT images of atrophy. Among 103 patients, 29 patients(28.2%) had a seizure disorder. Conclusion : It is very importent to understand the clinical features and risk factors of cerebral palsy for physicians to diagnose and manage cerebral palsy patient.

VR, AR Simulation and 3D Printing for Shoulder and Elbow Practice (VR, AR 시뮬레이션 및 3D Printing을 활용한 어깨와 팔꿈치 수술실습)

  • Lim, Wonbong;Moon, Young Lae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.175-179
    • /
    • 2016
  • Recent advances in technology of medical image have made surgical simulation that is helpful to diagnosis, operation plan, or education. Improving and enhancing the medical imaging have led to the availability of high definition images and three-dimensional (3D) visualization, it allows a better understanding in the surgical and educational field. The Real human field of view is stereoscopic. Therefore, with just 2D images, stereoscopic reconstruction process through the surgeon's head, is necessary. To reduce these process, 3D images have been used. 3D images enhanced 3D visualization, it provides significantly shorter time for surgeon for judgment in complex situations. Based on 3D image data set, virtual medical simulations, such as virtual endoscopy, surgical planning, and real-time interaction, have become possible. This article describes principles and recent applications of newer imaging techniques and special attention is directed towards medical 3D reconstruction techniques. Recent advances in technology of CT, MR and other imaging modalities has resulted in exciting new solutions and possibilities of shoulder imaging. Especially, three-dimensional (3D) images derived from medical devices provides advanced information. This presentation describes the principles and potential applications of 3D imaging techniques, simulation and printing in shoulder and elbow practice.

Medical Image Compression Using JPEG International Standard (JPEG 표준안을 이용한 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yoen
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.504-506
    • /
    • 1993
  • The Joint Photographic Experts Group (JPEG) standard was proposed by the International Standardization Organization (ISO/SC 29/WG 10) and the CCITT SG VIII as an international standard for digital continuous-tone still image compression. The JPEG standard has been widely accepted in electronic imaging, computer graphics, and multi-media applications, however, due to the lossy character of the JPEG compression its application in the field of medical imaging has been limited. In this paper, the JPEG standard was applied to a series of head sections of magnetic resonance (MR) images (256 gray levels, $256{\times}256$ size) and its performance was investigated. For this purpose, DCT-based sequential mode of the JPEG standard was implemented using the CL550 compression chip and progressive and lossless coding was implemented by software without additional hardware. From the experiment, it appears that the compression ratio of about 10 to 20 was obtained for the MR images without noticeable distortion. It is also noted that the error signal between the reconstructed image by the JPEG and the original image was nearly random noise without causing any special-pattern-related artifact. Although the coding efficiency of the progressive and hierarchical coding is identical to that of the sequential coding in compression ratio and SNR, it has useful features In fast search of patient Image from huge image data base and in remote diagnosis through slow public communication channel.

  • PDF

Analysis of in vitro 2D-COSY on Human Brain Metabolites for Molecular Stereochemistry

  • Kim, Sang-Young;Woo, Dong-Cheol;Bang, Eun-Jung;Kim, Sang-Soo;Lim, Hyang-Sook;Choi, Chi-Bong;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.12 no.1
    • /
    • pp.14-25
    • /
    • 2008
  • To investigate the 3-bond connectivity of human brain metabolites by scalar coupling interaction through 2D-correlation spectroscopy (COSY) techniques using high field NMR spectroscopy. All NMR experiments were performed at 298K on Unity Inova 500 or 600 (Varian Inc.) equipped with a triple resonance probe head with z-shield gradient. Human brain metabolites were prepared with 10% $D_2O$. Two dimensional 2D COSY spectra were acquired with 4096 complex data points in $t_2$ and 128 or 256 increments in $t_1$ dimension. The spectral width was 9615.4 Hz and solvent suppression was achieved using presaturation using low power irradiation of the water resonance during 2s of relaxation delay. NMR data were processed using VNMRJ (Varian Instrument) software and all the chemical shifts were referenced to the methyl resonance of N-acetyl aspartate (NAA) peak at 2.0 ppm. Total 10 metabolites such as N-acetyl aspartate (NAA), creatine (Cr), choline (Cho), glutamine (Gln), glutamate (Glu), myo-inositol (Ins), lactate (Lac), taurine (Tau), ${\gamma}$-aminobutyricacid (GABA), alanine (Ala) were included for major target metabolites. Symmetrical 2D-COSY spectra were successfully acquired. Total 14 COSY cross peaks were observed even though there were parallel/orthogonal noisy peaks induced by water suppression. Except for Cr, all of human brain metabolites produced COSY cross peaks. The spectra of NAA methyl proton at 2.02 ppm and Glu methylene proton ($CH_2(3)$) at 2.11 ppm and Gln methylene proton ($CH_2(3)$) at 2.14 ppm were overlapped in the similar resonance frequency between 2.00 ppm and 2.15 ppm. The present study demonstrated that in vitro 2D-COSY represented the 3-bond connectivity of human brain metabolites by scalar coupling interaction. This study could aid in better understanding the interactions between human brain metabolites in vivo 2D-COSY study. Also it would be helpful to determine the molecular stereochemistry in vivo by using two-dimensional MR spectroscopy.

Study on the Improvement of Stow Net Fishing Technique and the Enlargement of Fishing Ground to the Distant Waters - 1 . Model Experiment of the Net - (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 1 . 어구의 모형실험 -)

  • Lee, Byoung-Gee;Kim, Jin-Kun;Lee, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.55-64
    • /
    • 1988
  • Stow nets have widely been used in the western sea of Korea from the olden age. The original structure of a stow net is a large square-sectional bag net made of 4 netting panels, and the front fringes of top and bottom panels are connected to the top and bottom beams respectively. Wire ropes, which is originated from the holding anchor are gradually forked and biforked, and finally 4 pieces of wire rope (biforked pendants) are jointed to each beam. Much convenience caused by long and heavy beams were problemed, then some studies have been carried out to improve the net since 1930's. The most effective improvement were achieved in 1980 by Mr. Han and his colleagues. The key point of improvement was that the beams were removed and the belt shaped shearing device made by canvas was attached to the side panels, the head rope and ground rope to the front fringe of top and bottom panel, and biforked pendants are joined to the shearing device. Even though this is the epoch-making improvement of a stow net, the further study should be required to find out more effective method. The authors carried out a model experiment on the stow net to determine the vertical and horizontal opening of a net mouth, and also examine the front, top and side-view configuration of the net. The model net was constructed depending on the Similarity Law of Fishing Gear in 1/10 and 1/20 scale and set against to the current at shallow and speedy flowing channel. The vertical and horizontal openings were determined by using scaled bamboo poles, and the configuration was observed by using specially prepared observation platform and underwater observation glass, and also photographed by using specially prepared underwater photographic equipment. The results obtained can be summarized as follows: 1. The opening height and width of the shearing device varied in accordance with the relative length of the biforked pendants. Considering the height and width of shearing device in 6 cases of the arrangement system of biforked pendants, the best result was obtained in the case that the 2nd, 3rd and 4th pendents from the bottom-most was 5%, 9% and 4% longer than that. 2. On the top-view configuration the excessive deformation of head rope and ground rope were observed. In the actual net, 54m long head rope and ground rope were attached to the front fringe of top and bottom panels so that the head rope may be lifted to make the net mouth open highly. But actually the head rope and the ground rope are streamed backward without any lift, and also the netting followed the ropes were deformed until the 2/5 in the whole length of the net. This deformation may be guessed to disturb the entrance of fish school into the net and also caused the net to get caught by obstacles in the sea bed and to be broken largely. 3. Hydrodynamic resistance R of the actual net may be deduced as R(kg)=29.2$\times$103 v1.65. It is also expressed as R(kg)=5.9$\times$d/l$\times$ab v1.65. depending on the formula deduced by Koyama to estimate the resistance of trawl nets, where d/l denote the ratio between diameter of netting twine and length of mesh leg in every part of side panel, a and b, the stretched circumference of the mouth and the stretched length of the net, respectively.

  • PDF

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Metastatic thyroid follicular carcinoma of masticator space (저작근극에서 발생한 전이된 갑상선 여포상암)

  • Gang Tae-In;Heo Min-Suk;An Chang-Hyeon;Choi Mi;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.175-179
    • /
    • 2002
  • Follicular carcinomas are the second most common form of thyroid cancer, accounting for 10 to 20% of all thyroid cancers. Follicular carcinomas have a propensity to metastasize via the bloodstream, spreading to bone, lungs, liver, and elsewhere. We described the case of a 48-year-old woman who presented with swelling of the left preauricular area, which was a consequence of a metastatic follicular carcinoma of the masticator space. Plain films showed illdefined erosive bony changes from the left condylar head to the mandibular notch. Contrast-enhanced CT images showed a well circumscribed round mass with well enhancement within left masticator space. On MR images, the mass was heterogenously hyperintense to the muscle on T2-weighted images and isointense or hyperintense to the muscle on Tl-weighted images, and showed good enhancement on contrast-enhanced Tl-weighted images. Upon microscopic examination, the metastatic mass was found to be composed of fairly uniform cells forming small follicles containing colloid, showing capsular and vascular invasion.

  • PDF