• Title/Summary/Keyword: MIT-BIH

Search Result 144, Processing Time 0.026 seconds

A Comparative Study on the Optimal Model for abnormal Detection event of Heart Rate Time Series Data Based on the Correlation between PPG and ECG (PPG와 ECG의 상관 관계에 기반한 심박 시계열 데이터 이상 상황 탐지 최적 모델 비교 연구)

  • Kim, Jin-soo;Lee, Kang-yoon
    • Journal of Internet Computing and Services
    • /
    • v.20 no.6
    • /
    • pp.137-142
    • /
    • 2019
  • This paper Various services exist to detect and monitor abnormal event. However, most services focus on fires and gas leaks. so It is impossible to prevent and respond to emergency situations for the elderly and severely disabled people living alone. In this study, AI model is designed and compared to detect abnormal event of heart rate signal which is considered to be the most important among various bio signals. Specifically, electrocardiogram (ECG) data is collected using Physionet's MIT-BIH Arrhythmia Database, an open medical data. The collected data is transformed in different ways. We then compare the trained AI model with the modified and ECG data.

A Study on the Holter Data Compression Algorithm -Using Piecewise Self-Affine Fractal Model- (Holter Data 압축 알고리즘에 관한 연구 -Piecewise Self-Affine Fractal Model을 이용한-)

  • 전영일;정형만
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.17-24
    • /
    • 1995
  • This paper presents a new compression method (or ECG data using iterated contractive transformations. The method represents any range of ECG signal by piecewise self-afrine fractal Interpolation (PSAFI). The piecewise self-afrine rractal model is used where a discrete data set is viewed as being composed of contractive arfine transformation of pieces of itself. This algorithm was evaluated using MIT/BIH arrhythmia database. PSAFI is found to yield a relatively low reconstruction error for a given compression ratio than conventional direct compression methods. The compression ratio achieved was 883.9 bits per second (bps) - an average percent rms difference (AFRD) of 5.39 percent -with the original 12b ECG samples digitized at 400 Hz.

  • PDF

A study on eliminating baseline wander of ECG using approximated S-wave contour (근사 S-파 궤적을 이용한 심전도의 기저선 변동 제거에 관한 연구)

  • Ju, Jangkyu;Lee, Ki Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.33-38
    • /
    • 2008
  • The baseline wander of ECG makes difficult to detect P-, Q-, R- and S-wave. This paper presents and compares two method to remove the baseline wander of ECG using slope traceing waves. For the first method that had been proposed already[1], the ascending slope tracing method is used to eliminate baseline wander. And the second method employs the contour of the approximated S-wave to remove baseline wander. These two methods are common to use the slope tracing wave. However, the first one is to get difference signals between the ascending tracing waves and ECG signals, and the other is to remove baseline wander using the contour of the approximated S-wave obtained from descending slope waves. To evaluate these methods, we apply to MIT/BIH database.

  • PDF

Arrhythmia Detection Using Rhythm Features of ECG Signal (심전도 신호의 리듬 특징을 이용한 부정맥 검출)

  • Kim, Sung-Oan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.8
    • /
    • pp.131-139
    • /
    • 2013
  • In this paper, we look into previous research in relation to each processing step for ECG diagnosis and propose detection and classification method of arrhythmia using rhythm features of ECG signal. Rhythm features for distribution of rhythm and heartbeat such as identity, regularity, etc. are extracted in feature extraction, and rhythm type is classified using rule-base constructed in advance for features of rhythm section in rhythm classification. Experimental results for all of rhythm types in the MIT-BIH arrhythmia database show detection performance of 100% for arrhythmia with only normal rhythm rule and applicability of classification for rhythm types with arrhythmia rhythm rules.

R Wave Detection and Advanced Arrhythmia Classification Method through QRS Pattern Considering Complexity in Smart Healthcare Environments (스마트 헬스케어 환경에서 복잡도를 고려한 R파 검출 및 QRS 패턴을 통한 향상된 부정맥 분류 방법)

  • Cho, Iksung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • With the increased attention about healthcare and management of heart diseases, smart healthcare services and related devices have been actively developed recently. R wave is the largest representative signal among ECG signals. R wave detection is very important because it detects QRS pattern and classifies arrhythmia. Several R wave detection algorithms have been proposed with different features, but the remaining problem is their implementation in low-cost portable platforms for real-time applications. In this paper, we propose R wave detection based on optimal threshold and arrhythmia classification through QRS pattern considering complexity in smart healthcare environments. For this purpose, we detected R wave from noise-free ECG signal through the preprocessing method. Also, we classify premature ventricular contraction arrhythmia in realtime through QRS pattern. The performance of R wave detection and premature ventricular contraction arrhythmia classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30 premature ventricular contraction. The achieved scores indicate the average of 98.72% in R wave detection and the rate of 94.28% in PVC classification.

Baseline Wander Removing Method Based on Morphological Filter for Efficient QRS Detection (효율적인 QRS 검출을 위한 형태 연산 기반의 기저선 잡음 제거 기법)

  • Cho, Ik-Sung;Kim, Joo-Man;Kim, Seon-Jong;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.166-174
    • /
    • 2013
  • QRS detection of ECG is the most popular and easy way to detect cardiac-disease. But it is difficult to analyze the ECG signal because of various noise types. The important problem in recording ECG signal is a baseline wandering, which is occurred by rhythm of respiration and muscle contraction attaching to an electrode. Particularly, in the healthcare system that must continuously monitor people's situation, it is necessary to process ECG signal in realtime. In other words, the design of algorithm that exactly detects QRS region using minimal computation by analyzing the person's physical condition and/or environment is needed. Therefore, baseline wander removing method based on morphological filter for efficient QRS detection method is presented in this paper. For this purpose, we detected QRS through the preprocessing method using morphological filter, adaptive threshold, and window. The signal distortion ratio of the proposed method is compared with other filtering method. Also, R wave detection is evaluated by using MIT-BIH arrhythmia database. Experiment result show that proposed method removes baseline wanders effectively without significant morphological distortion.

Detection of Premature Ventricular Contraction Using Discrete Wavelet Transform and Fuzzy Neural Network (이산 웨이블릿 변환과 퍼지 신경망을 이용한 조기심실수축 추출)

  • Jang, Hyoung-Jong;Lim, Joon-Shik
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.3
    • /
    • pp.451-459
    • /
    • 2009
  • This paper presents an approach to detect premature ventricular contraction(PVC) using discrete wavelet transform and fuzzy neural network. As the input of the algorithm, we use 14 coefficients of d3, d4, and d5, which are transformed by a discrete wavelet transform(DWT). This paper uses a neural network with weighted fuzzy membership functions(NEWFM) to diagnose PVC. The NEWFM discussed in this paper classifies a normal beat and a PVC beat. The size of the window of DWT is $-31/360{\sim}+32/360$ second(64 samples) whose center is the R wave. Using the seven records of the MIT-BIH arrhythmia database used in Shyu's paper, the classification performance of the proposed algorithm is 99.91%, which outperforms the 97.04% of Shyu's analysis. Using the forty records of the M1T-BIH arrhythmia database used in Inan's paper, the classification performance of the proposed algorithm is 98.01%, which outperforms 96.85% of Inan's one. The SE and SP of the proposed algorithm are 84.67% and 99.39%, which outperforms the 82.57% and 98.33%, respectively, of Inan's study.

  • PDF

A Study on the Detection of the Ventricular Fibrillation based on Wavelet Transform and Artificial Neural Network (웨이브렛과 신경망 기반의 심실 세동 검출 알고리즘에 관한 연구)

  • Song Mi-Hye;Park Ho-Dong;Lee Kyoung-Joung;Park Kwang-Li
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.780-785
    • /
    • 2004
  • In this paper, we proposed a ventricular fibrillation detection algorithm based on wavelet transform and artificial neural network. we selected RR intervals, the 6th and 7th wavelet coefficients(D6, D7) as features for classifying ventricular fibrillation. To evaluate the performance of the proposed algorithm, we compared the result of the proposed algorithm with that of fuzzy inference and fuzzy-neural network. MIT-BIH Arrhythmia database, Creighton University Ventricular Tachyarrhythmia database and MIH-BIH Malignant Ventricular Arrhythmia database were used as test and learning data. Among the algorithms, the proposed algorithm showed that the classification rate of normal and abnormal beat was sensitivity(%) of 96.10 and predictive positive value(%) of 99.07, and that of ventricular fibrillation was sensitivity(%) of 99.45. Finally. the proposed algorithm showed good performance compared to two other methods.

A study on an effective algorithms based on ECG signal (ECG 신호에 기반한 효과적인 알고리즘의 연구)

  • Lee, Hyun-Ju;Shin, Dong-Il;Shin, Dong-Kyoo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06c
    • /
    • pp.230-234
    • /
    • 2010
  • 심전도는 가장 일반화되어 있는 생체신호의 하나이다. 심전도를 측정하여 심장병의 유무와 여러 질환들을 예측하고 예방할 수 있다. 심전도 신호를 추출 하는 방법에는 여러 방법이 있는데, 본 논문에서 활용한 두 논문은 계층적인 분류로 HOS, HBF, HMH 세 방법으로 실험을 하였고, 적응가변형 윈도우를 이용한 R파 추출을 실행하였다. 두 논문은 공통적으로 MIT-BIH Arrhythmias Database(MIT-BIT 부정맥 데이터베이스)를 데이터로 실험 하였으며, 알고리즘으로는 SVM, Cross-Validation등을 사용하였다. 마지막으로 두 논문의 실험결과를 바탕으로 정확도를 높일 수 있는 효과적인 알고리즘 연구를 제안하였다.

  • PDF

Design of ECG Pattern Classification System Using Fuzzy-Neural Network (퍼지-뉴럴 네트워크를 이용한 심전도 패턴 분류시스템 설계)

  • 김민수;이승로;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.273-276
    • /
    • 2002
  • This paper has design of ECG pattern classification system using decision of fuzzy IF-THEN rules and neural network. each fuzzy IF-THEN rule in our classification system has antecedent lingustic values and a single consequent class. we use a fuzzy reasoning method based on a single winner rule in the classification phase. this paper in, the MIT/BIH arrhythmia database for the source of input signal is used in order to evaluate the performance of the proposed system. From the simulation results, we can effectively pattern classification by application of learned from neural networks.

  • PDF