• Title/Summary/Keyword: ML 검출

Search Result 521, Processing Time 0.022 seconds

Implementation of Noise Predictive Maximum Likelihood Detector in High Density Perpendicular Magnetic Recording (고밀도 수직자기기록에서 잡음 예측 최대 유사도 시스템에 대한 검출기 구현)

  • 김성환;이재진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.336-342
    • /
    • 2003
  • Noise predictive maximum likelihood(NPML) detector embeds noise prediction/whitening process in branch metric calculation of Viterbi detector and improves the reliability of branch metric computation. Therefore, PRML detector with a noise predictor achieves some performance improvement and has an advantage of low complexity. This thesis random sequences are applied to linear channel. In perpendicular magnetic recording density KP=2.5, NP(121)ML and NP(1221)ML detection system which is based on a noise predictive PR-equalized signal are evaluated by the Performance through a computing simulation. Therefore, NPML systems are implemented and are verified by VHDL.

A Study on Cell ID Detection Scheme Using Synchronization Signals for 5G NR System (5G NR 시스템을 위한 동기 신호를 이용한 cell ID 검출을 위한 방법 연구)

  • Ahn, Haesung;Cha, Eunyoung;Kim, Hyeongseok;Kim, Jeongchang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.593-595
    • /
    • 2020
  • 본 논문에서는 5G NR 시스템을 위한 동기 신호를 이용한 cell ID 검출 방법에 대한 성능을 비교하였다. 5G NR(fifth-generation new radio) 시스템의 송신기는 SS/PBCH (synchronization signal/physical broadcast channel) 블록을 송신하며, 수신기는 수신된 SS/PBCH 블록을 이용하여 주파수 및 타이밍 오프셋 (frequency and timing offset)을 추정 할 수 있으며, cell ID (cell identity)는 PSS (primary synchronization signal)와 SSS (secondary synchronization signal)를 통해 검출할 수 있다. 본 논문에서는 cell ID 를 검출할 수 있는 방법으로서 2-stage 디코딩 방법과 결합 최대우도 결정 규칙 (joint maximum-likelihood decision rule: joint ML) 디코딩 방법을 사용하였다. Joint ML 디코딩 방법은 2-stage 디코딩 방법에 비해 더 좋은 검출 성능을 보이지만, 복잡도 측면에서는 2-stage 디코딩 방법이 joint ML 디코딩 방법에 비해 더 낮은 복잡도를 갖는 것을 확인하였다.

  • PDF

The Improved Method for Precise Determination of Pu Isotope Ratio using MC-ICP-MS (다중검출기유도결합플라즈마질량분석기를 이용한 Pu 동위원소비 정밀 분석법)

  • Yim, Seong-A;Han, Eun-Mi;Chae, Jung-Seok;Yun, Ju-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.117-123
    • /
    • 2010
  • Plutonium is by far the most important of the transuranic elements which have been released into the environment due to radio-toxicity and long term radiation effects on humans. And Pu isotope ratio ($^{240}Pu/^{239}Pu$) is of great interest because this ratio is used as a fingerprint for different sources. Mass spectrometry has been used as an useful atom counting technique with several advantages over decay counting techniques for the determination of Pu isotopes. It enables a determination of Pu isotope ratio in the environmental samples with a low detection limit and a short determination time. An ICP-MS is the representative mass spectrometry for Pu determination. In this study, the precision of $^{240}Pu/^{239}Pu$ isotope ratio was improved by using 4 multiple ion counters of MC-ICP-MS. The detection limit of $^{239}Pu$ and $^{240}Pu$ were $0.10\;fg\;ml^{-1}$ ($0.24\;{\mu}Bq\;ml^{-1}$), $0.12\;fg\;ml^{-1}$ ($0.97\;{\mu}Bq\;ml^{-1}$), respectively. The relative standard deviation of $^{240}Pu/^{239}Pu$ isotope ratio was less than 1 % in trace level. The various reference materials (seawater, soil and sediment) were analyzed to verify this method and their analytical results were in good agreement with the certified (or recommended value) value.

Linear Detection Method Based on Semi-Definite Relaxation of 16-QAM in MIMO Systems (MIMO 시스템에서 16-QAM의 Semi-Definite Relaxation에 기반을 둔 선형 검출 기법)

  • Lee, Ki-Jun;Byun, Youn-Shik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.700-705
    • /
    • 2012
  • This paper suggests the detecting method in which it uses the candidate symbol obtained through PI-SDR, the little computational complexity is required. By using the candidate symbol matrices obtained through PI-SDR, ZF and MMSE method was applied and the received signal was detected. The linear detecting method using PI-SDR candidate symbol is out of the performance than ML detecting method but the complexity is low. Because of using the symbol come close to the solution of ML, the proposed method's performance is better than the existing ZF and MMSE method.

A Computationally Efficient Signal Detection Method for Spatially Multiplexed MIMO Systems (공간다중화 MIMO 시스템을 위한 효율적 계산량의 신호검출 기법)

  • Im, Tae-Ho;Kim, Jae-Kwon;Yi, Joo-Hyun;Yun, Sang-Boh;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7C
    • /
    • pp.616-626
    • /
    • 2007
  • In spatially multiplexed MIMO systems that enable high data rate transmission over wireless communication channels, the spatial demultiplexing at the receiver is a challenging task, and various demultiplexing methods have been developed recently by many researchers. Among the previous methods, maximum likelihood detection with QR decomposition and M-algorithm (QRM-MM)), and sphere decoding (SD) schemes have been reported to achieve a (near) maximum likelihood (ML) performance. In this paper, we propose a novel signal detection method that achieves a near ML performance in a computationally efficient manner. The proposed method is demonstrated via a set of computer simulations that the proposed method achieves a near ML performance while requiring a complexity that is comparable to that of the conventional MMSE-OSIC. We also show that the log likelihood ratio (LLR) values for all bits are obtained without additional calculation but as byproduct in the proposed detection method, while in the previous QRM-MLD, SD, additional computation is necessary after the hard decision for LLR calculation.

Preconcentration of Copper(II) Using Mesoporous Organo-Silicas and Determination by Flame Atomic Absorption Spectrometry (메조다공성 유기-실리카를 이용한 구리(II)의 예비농축과 불꽃원자 흡수분광법으로의 정량)

  • Moghimi, Ali
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.155-163
    • /
    • 2008
  • .A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(II) ions using mesoporous organo-silicas mesoporous silica and atomic absorption spectrometry is presented. Common coexisting ions did not interfere with the separation and determination. The preconcentration factor was 100 (1 ml elution volume) for a 100 ml sample volume. The limit of detection of the proposed method is 1.0 ng ml-1. The maximum sorption capacity of sorbent under optimum conditions has been found to be 5mg of copper per gram of sorbent. The relative standard deviation under optimum conditions was 2.8% (n=10). Accuracy and application of the method was estimated by using test samples of natural and synthetic water spiked with different amounts of copper(II) ion.

Study on the Hazardous Heavy Metals from Porcelain Dinnerwares (주방용 도자기에서의 유해중금속 용출에 관한 조사연구)

  • 이광호;권기성;전대훈;정동윤;최병희;이선희;이철원
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.324-327
    • /
    • 2000
  • The analysis of hazardous heavy metals, such as Pb, Cd and As, was conducted from the porcelain dinnerwares. Total 374 samples of those products in the domestic market were purchased for the study. All the samples were extracted by 4% acetic acid solution, followed by the analysis with AAS(Atomic Absorption Spectroscopy). As a result, Pb and As were detected maximum 8.63$\mu\textrm{g}$/ml, 2.58 ng/ml, respectively. Cd was fecund in a sample as 0.10$\mu\textrm{g}$/ml.

  • PDF

A PRML System for Perpendicular Magnetic Recording Channel in Wireless Multimedia Networks (무선 멀티미디어 네트워크에서 수직 자기기록장치를 위한 PRML 시스템)

  • Kim Jeong-so;Hwang Gi-yean
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.454-457
    • /
    • 2004
  • Partial response maximum likelihood (PRML) is a powerful and indispensable detection scheme for perpendicular magnetic recording channels. The proposed method is a low complexity detection scheme which is related to the PRML system. The simulation results show that PR(1,2,3,4,3,2,1)ML and PR(l,2,3,3,2,1)ML using modulation encoding with R=2/3 have the most improved performance at K=3,4. However, in the case of K=3, R=2/3 PR(1,1,1,1)ML effectively reduces the complexity compared to PR(1,2,3,3,2,1), but it has L5dB performance degradation at most. In the case of K=4, R=l PR(1,2,2,1)ML has very low complexity compared to R=2/3 PR(l,2,3,4,3,2,1)ML. but it has about 2dB performance degradation at most.

  • PDF

Lattice Reduction Aided MIMO Detection using Seysen's Algorithm (Seysen 알고리즘을 이용한 Lattice Reduction-aided 다중 안테나 검출기법)

  • An, Hong-Sun;Mohaisen, Manar;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6C
    • /
    • pp.642-648
    • /
    • 2009
  • In this paper, we use SA (Seysen's Algorithm) instead of LLL (Lenstra-Lenstra-Lovasz) to perform LRA (Lattice Reduction-Aided) detection. By using SA, the complexity of lattice reduction is reduced and the detection performance is improved Although the performance is improved using SA, there still exists a gap in the performance between SA-LRA and ML detection. To reduce the performance difference, we apply list of candidates scheme to SA-LRA. The list of candidates scheme finds a list of candidates. Then, the candidate with the smallest squared Euclidean distance is considered as the estimate of the transmitted signal. Simulation results show that the SA-LRA detection learn to quasi-ML performance. Moreover, the efficiency of the SA is shown to highly improve the channel matrix conditionality.

A Gas Chromatographic Detector using Glow Discharge (글로우 방전을 이용한 기체크로마토그라피 검출기)

  • Han Chong Soo;Song, Seung Ho
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.350-354
    • /
    • 1991
  • Characteristics of a gas chromatographic detector using glow discharge as the ionization source was studied in helium flow. Discharge current greater than 10$_6$ A was observed from the electric field 400 V/mm for the electrode distance 1 mm. The discharge current of 0.1~0.3 mA could be used for the detection of organic compounds. Discharge current was almost constant for the helium flow rate greater than 10 ml/min, but the discharge was easily disappeared by an injection of a small amount of organic compound in the flow rate of 0~30 ml/min. From the decrement of the discharge current depend on several compounds, it was suggested that the sensitivity of the glow discharge ionization chromatographic detector is strongly influenced by the molecular weight of the compounds.

  • PDF