• Title/Summary/Keyword: MHOS

Search Result 14, Processing Time 0.027 seconds

Fabrication of 6-superconducting layered HTS wire for high engineering critical current density

  • Kim, Gwantae;Ha, Hongsoo;Kim, Hosup;Oh, Sangsoo;Lee, Jaehun;Moon, Seunghyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.10-13
    • /
    • 2021
  • Recently, cable conductors composed of numerous coated conductors have been developed to transport huge current for large-scale applications, for example accelerators and fusion reactors. Various cable conductors such as CORC (Conductor on round core), Roebel Cable, and TSTC (Twisted stacked tape cable) have been designed and tested to apply for large-scale applications. But, these cable conductors cannot improve the engineering critical current density (Je) because they are made by simple stacking of coated conductors. In this study, multi-HTS (High temperature superconductor) layers on one substrate (MHOS) wire was fabricated to increase the engineering critical current density by using the exfoliation of superconducting layer from substrate and silver diffusion bonding method. By the repetition of these processes, the 10 m long 6-layer MHOS conductor was successfully fabricated without any intermediate layers like buffer or solder. 6-layer MHOS conductor exhibited a high critical current of 2,460A/12mm-w. and high engineering critical current density of 1,367A/mm2 at liquid nitrogen temperature.

Superconductivity of HTS REBCO coated conductors with multi-superconducting layers

  • Ye Rim, Lee; Kyu Jeong, Song;Gwan Tae, Kim;Sang Soo, Oh;Hong Soo, Ha
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.29-35
    • /
    • 2022
  • We fabricated MHOS (multi-HTS layers on one substrate) high-temperature superconducting (HTS) REBCO conductors using HTS REBCO coated conductor (CC) A-specimen, which induces an artificial magnetic flux pinning effect, and HTS REBCO CC B-specimen, that does not induce this effect. The superconducting magnetic properties of the fabricated MHOS conductors were examined by measuring their magnetic moment m(H) curves using a physical property measurement system (QD PPMS-14). The critical current density (Jc) characteristics of our four-layered MHOS HTS REBCO conductor specimens such as BAAB, BBBB, and AAAA were lower than those of their two-layered and three-layered counterparts. At a temperature T of 30 K the magnetic flux pinning physical indicator δ values (obtained from the relationship Jc ∝ H) of the three-layer ABA (δ = 0.35) and two-layer AB (δ = 0.43) specimens were found to be significantly lower than those of the four-layer ABBA (δ = 0.51), BAAB (δ = 0.60), AAAA (δ = 0.78) and BBBB (δ = 0.81) structures.

Opportunistic Scheduling with QoS Constraints for Multiclass Services HSUPA System

  • Liao, Dan;Li, Lemin
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.201-211
    • /
    • 2007
  • This paper focuses on the scheduling problem with the objective of maximizing system throughput, while guaranteeing long-term quality of service (QoS) constraints for non-realtime data users and short-term QoS constraints for realtime multimedia users in multiclass service high-speed uplink packet access (HSUPA) systems. After studying the feasible rate region for multiclass service HSUPA systems, we formulate this scheduling problem and propose a multi-constraints HSUPA opportunistic scheduling (MHOS) algorithm to solve this problem. The MHOS algorithm selects the optimal subset of users for transmission at each time slot to maximize system throughput, while guaranteeing the different constraints. The selection is made according to channel condition, feasible rate region, and user weights, which are adjusted by stochastic approximation algorithms to guarantee the different QoS constraints at different time scales. Simulation results show that the proposed MHOS algorithm guarantees QoS constraints, and achieves high system throughput.

  • PDF

Physicochemical Characteristics of Groundwater Salinization in the eastern aea of Cheju Island (제주도 동부지역 지하수의 염수화와 이화학적 특성)

  • Oh, Youn-Keun;Kim, Kyung-Hoo;Ryu, Seong-Pil
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.253-259
    • /
    • 2000
  • The purpose of this study is to investigate the physicochemical characteristics of salinization of groundwater at the estern area of Cheju island. For this purpose, the major ions of groundwater, spring water are analyzed. The concentration of $Cl^-$ and Na^++K^+$/ contained in the groundwater at near the coastline are higher than those at inland area away from the coastline. The water quality components of groundwater observed at this area can be classified into 4 types such as Na-Cl, $HCO_3, Na-Cl-HCO_3$ and Ca-HCO$_3$. The concentration ratio of $SO_4^1 to Cl^- is 0.1354(R^2=0.972)$ at this area. This value is very similar with Dittomer's ratio of 0.13. For Na^+, K^+, and Mg^{2+}/ versus Cl^-$, their ratios also show a significant relationship between sea water and groundwater in this area. From the chloride-bicarbonate ratio, it can be estimated that the intrusion distance of seawater from coastline to inland area is 2.8km at Onpyung-Nansan, Sangdo and Pyungdae areas, and 5.4km at Kosung-Susan area. The mixing ratio between seawater and fresh water by the intrusion of seawater is decreased with the distance toward inland from coastline. This ratio(fresh water : seawater) is 80:20 in spring water adjacent the coastlines, Onpyung area and 99.8:0.2 in the well at No.3 of Susan located at inland away from the coastline. The concentration of $Na^+$ observed at field is 25~45% lower than that theoretically calculated by this mixing ratio. Based on the data of EC, the equipotential line of 500$\mu$mhos/cm is located at 4~5km poing at Kosung-Susan area and 2.5km point at the other area. The equation of correlation between $Cl^-$ concentration and EC values is $Cl^-$=0.1927EC-16.683 for the area lower than 500 $\mu$mhos/cm and $Cl^-$=0.2773EC for the area beyond 500 $\mu$mhos/cm.

  • PDF

A Study on the Epilithic Algae in a stream drained from Hot Springs (온천 주변 소형하천에 서식하는 부착조류군집에 관한 연구)

  • 최환석;유춘만
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.131-136
    • /
    • 1998
  • Attached algal community and several physico-chemicai characters were investigated at Seokjong hot spring in Chollabukdo in February and in April, 1997. The results of physico-chemicai factors are as follows : water temperatures were varied from 6.5$^{\circ}$C to 32.0$^{\circ}$C; pH range was 6.9 to 7.7; The levels of electric conductivity were 105 $\mu$mhos/cm to 477 $\mu$mhos/cm; chemical oxygen demand(COD) range was 1.5 mg/l to 21.2 mg/l; ammonia concentration was 0.20 mg/l to 8.74 mg/l; nitrate concentrations were 0.36 mg/l to 2.43 mg/l; phosphate concentration was N.D. to 0.52 mg/l; sulfur concentration was 14.6 mg/l to 66.1 mg/l. Attacched algal species were identified. Totally, 63 taxa were classified and composed of 4 phylum, 4 class, 10 order, 17 family and 31 genera. The total biomass of attacched algae was $1.036 \times 10^{7}$ cells/l that composed of $5.39 \times 10^{6}$ cells/l of blue-green algae, $4.05 \times 10^{6}$ cells/l of diatom and $0.93 \times 10^{6}$ cells/l of green algae. The succession of dominant species was Synechocystis thermalis. This could be due to the thermal wastewaters. in biotic indices tests, the values of dominance index(DI) were 0.33 to 0.67 in winter, 0.18 to 0.68 in spring. The values of diversity index(H') were 1.44 to 2.69 in winter, 1.62 to 2.89 in spring. And the values of eveness index (J) were 0.31 to 0.61 in winter, 0.37 to 0.65 in spring.

  • PDF

Analysis of Electromagnetic Wave Shielding Effectiveness from Electrical Conductivity of Metallized Conductive Sheets (전도성 금속 피복재의 전기전도도에 의한 전자파 차폐효과 분석)

  • Kim, Yeong-Sik;Choe, Ik-Gwon;Kim, Seong-Su
    • Korean Journal of Materials Research
    • /
    • v.9 no.9
    • /
    • pp.913-918
    • /
    • 1999
  • As an alternative evaluation method of electromagnetic shielding properties, the material parameters are considered in determining the qualitative value of shielding effectiveness. The specimens are metallized nylon fabrics with the thickness of about 0.1 mm and the electrical conductivities in the range from 6.4$\times$10~2.4$\times$10(sup)5 mhos/m. On the basis of shielding theory, the shielding effectiveness (which is a sum of reflection loss and absorption loss) has been determined from the material parameters of the barrier sheets. For the conductive fabrics, the dominant shield mechanism is predicted to be reflection loss, which shows an increasing function of electrical conductivity. Comparing these theoretical value with the directly measured surface impedances, the error range is found to be within 10 dB, which demonstrates that the proposed material-parameters method can be a convenient way to determine the electromagnetic shielding properties.

  • PDF

R&D trends of high current REBCO conductor

  • Oh, Sang-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • So far, large-scale scientific devices such as nuclear fusion tokamaks and high energy circular accelerators were constructed using high-current conductors made of metallic superconducting wires. Recently, as REBCO superconducting wires usable in high magnetic fields have been developed by several companies, researchesto apply high current cable type REBCO conductors to next-generation large superconducting magnets were also started. High critical currents of several kA or more in high magnetic fields have been successfully demonstrated on test samples of REBCO cable conductors by several research groups. In this review article, the main features and properties of the representative high current REBCO conductors such as CORC(Conductor On Round Core), TSTC(Twisted Stacked-Tape Cable) and RACC(Roebel-Assembled Coated Conductor), which are currently being developed at abroad are briefly introduced. Research activities of high-current density REBCO MHOS(Multi HTS layers on One Substrate) conductor at KERI, whose structure is different from other cable type REBCO conductors are also shortly introduced.

Actual Uses and Water Qualities of Irrigation Water from Agricultural Reservoir and Pumping Station (관개용 저수지 및 양수장의 농업용수 공급량 및 수질)

  • Choi, Jin-Kyu;Han, Kang-Wan;Koo, Ja-Woong;Son, Jae-Gwon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.3
    • /
    • pp.205-212
    • /
    • 2001
  • Joongpyong reservoir and Guiseok pumping station were selected as the hydrologic monitoring sites for the water level gauging and amount of irrigation water use, and water samples were taken and analysed periodically. Rating curves were derived from the relations water level and discharge data, and water supply through culvert of the Joongpyong reservoir was $593,200m^3$ and irrigation water $2,913,000m^3$ from the Guiseok pumping station. Changes of stream water qualities such as water temperature, pH, EC, total nitrogen, total phosphorus were examined, pH was 6.98.1 lower than the criteria of agricultural water 6.0~8.5, total nitrogen $0.9{\sim}4.5mg\;L^{-1}$, total phosphorus $0.008{\sim}0.036mg\;L^{-1}$. The results from this study could be offered as a basic data for the irrigation plan and water quality management.

  • PDF

Post Milking Teat Dip Effect on Somatic Cell Count, Milk Production and Composition in Cows and Buffaloes

  • Shailja, Shailja;Singh, Mahendra
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.10
    • /
    • pp.1517-1522
    • /
    • 2002
  • The effect of post milking teat dipping on somatic cell count (SCC) of milk was determined in 20 Crossbred cows and 20 Murrah buffaloes selected from institute's herd. The animals were divided into two groups of 10 each. Animals of Group I (control) were teat washed with water before the milking while Group II animals were applied teat dipping solution after the completion of milking. The cows were milked 3 times a day while buffaloes were milked twice a day. The milk samples were collected from control and treated animals on day 0, 5, 10, 15, respectively. The milk samples were analyzed for milk constituents like fat, protein, lactose, chloride, IgG, NEFA, pH and EC and total and differential somatic cell counts. The changes in milk composition and somatic cell counts were significantly different (p<0.01) between the animals and between the breeds. However SCC, chloride content (p<0.05) and epithelial cells (p<0.01) varied during different days of study. The alterations in SCC, epithelial cells, TLC, lymphocyte, neutrophil, IgG, and protein content were significantly different (p<0.01) between control and treated groups. The pH, EC, protein, SCC, epithelial cells, lymphocyte and neutrophil cells of milk declined significantly (p<0.05) after the application of teat dipping, the respective values were 6.5 vs 6.40, 2.28 vs 2.37 mhos, 3.33 vs 4.04%, 1.00 vs $0.87{\times}10^5cells/ml$, 0.39 vs 0$0.34{\times}10^5cells/ml$, 0.36 vs $0.31{\times}1,000cells/ml$ and 0.17 vs $0.14{\times}1,000cells/ml$ in cows. However in buffaloes, epithelial cells, lymphocytes, neutrophils, EC and SCC declined (p<0.05) after application of teat dipping, the values being 0.37 vs $0.29{\times}10^5cells/ml$, 0.37 vs $0.25{\times}1,000cells/ml$, 0.14 vs $0.11{\times}1,000cells/ml$, 2.56 vs 2.37 mhos and 0.94 vs $0.73{\times}10^5cells/ml$, respectively. The study indicated that post milking teat dipping could be used as an effective method for the lowering of SCC in milk of crossbred cows and buffaloes.

Control of Microalgae Using a Porous Silicate Material, CellCaSi (규산질다공체 (CellCaSi)에 의한 미세조류 제어)

  • Lee, Seog-June;Yoon, Byung-Dae;Lee, Wook-Jae;Lee, Seung-Kyou;Choi, Long;Oh, Hee-Mock
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.2 s.90
    • /
    • pp.145-151
    • /
    • 2000
  • A porous silicate material named as CellCaSi was tested for the removal of microalgae in the water sample from a eutrophic pond. The effects of the CellCaSi on water qualities were investigated on the basis of both the particle size (under 1, 2,and 4 mm) and the added amount (0, 1, 5, and 10 g/l) of the CellCaSi. The removal efficiency of chlorophyll-a was highest at 79% by the addition of 10 g/l of the CellCaSi (under 1 mm) at day 3 after treatment. That is, the removal efficiency of chlorophyll-a by the CellCaSi increased with smaller particle size and more added amount. The dominant species, Chlorella ellipsoidea, was not changed by the addition of the CellCaSi, but the species number and standing crop of the algae diminished. Total nitrogen concentration was not changed much by the addition of the CellCaSi, whereas total phosphorus concentration was reduced. pH and turbidity were not changed by the addition of the CellCaSi, whereas conductivity showed a high correlation with the amount of added CellCaSi ($Y\;=\;29.2 {\cdot}X+306$, $r^2\;=0.984$). Therefore, it seems to be necessary to limit the amount of the CellCaSi under 6.6 g/1 in consideration of a registered maximum conductivity of $500\;{\mu}mhos/cm$ for raw and potable waters.

  • PDF