• Title/Summary/Keyword: MPA해석

Search Result 532, Processing Time 0.028 seconds

MPA-based IDA Using the Inelastic Displacement ratio, CR and the Collapse Intensity, RC (비탄성변위비와 붕괴강도비를 이용한 MPA기반의 IDA 해석법)

  • Han, Sang-Whan;Seok, Seung-Wook;Lee, Tae-Sub
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.33-39
    • /
    • 2010
  • This study develops an approximate procedure for incremental dynamic analysis (IDA) using modal pushover analysis (MPA) with empirical equations of the inelastic displacement ratio ($C_R$) and the collapse strength ratio ($R_C$). By using this procedure, it is not required to conduct linear or nonlinear response history analyses of multi- or single- degree of freedom (MDF) systems. Thus, IDA curves can be effortlessly obtained. For verification of the proposed procedure, the 6-, 9- and 20-story steel moment frames are tested under an ensemble of 44 ground motions. The results show that the MPA-based IDA with empirical equations of $C_R$ and $R_C$ produced accurate IDA curves of the MDF systems. The computing time is almost negligible compared to the exact IDA using repeated nonlinear response history analysis (RHA) of a structure and the original MPA-based IDA using repeated nonlinear RHA of modal SDF systems.

Design and Analysis of Micro-positioning Actuator using Three Dimensional Finite Element Method (3차원 유한요소법을 이용한 Micro positioning actuator의 설계 및 해석)

  • Oh, Kwang-Il;Rho, Jong-Seok;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.64-66
    • /
    • 2005
  • 본 논문에서는 압전체의 타원 운동을 이용한 선형 Micro-Positioning Actuator(MPA)에 대한 설계 및 해석 기법을 제안하였다. 또한 MPA의 해석을 위해 3차원 압전체의 유한요소의 정식화를 통한 유한요소 해석기법의 검증을 수행하였다. 검증된 3차원 유한요소 해석을 이용하여 MPA의 공진 특성 즉 impedance, 모드, 그리고 타원운동 해석을 하였다. 마지막으로 제안된 해석기법을 이용하여 기계 시스템을 고려한 MPA의 최종 설계를 하였다.

  • PDF

Experimental and Numerical Analysis of DME Spray Characteristics in Common-rail Fuel System (커먼레일 연료시스템에서의 DME 분무 특성에 대한 실험과 해석적 연구)

  • Jeong, Soo-Jin;Park, Jung-Kwon;Lee, Sang-In;Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1151-1159
    • /
    • 2012
  • Spray visualization and computer simulation of a DME injector have been conducted to investigate the enlarged injection hole diameter effect. To increase the reliability of the computational result, simulation results have been compared with the visualization test results, and the behaviors of a DME spray under various high-pressure and -temperature conditions have been computed. This study shows a discrepancy of 3.57% between the experimental and the computational results of penetration length for an injection pressure of 35 MPa and ambient pressure of 5 MPa. When simulating the engine conditions, the maximum penetration length of a fully developed DME spray is 42 mm when the temperature to pressure ratio is 300 K/MPa. The DME spray behavior is dominantly affected by the ambient pressure under the condition that the ratio is less than 300 K/MPa, and by the ambient temperature under the condition that the ratio is more than 300 K/MPa.

A Study on Thermal Analysis with Strength Characteristics of HPC Column with Fiber Cocktail in KS Fire Curve (표준화재조건에서 Fiber Cocktail을 혼입한 고강도 콘크리트 기둥의 강도별 전열특성에 관한 연구)

  • Kim, Heung-Youl;Chae, Han-Sik;Kim, Hyung-Jun;Jeon, Hyun-Kyu;Youm, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.397-400
    • /
    • 2008
  • To carry out this study efficiently, the material, physical and mechanical properties of the existing high temperature area was identified and the thermal transportation of structural elements was carried out through the finite element analysis method(ABAQUS) for 40 to 100 MPa high strength concrete based on Fiber Cocktail mixing. The results are as follows. First, it was analyzed that 40, 50 and 60 MPa high strength concretes have a thermal transportation properties similar to the analysis model of 30 MPa normal concrete. Second, it was analyzed that the analysis model of 80 and 100 MPa high strength concrete have slightly lower thermal transportation properties compared to normal model. Third, this study didn't consider the explosive spalling by the pore pressure within high strength concrete. If the properties for the pore pressure within high strength concrete is considered and database by strength and by inner temperature of various high strength concrete and steel materials are established in the future, it is interpreted that the technical foundation will be laid for performance-based design of fire-resistant construction.

  • PDF

An Analytical Study on Prediction Fire Resistance of CFT Column in ISO Fire (표준화재조건 CFT기둥 내화성능예측을 위한 해석적 연구)

  • Kim, Hyung-Jun;Kim, Heun-Youl
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.257-260
    • /
    • 2008
  • The heat resistance of steel materials tends to weaken due to its high heat transfer properties, which might result in deteriorated strength because of rapidly rising temperature on surface in a fire. Particularly in case of CFT column that bears tensile stress of the structure on its external steel members, a numerical analysis on deterioration of strength and variation of stress shall be first carried out to ensure the structure will have sufficient fire resistance. In the study, based on values obtained from the high temperature material property test of steel materials and concrete, the test to forecast the fire behavior of CFT column was conducted using a finite element analysis method (ABAQUS). An Analysis in a bid to predict the heat transfer and the behavior characteristics by varying the strength of the concrete filled to the range of 40MPA and 50MPA was carried out. As a result of analysis of CFT column on condition of 180-minute exposure under the standard fire condition, 123mm of strain appeared with 40MPA model, while 91mm contraction with 50MPA model.

  • PDF

Structural Stability Analysis of One-Touch Insertion Type Pipe Joint for Refrigerant (냉매용 원터치 삽입식 파이프 조인트의 안전성 구조해석)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.542-549
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the structural stability of the 6.35 and 15.88 socket models, which are integrated insert type connectors developed by a company, using FEM. For structural analysis, HyperMesh as pre-processor, HYPER VIEW as post-processor, and LS-DYNA as solver were used. Result: In the case of 6.35 socket, the maximum stresses at hook, holder and hinge were 95.02MPa, 19.59MPa and 44.01MPa, respectively, and in case of 15.88 socket, it was 127.7 MPa, 40.09MPa and 45.23MPa, respectively. Conclusion: Comparing the stress distribution of the two socket models, the stress in the 15.88 socket, which has a relatively large outer diameter, appears to be large overall, but it is significantly lower than the yield stress of each material, indicating that there is no problem in structural safety in both models.

Dynamic Characteristics of Space Framed Structures by Using Nonlinear Transient Analysis (비선형 과도해석을 이용한 스페이스 프레임 구조물의 동적특성)

  • Son, Jin Hee;Kim, Joo-Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.395-402
    • /
    • 2016
  • Space frame structures considering the components such as forms, layers, grids, etc. are possible to form a large space without interior columns. Here, steels having the yield strengths of 210 MPa to 450 MPa are generally used. The high strength steel (i.e., yield strength of 690 MPa) having suitable weldability, aseismicity and economics have been recently developed. In this paper, the high strength steel is applied to the space frame structures in order to analytically find out their transient responses considering the material and geometric nonlinearities. For various circular dome types of space frame structures, the modal analysis and nonlinear transient analysis are carried out using nonlinear three dimensional finite element analysis.

Stress analysis of bucket rotating part of the compact excavator (굴삭기 버킷 회전부의 응력해석)

  • Shin, Suk-Shin;Noh, Jong-Ho;Park, Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.178-182
    • /
    • 2013
  • In mining and its similar industries, compact excavators are used commonly in narrow working spaces, of which bucket must be rotated essentially. Considering of those applications, many kinds of the compact excavators have been developed, but any stress evaluation of bucket rotating part had not been attempted. In this study, using of the finite element method and Spare solver, stress analysis has been performed on the bucket rotating parts and its adjacent parts of compact excavator, with using an excavation stress model, in various directions and positions. Resultantly, it has been defined that stress of connector in the rotating part is a little higher, due to its shape, than those remained parts of which stress are shown equally as 1 MPa. Especially in the moving parts, the stress of bucket pin and rotating pinion gear has been calculated as 7.7 MPa and 40 MPa respectively.

Analysis of Vibration and Stress for Bed Structure of Engine Dynamo Tester (엔진 다이나모 시험기 베드 구조물의 진동 및 구조응력해석)

  • 이영신;강이석;김동진;김영대;김의석
    • Computational Structural Engineering
    • /
    • v.11 no.3
    • /
    • pp.173-185
    • /
    • 1998
  • 본 연구에서는 자동차엔진 및 트랜스미션 성능시험을 위한 다이나모 베드구조물을 분석하고 설계하였다. 해석상에 고려된 베드구조물은 Ⅰ형강 구조물, 보강된 박스구조물 그리고 블록구조물로 제작되었으며, 시험을 위한 엔진 및 트랜스미션은 베드상판에 장착된다. 엔진구동시 회전에 의한 진동이 발생된다. 공진을 피하기 위해 베드구조는 충분한 구조적 일체성을 가져야 한다. 본 연구에서는 베드 구조물의 응력, 변위 그리고 자유진동해석이 ANSYS Code를 이용한 유한요소해석이 수행되었다. Ⅰ형강 구조형 베드 구조물에서 최대 응력은 23.2MPa에서 90.3MPa까지 나타났으며, 최대 처짐은 0.25㎜에서 0.92㎜까지 나타났다. 박스 구조형 베드 구조물에서 최대 응력은 0.028MPa에서 0.259MPa까지 나타났으며, 최대 처짐은 0.031㎜에서 0.413㎜까지 나타났다. 그리고 박스구조형 베드 구조물에서 최대 처짐은 0.92MPa에서 2.15MPa까지 나타났으며, 최대 처짐은 1.1㎜에서 2.7㎜까지 나타났다. 모든 구조물이 응력과 처짐 값에서 매우 안정적인 범위 내에서 발생됨을 볼 수 있었다. 구조진동해석에서 Ⅰ형강 베드구조물의 고유진동수는 112.03㎐에서 141.66㎐까지의 범위에 발생되었다. 박스 구조형 베드구조물에서의 고유진동수는 396.93㎐에서 755.11㎐까지의 범위에서 발생되었다. 마지막으로 블록구조형 베드구조물에서는 266.51㎐에서 244.67㎐까지의 고유진동수를 찾을 수 있었다. 모든 구조물에서 베드구조물의 무게증가에 따른 기본진동수는 증가된다. 베드시스템의 지지기초시스템은 2자유도계 시스템으로 설계되었으며, 다양한 질량변화 및 스프링상수 변화에 따른 진동해석을 수행하였다. 질량비가 증가될수록 고유진동수는 크게 감소되며, 스프링상수가 증가될수록 고유진동수는 감소된다.

  • PDF

FE Analysis on the Sealing Characteristics of Multi-Contact Packing for Swivel Joint (스위블 연결구용 멀티접촉패킹의 밀봉특성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.51-55
    • /
    • 2014
  • This paper was analyzed for a sealing characteristics of single lip contact type o-ring and multiple lip contact type packing for a swivel joint using the finite element method. According to the FE analysis, a conventional o-ring produces a maximum contact normal stress of 2.5MPa for a supplied LP gas pressure of 1.8MPa, which is related to the sealing performance. But, a sealing performance of newly invented multi-lip packing produces a maximum contact normal stress of 3.01MPa, which is 20.4% higher than that of a conventional o-ring. And an extrusion of a conventional o-ring, which is strongly related to the sealing endurance safety, was occurred at a supplied gas pressure of 1.62MPa. But, a multi-lip packing does not produce up to the gas pressure of 1.8MPa. This means that a new type of multi-lip packing may have excellent sealing characteristics because of no extrusion for high gas pressure. Thus, multi-lip packing with multiple lip contacts may be useful for high sealing and endurance safety compared to that of the conventional o-ring with a single lip contact.