• 제목/요약/키워드: MM(coated mortar)

검색결과 7건 처리시간 0.025초

규산질비분말혼합시멘트계도포방수재료를 도포한 몰탈 조직에서의 결정생성 평가 (Estimation of Crystal Production in Microstructure of Mortar Cooated with Siliceous Slurry Coatings)

  • 오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.89-92
    • /
    • 1993
  • This paper deals with the effect of siliceous slurry coatings on mortar microstructure under a damp environment. For estimation on effect of siliceous slurry coating, microstructure of coated mortar was observed through SEM. Crystal production in mivrosturcture of coated mortar was periodically increased, and more produced in mortar of high water-cement ratios. And they were generated mainly in mortar ranging from the surface to the inside about 2.5 or 3mm deep.

  • PDF

과도전자탐사법에 의한 모르타르 중의 코팅 철근의 부식 측정 방법 개발 (The Development of Measuring Method of Coated Steel Corrosion in Mortar by Transient Electro-Magnetic(TEM) Method)

  • 이상호;한정섭
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.108-115
    • /
    • 1999
  • To study measurement of coated steel corrosion in mortar, a transient electro-magnetic(TEM) method was adapted. The sensors were made of enamelled wire with diameter of 0.25mm(transmitter), 0.1mm(receiver) and the secondary electro motive force(EMF) was measured with SIROTEMIII. The sensors configuration was used as in loop configuration. After coated steels were corroded by the salt spray during 3, 7, 15, 25days, they were embedded in mortar which were made from sand : cement : water ratio of 2 : 1 :0.5. To investigate coated steel corrosion in mortar, the sensors were used. ( sensorl - $T_x$ : $4{\Omega}$, $R_x$ : $10{\Omega}$, $3{times}3cm$, sensor2 - $T_x$ : $8{\Omega}$, $R_x$ : $10{\Omega}$, $3{times}3cm$, sensor3 - $T_x$ : $4{\Omega}$, $R_x$ : $10{\Omega}$, $6{times}6cm$, sensor4 - $T_x$ : $8{\Omega}$, $R_x$ : $10{\Omega}$, $6{times}6cm$). The obtained results showed that the secondary EMF was decreased with specimens of 3, 7days corroded coationg steel in mortar and then increased with specccimens of 15, 25days corroded one. And it was confirmed that measurement of coated steel corrosion in mortar by a transient electro-magnetic(TEM) method is possible.

  • PDF

우레탄계와 아크릴계 도막 방수재가 도포된 바탕 모르타르의 염해 저항성 평가 (Salt damage resistance of mortar substrate coated by the urethane and acrylic waterproofing membranes)

  • 이준;미야우치 히로유키;구경모;최경철;미야우치 카오리;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.329-331
    • /
    • 2013
  • The salt damage resistance of waterproofing membrane was evaluated on the cracked mortar substrate. The types of specimens are urethane, acrylic waterproofing membrane, and no coating mortar substrate. After these specimens were cured by water curing for 4 weeks, they were cured by atmospheric curing at 20±2Co for 8 weeks. The salt water immersion test was carried out by following KS F 2737, and the penetration depth of chloride ion into substrate was measured in 1, 4, 8, and 13 weeks. As a result, in the case of non coating specimen, the chloride ion penetrated within one week. In the coated specimens, a regardless of the membrane type, the chloride ion did not penetrate during 13 weeks-tests on condition that the cracked width of substrate is less than 0.3mm. Also, the penetration speeds of the coated specimens were lower than that of non coating specimen. Therefore, our results reached a conclusion that waterproofing membrane has high salt damage resistance.

  • PDF

Corrosion Inhibition of Steel Rebar in Concrete with the Coated MCI 2022

  • Bezad Bavarian;Lisa Reiner;Kim, Chong Y.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.63-67
    • /
    • 2002
  • The induced chemical and salt solution in water or admixture are originated to the corrosion process of the steeo rebar. These liquids penetrate into concrete as the accompanied by the chemical reaction and cause to attack the steel rebar in concrete. Concrete surfaces which it exposed to deicing, water and sea water is allowed to enter the chlorides in the structures. To prevent from the source of corrosion and deterioration Is subjected to put an end to corrode or reduce to contaminate on the steel rebar. As this reason the MCI 2022 products are applied to the surface of concrete and steel rebar. The concrete samples were made of to the kind of four, i.e. RF, MR, MS, and MM. Corrosion inhibitor is applied to coat on the surface of concrete after it had been cured for 28days. Specimen were immersed in a 3.5% sodium chloride solution. Concrete specimen were tested to determine the changes of the resistance polarization, Rp, over a 22 weeks period. MCI 2022 is significantly shown the corrosion inhibition of steel rebar in 3.5% NaCl solution. In the each different concrete sample, MS and MM is seemed to be better than others. The results are proofed that MCI 2022 is promised to maintain the inhibition of corrosion with high resistance polarization of the steel rebar in concrete.

  • PDF

고강도 콘크리트 내화피복 특성연구 (A study on the characteristic of fire protection covering for high strength concrete)

  • 송영찬;이세현;김우재;양완희;박동철;백병훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.429-432
    • /
    • 2006
  • In this study a board was made with good fireproof materials of which test was conducted according to the fireproof test for KS F 2257 construction members, and the temperature in coated steel which has a possibility to explode with concrete surface was measured. It is not appropriate to use normal mortar or mortar covering mixed with P.P. fiber to take a measure to prevent the explosive splalling of high-strength concrete. To finalize an Al-Si (aluminosilicates) board-requires over 30mm in thickness at the minimum for the required fire resistance performance and explosion prevention.

  • PDF

Flexural response of steel beams strengthened by fibre-reinforced plastic plate and fire retardant coating at elevated temperatures

  • Ahmed, Alim Al Ayub;Kharnoob, Majid M.;Akhmadeev, Ravil;Sevbitov, Andrei;Jalil, Abduladheem Turki;Kadhim, Mustafa M.;Hansh, Zahra J.;Mustafa, Yasser Fakri;Akhmadullina, Irina
    • Structural Engineering and Mechanics
    • /
    • 제83권4호
    • /
    • pp.551-561
    • /
    • 2022
  • In this paper, the effect of fire conditions according to ISO 834 standard on the behavior of carbon fibre-reinforced plastic (CFRP) reinforced steel beams coated with gypsum-based mortar has been investigated numerically. To study the efficiency of these beams, 3D coupled temperature-displacement finite element analyzes have been conducted. Mechanical and thermal characteristics of three different parts of composite beams, i.e., steel, CFRP plate, and fireproof coating, were considered as a function of temperature. The interaction between steel and CFRP plate has been simulated employing the adhesion model. The effect of temperature, CFRP plate reinforcement, and the fireproof coating thickness on the deformation of the beams have been analyzed. The results showed that within the first 120 min of fire exposure, increasing the thickness of the fireproof coating from 1 mm to 10 mm reduced the maximum temperature of the outer surface of the steel beam from 380℃ to 270℃. This increase in the thickness of the fireproof layer decreased the rate of growth in the temperature of the steel beam by approximately 30%. Besides excellent thermal resistance and gypsum-based mortar, the studied fireproof coating method could provide better fire resistance for steel structures and thus can be applied to building materials.

균질한 품질 확보와 분진 저감을 위한 2성분 박층 뿜칠 라이너의 개발과 성능평가 (Development and Performance Evaluation of a Two-component Thin Spray-on Liner to Guarantee Its Homogeneous Qualities and to Reduce Dust)

  • 장수호;최순욱;이철호;강태호;황귀성;김진태;최명식
    • 터널과지하공간
    • /
    • 제26권5호
    • /
    • pp.441-453
    • /
    • 2016
  • 본 연구에서는 분진을 저감시킬 수 있고 균질한 품질을 확보하는 데 적합한 2성분 박층 뿜칠 라이너(TSL)를 개발하고 그 성능을 평가하였다. 2성분 TSL 시작품의 인장강도는 분말 1성분 TSL보다 다소 낮게 나타났으나, 높은 연성으로 인해 파괴 시의 신장률이 크게 측정되었다. 이외에도 EFNARC(2008)에서 제시하고 있는 성능기준들을 만족하였으며, 두께 3 mm로 피복한 코팅 압축시험 결과, 재령 28일의 평균 압축강도가 50% 이상 향상되는 것으로 확인되었다. 시험타설을 통해 본 연구에서 개발된 2성분 TSL 시작품에 적합한 타설장비를 도출하였으며, 실제 현장시공을 통해 2성분 TSL 타설 시의 분진과 리바운드가 극히 미미함을 확인하였다. 2성분 TSL의 타설속도는 $60m^2/hr$이었으며 일반적인 뿜칠 방수 멤브레인과 비교할 때 빠른 경화 특성을 나타내었다.