• Title/Summary/Keyword: MEMS Acceleration Sensor

Search Result 48, Processing Time 0.027 seconds

Ground Test and Performance Evaluation of Miniaturized AHRS for Small-Scale UAV (소형무인항공기를 위한 소형 경량 AHRS의 지상시험 및 성능 평가)

  • Roh, Min-Shik;Song, Jun-Beom;Song, Woo-Jin;Kang, Beom-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.2
    • /
    • pp.181-188
    • /
    • 2011
  • A small UAVs(Unmaned Aerial Vehicles) have limited by the payload capacity which requires miniaturization of a navigation system. In this paper, the performance of the lightweight and small sized AHRS(Attitude Heading Reference System), which is self-developed, is evaluated at low acceleration environment. The designed AHRS adopts the commercial low-cost MEMS sensors. A quaternion-based attitude calculation method, which eliminates singularity with relatively simple algebra, is used. In an attitude correction algorithm, the Kalman filter is used with accelerometers and magnetometers combined. The fabricated AHRS is also evaluated with reference to a COTS(Commercial Off-The-Shelf) AHRS which reports a number of successful applications to a small UAVs. The test results show that the measurements from the fabricated AHRS provide proper attitude output data with acceptable amount of differences(horizontal axis 0.5$^{\circ}$, vertical axis 1.5$^{\circ}$) in test environment.

Improving Finger-click Recognition of a Wearable Input Device

  • Soh, Byung-Seok;Kim, Yoon-Sang;Lee, Sang-Goog
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.72-75
    • /
    • 2004
  • In this paper, a finger-click recognition method is proposed to improve the recognition performance for finger-clicking of a wearable input device, called $SCURRY^{TM}$. The proposed method is composed of three parts including feature extraction part, valid click discrimination part, and cross-talk avoidance part. Two types of MEMS inertial sensors are embedded into the wearable input device to measure the angular velocity of a hand (hand movement) and the acceleration rates at the ends of fingers (finger-click motion). The experiment applied to the $SCURRY^{TM}$ device shows the improved stability and performance.

  • PDF

Application of Low Cost Acceleration-based Wireless Sensor Node for Structural Health Monitoring of Railroad Bridges (철도교량의 구조건전성모니터링을 위한 저가형 가속도기반 무선센서노드의 활용)

  • Hong, Dong-Soo;Ho, Duc-Duy;Park, Jae-Hyung;Kim, Jeong-Tae
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.77.1-77.1
    • /
    • 2010
  • 본 연구에서는 가속도기반 무선센서노드와 MEMS 가속도계 센서를 이용하여 철도교량의 구조건전성모니터링 기법들의 성능을 검토하였다. 이를 위해 다음과 같은 세 단계의 연구가 수행되었다. 첫째, 저가형 가속도기반 무선센서노드를 설계하였다. 둘째, 철도교량의 구조건전성모니터링을 위한 진동특성 및 건전성평가기법을 선정하였다. 마지막으로, 모형 강판형교에 대한 진동실험을 통해 개발된 가속도기반 무선센서노드의 성능을 평가하고 일련의 손상 시나리오를 대상으로 건전성평가 기법의 성능을 검토하였다. 시간영역 기법인 AR 모델과 주파수영역 기법인 파워스펙트럼 상관계수가 강판형교 구조손상 모니터링에 높은 정확도를 보였다.

  • PDF

A Study on Finger-click Recognition of a Wearable Input Device using Inertial Sensors (관성 센서를 이용한 착용형 공간 입력장치의 클릭 인식에 관한 연구)

  • Soh, Byung-Seok;Kim, Yoon-Sang;Lee, Sang-Goog
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.120-122
    • /
    • 2004
  • Wearable input device that can make free-space typewriting possible is introduced. We named this device as $SCURRY^{TM}$. To measure the angular velocity of hand and the acceleration rates at the ends of fingers, we buried MEMS inertial sensors in this keyboard. We processed sensor signals to get the information on hand movement and finger-click motion. With this signal processing, apparent finger movements were depicted over the virtual keyboard shown on output device of a target computing system. In this paper, a finger-click recognition method is proposed to improve the recognition performance for finger clicking of $SCURRY^{TM}$. The proposed method is composed of three parts including feature extraction part, valid click part, and cross-talk avoidance part. The experiments were conducted to verify the effectiveness and efficiency of the proposed algorithms.

  • PDF

Design of a Compact GPS/MEMS IMU Integrated Navigation Receiver Module for High Dynamic Environment (고기동 환경에 적용 가능한 소형 GPS/MEMS IMU 통합항법 수신모듈 설계)

  • Jeong, Koo-yong;Park, Dae-young;Kim, Seong-min;Lee, Jong-hyuk
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.1
    • /
    • pp.68-77
    • /
    • 2021
  • In this paper, a GPS/MEMS IMU integrated navigation receiver module capable of operating in a high dynamic environment is designed and fabricated, and the results is confirmed. The designed module is composed of RF receiver unit, inertial measurement unit, signal processing unit, correlator, and navigation S/W. The RF receiver performs the functions of low noise amplification, frequency conversion, filtering, and automatic gain control. The inertial measurement unit collects measurement data from a MEMS class IMU applied with a 3-axis gyroscope, accelerometer, and geomagnetic sensor. In addition, it provides an interface to transmit to the navigation S/W. The signal processing unit and the correlator is implemented with FPGA logic to perform filtering and corrrelation value calculation. Navigation S/W is implemented using the internal CPU of the FPGA. The size of the manufactured module is 95.0×85.0×.12.5mm, the weight is 110g, and the navigation accuracy performance within the specification is confirmed in an environment of 1200m/s and acceleration of 10g.

Measurements of pedestrian's ioad using smartphones

  • Pan, Ziye;Chen, Jun
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.771-777
    • /
    • 2017
  • The applications of smartphones or other portable smart devices have dramatically changed people's lifestyle. Researchers have been investigating useage of smartphones for structural health monitoring, earthquake monitoring, vibration measurement and human posture recognition. Their results indicate a great potential of smartphones for measuring pedestrian-induced loads like walking, jumping and bouncing. Smartphone can catch the device's motion trail, which provides with a new method for pedestrain load measurement. Therefore, this study carried out a series of experiments to verify the application of the smartphone for measuring human-induced load. Shaking table tests were first conducted in order to compare the smartphones' measurements with the real input signals in both time and frequency domains. It is found that selected smartphones have a satisfied accuracy when measuring harmonic signals of low frequencies. Then, motion capture technology in conjunction with force plates were adopted in the second-stage experiment. The smartphone is used to record the acceleration of center-of-mass of a person. The human-induced loads are then reconstructed by a biomechanical model. Experimental results demonstrate that the loads measured by smartphone are good for bouncing and jumping, and reasonable for walking.

Fabrication of AlN piezoelectric micro power generator suitable with CMOS process and its characteristics (CMOS 공정에 적합한 AlN 압전 마이크로 발전기의 제작 및 특성)

  • Chung, Gwiy-Sang;Lee, Byung-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.209-213
    • /
    • 2010
  • This paper describes the fabrication and characteristics of AlN piezoelectric MPG(micro power generator). The micro energy harvester was fabricated to convert ambient vibration energy to electrical power as a AlN piezoelectric cantilever with Si proof-mass. To be compatible with CMOS process, AlN thin film was grown at low temperature by RF magnetron sputtering and micro power generators were fabricated by MEMS technologies. X-ray diffraction pattern proved that the grown AlN film had highly(002) orientation with low value of FWHM(full width at the half maximum, $\theta=0.276^{\circ}$) in the rocking curve around(002) reflections. The implemented harvester showed the $198.5\;{\mu}m$ highest membrane displacement and generated 6.4 nW of electrical power to $80\;k{\Omega}$ resistive load with $22.6\;mV_{rms}$ voltage from 1.0 G acceleration at its resonant frequency of 389 Hz. From these results, the AlN piezoelectric MPG will be possible to suitable with the batch process and confirm the possibility for power supply in portable, mobile and wearable microsystems.

Development of Earthquake Early Warning System nearby Epicenter based on P-wave Multiple Detection (진원지 인근 지진 조기 경보를 위한 선착 P파 다중 탐지 시스템 개발)

  • Lee, Taehee;Noh, Jinseok;Hong, Seungseo;Kim, YoungSeok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.107-114
    • /
    • 2019
  • In this paper, the P-wave multiple detection system for the fast and accurate earthquake early warning nearby the epicenter was developed. The developed systems were installed in five selected public buildings for the validation. During the monitoring, a magnitude 2.3 earthquake occurred in Pohang on 26 September 2019. P-wave initial detection algorithms were operated in three out of four systems installed in Pohang area and recorded as seismic events. At the nearest station, 5.5 km from the epicenter, P-wave signal was detected 1.2 seconds after the earthquake, and S-wave was reached 1.02 seconds after the P-wave reached, providing some alarm time. The maximum accelerations recorded in three different stations were 6.28 gal, 6.1 gal, and 5.3 gal, respectively. The alarm algorithm did not work, due to the high threshold of the maximum ground acceleration (25.1 gal) to operate it. If continuous monitoring and analysis are to be carried out in the future, the developed system could use a highly effective earthquake warning system suitable for the domestic situation.