• Title/Summary/Keyword: MM5 Model

Search Result 1,665, Processing Time 0.038 seconds

Rainfall-Runoff Analysis of a Rural Watershed (농촌유역의 강우-유출분석)

  • Kim, Ji-Yong;Park, Ki-Jung;Chung, Sang-Ok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.93-98
    • /
    • 2001
  • This study was performed to analyse the rainfall and the rainfall-runoff characteristics of a rural watershed. The Sangwha basin($105.9km^{2}$) in the Geum river system was selected for this study. The arithmetic mean method, the Thiessen's weighing method, and the isohyetal method were used to analyse areal rainfall distribution and the Huff's quartile method was used to analyse temporal rainfall distribution. In addition, daily runoff analyses were peformed using the DAWAST and tank model. In the model calibration, the data from June through November, 1999 were used. In the model calibration, the observed runoff depth was 513.7mm and runoff rate was 45.2%, and the DAWAST model simulated runoff depth was 608.6mm and runoff rate was 53.5%, and the tank model runoff depth was 596.5mm and runoff rate was 52.5%, respectively. In the model test, the data from June through November, 2000 were used. In the model test, the observed runoff depth was 1032.3mm and runoff rate was 72.5%, and the DAWAST model simulated runoff depth was 871.6mm and runoff rate was 61.3%, and the tank model runoff depth was 825.4mm and runoff rate was 58%, respectively. The DAWAST and tank model's $R^{2}$ and RMSE were 0.85, 3.61mm, and 0.85, 2.77mm in 1999, and 0.83, 5.73mm, and 0.87, 5.39mm in 2000, respectively. Both models predicted low flow runoff better than flood runoff.

  • PDF

Investigation of the effects of particle size and model scale on the UCS and shear strength of concrete using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Lazemi, Hossein Ali
    • Structural Engineering and Mechanics
    • /
    • v.67 no.5
    • /
    • pp.505-516
    • /
    • 2018
  • In this paper, the effects of particle size and model scale of concrete has been investigated on the failure mechanism of PFC2D numerical models under uniaxial compressive test. For this purpose, rectangular models with same particle sizes and different model dimensions, i.e., $3mm{\times}6mm$, $6mm{\times}12mm$, $12mm{\times}24mm$, $25mm{\times}50mm$ and $54mm{\times}108mm$, were prepared. Also rectangular models with dimension of $54mm{\times}108mm$ and different particle sizes, i.e., 0.27 mm, 0.47 mm, 0.67 mm, 0.87 mm, 1.07 mm, 1.87 mm and 2.27 mm were simulated using PFC2D and tested under uniaxial compressive test. Concurrent with uniaxial test, direct shear test was performed on the numerical models. Dimension of the models were $75{\times}100mm$. Two narrow bands of particles with dimension of $37.5mm{\times}20mm$ were removed from upper and lower of the model to supply the shear test condition. The particle sizes in the models were 0.47 mm, 0.57 mm, 0.67 mm and 0.77 mm. The result shows that failure pattern was affected by model scale and particle size. The uniaxial compressive strength and shear strength were increased by increasing the model scale and particle size.

Optical constant of the reduced eye based on theoretical finite model eye (이론적 정밀모형안에 기초한 환산모형안의 광학상수)

  • 김상기
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.268-273
    • /
    • 2004
  • A finite model eye based on longitudinal spherical aberration is designed by an optimization method. Longitudinal spherical aberration for pupil diameter between 1 mm and 8 mm is graphed theoretically and compared with other model eyes. The chromatic dispersions are adjusted to fit experimentally observed chromatic aberration of the eye. This is a finite model eye with four a spheric refracting surfaces. It has an effective focal length of 15.842 mm. A designed reduced eye has an equivalent power of 63.12 Diopter, curvature radius of 5.281 mm, index of 1.33333, and axial length of 21.123 mm.

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

Breakdown Characteristics of Insulators for a Resistor Type HTS Fault Current Limiter (저항형 고온초전도 한류기용 절연체의 절연 특성)

  • 백승명;류엔반둥;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.48-52
    • /
    • 2004
  • Breakdown characteristics of insulator-liquid nitrogen ($LN_2$) composite insulation for resistor type High $T_c$/ superconducting fault current limiter (HTSFCL) under ac and impulse voltage in $LN_2$ has been studied using model electrode systems. Electrodes for model electrode systems were made of SUS 304 contacted fiberglass reinforced plastic (FRP) and Au coated sapphire. The breakdown characteristics of model electrode systems were investigated experimentally for FRP thickness ranging from 1 mm to 5 mm. surface distance ranging from 2.5 mm to 7 mm and electrode gap ranging from 1 to 5 mm. The experimental data suggested that the breakdown voltage of model electrode systems in $LN_2$ is highly dependent on the surface distance, electrode gap as well as on the FRP thickness. Also, we had observed discharge traces and puncture due to high-voltage 60-Hz AC stress.

A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data (발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구)

  • Park, Hae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Investigation of the model scale and particle size effects on the point load index and tensile strength of concrete using particle flow code

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Hedayat, Ahmadreza;Marji, Mohammad Fatehi
    • Structural Engineering and Mechanics
    • /
    • v.66 no.4
    • /
    • pp.445-452
    • /
    • 2018
  • In this paper the effects of particle size and model scale of concrete have been investigated on point load index, tensile strength, and the failure processes using a PFC2D numerical modeling study. Circular and semi-circular specimens of concrete were numerically modeled using the same particle size, 0.27 mm, but with different model diameters of 75 mm, 54 mm, 25 mm, and 12.5 mm. In addition, circular and semi-circular models with the diameter of 27 mm and particle sizes of 0.27 mm, 0.47 mm, 0.67 mm, 0.87 mm, 1.07 mm, and 1.27 mm were simulated to determine whether they can match the experimental observations from point load and Brazilian tests. The numerical modeling results show that the failure patterns are influenced by the model scale and particle size, as expected. Both Is(50) and Brazilian tensile strength values increased as the model diameter and particle sizes increased. The ratio of Brazilian tensile strength to Is(50) showed a reduction as the particle size increased but did not change with the increase in the model scale.

Transient Middle Cerebral Artery Occlusion Model in Mouse using Nylon Thread (Nylon Thread를 이용한 mouse 에서의 Transient middle cerebral artery occlusion (MCAO) model 확립)

  • Lim, Byung-Chul;Sung, Ji-Hee;Kim, Ha-Na;Park, Seoung-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.7
    • /
    • pp.186-191
    • /
    • 2019
  • Introduction: In aged people, stroke incidence is increased. But standardized experimental animal protocol study for the research of stroke therapy is rare. There is little report on the success rate of cerebral artery occlusion model using standardized Nylon thread length of precise thread end-size controlled. Method: In this study, the operator intended the occlusion of middle cerebral artery (MCA) using $0.18{\pm}0.02mm$ end 5-0 Nylon thread. Middle cerebral artery occlusion was induced for 60min under isoflurane anesthesia. After 60min, the operator removed the Nylon thread and reperfusion was induced for 23hrs. The mice was killed 23hrs after reperfusion and infarction area of brain was confirmed by 1.5% TTC (2,3,5-tryphenyl tetrazolium chloride) staining. Results: According to end size and insert length of Nylon thread, Middle cerebral artery occlusion (n=50), internal carotid artery occlusion (n= 14), distal middle cerebral artery occlusion (n= 36), anterior cerebral artery (n= 1) were induced. And no infarction (n= 50) was observed. Conclusion: According to weight of mice, the operator induced reversible cerebral artery occlusion model by different insert length (30.0~36.9g : 9.0mm, 37.0~40.0g : 9.5mm) of Nylon thread. Success of cerebral artery occlusion model was confirmed by checking infarction area using TTC staining. The success rate (66.9%, 101/151) of reversible cerebral artery occlusion model in the mouse and the operational conditions are shown.

Development of a Dynamic Downscaling Method using a General Circulation Model (CCSM3) of the Regional Climate Model (MM5) (전지구 모델(CCSM3)을 이용한 지역기후 모델(MM5)의 역학적 상세화 기법 개발)

  • Choi, Jin-Young;Song, Chang-Geun;Lee, Jae-Bum;Hong, Sung-Chul;Bang, Cheol-Han
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.79-91
    • /
    • 2011
  • In order to study interactions between climate change and air quality, a modeling system including the downscaling scheme has been developed in the integrated manner. This research focuses on the development of a downscaling method to utilize CCSM3 outputs as the initial and boundary conditions for the regional climate model, MM5. Horizontal/vertical interpolation was performed to convert from the latitude/longitude and hybrid-vertical coordinate for the CCSM3 model to the Lambert-Conformal Arakawa-B and sigma-vertical coordinate for the MM5 model. A variable diagnosis was made to link between different variables and their units of CCSM and MM5. To evaluate the dynamic downscaling performance of this study, spatial distributions were compared between outputs of CCSM/MM5 and NRA/MM5 and statistic analysis was conducted. Temperature and precipitation patterns of CCSM/MM5 in summer and winter showed a similar pattern with those of observation data in East Asia and the Korean Peninsula. In addition, statistical analysis presented that the agreement index (AI) is more than 0.9 and correlation coefficient about 0.9. Those results indicate that the dynamic downscaling system built in this study can be used for the research of interaction between climate change and air quality.

Intercomparison of Wind and Air Temperature Fields of Meteorological Model for Forecasting Air Quality in Seoul Metropolitan Area (수도권지역 대기질 예측을 위한 기상장 모델의 바람장과 온도장 비교 연구)

  • Jeong, Ju-Hee;Kim, Yoo-Keun;Moon, Yun-Seob;Hwang, Mi-Kyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.640-652
    • /
    • 2007
  • The MM5, RAMS and WRF, meteorological models have provided the dynamical parameters as inputs to air quality model. A major content of this study is that significant characteristics of three models for high-ozone occurrence analyze for surface wind and air temperature fields and compare with observation data in Seoul metropolitan area. An analysis of air temperature field revealed that location of core in high temperature of MM5 and WRF differed from that of RAMS. MM5 and WRF indicated high temperature in Seoul but RAMS represented it on the outskirts of Seoul. MM5 and WRF were underestimated maximum temperature during daytime but RAMS simulated similar value with observation data. Surface wind field with three models, it was shown many differences at horizontal distribution of wind direction. RAMS indicated weak wind speed in land and strong sea breeze at coastal areas than MM5 and WRF. However wind speed simulated by three model were overestimated during both daytime and nighttime.