• Title/Summary/Keyword: MEMS(Micro-Electro-Mechanical Systems)

Search Result 146, Processing Time 0.034 seconds

Position Control of Electrostatic Microactuator (정전형 마이크로 액튜에이터의 정밀위치제어)

  • 김승한;성우경;이효정
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1063-1066
    • /
    • 1995
  • This paper presents a precition control of an electrostatic microactuator. For the generation of sufficient electrostatic force, a donse comb-type electrostatic microactuator is designed and manufactureed via MEMS (micro-electro-mechanical systems) process. The nonlinear plant and the linear plant of the microactuator are established through the comparison of experimental results and simulation results. A feedforward controller is designed via MATLAB simulation using the inverse function of the nonlinear plant. the experiment for the precise position tracking control is undertaken to show the control efficiency of the proposed controller.

  • PDF

Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System (MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토)

  • Chae, Bong-Geon;Kim, Tae-Gyu;Lee, Jong-Kwang;Kang, Suk-joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.455-462
    • /
    • 2016
  • Output Characteristics of the spaceborn image sensor such as infrared(IR) sensor are varied according to time elapses and sensor repetition on/off operation. As a result, the quality of IR sensor image is decreased. Therefore, spaceborne image sensor require a periodic calibration using a black body system by correcting a non-uniformity of the sensor. In this paper, we proposed a MEMS-based black body system that can implement the high temperature uniformity at various standard temperatures ranging from low to high temperature and easily estimate the representative surface temperature. In addition, it has advantages lightweight, low-power and high accuracy. The feasibility of the proposed MEMS-based black body system was verified through the thermal analysis.

Recent research trends on Bio-MEMS (Bio-MEMS분야의 최근 연구동향)

  • Park, Se-Kwang;Yang, Joo-Ran
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.259-270
    • /
    • 2010
  • MEMS(micro electro mechanical systems) is a technology for the manufacture hyperfine structure, as a micro-sensor and a driving device, by a variety of materials such as silicon and polymer. Many study for utilizing the MEMS applications have been performed in variety of fields, such as light devices, high frequency equipments, bio-technology, energy applications and other applications. Especially, the field of Bio-MEMS related with bio-technology is very attractive, because it have the potential technology for the miniaturization of the medical diagnosis system. Bio-MEMS, the compound word formed from the words 'Bio-technology' and 'MEMS', is hyperfine devices to analyze biological signals in vitro or in vivo. It is extending the range of its application area, by combination with nano-technology(NT), Information Technology(IT). The LOC(lab-on-a-chip) in Bio-MEMS, the comprehensive measurement system combined with Micro fluidic systems, bio-sensors and bio-materials, is the representative technology for the miniaturization of the medical diagnosis system. Therefore, many researchers around the world are performing research on this area. In this paper, the application, development and market trends of Bio-MEMS are investigated.

Measurement of mechanical properties of SU-8 thin film by tensile testing (단축 인장에 의한 SU-8박막의 기계적 물성 측정)

  • 백동천;박태상;이순복;이낙규
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.23-26
    • /
    • 2004
  • Thin film is one of the most general structures used in micro-electro-mechanical systems (MEMS). To measure the mechanical properties of SU-8 film, tensile testing was adopted which offers not only elastic modulus but also yield strength and plastic deformation by load-displacement curve. Tensile testing system was constructed with linear guided servo motor for actuation, load cell for force measurement and dual microscope for strain measurement.

  • PDF

A Study on the Optimum Design for LTCC Micro-Reformer: (Performance Evaluation of Various Flow Channel Structures ('LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구: (다양한 채널구조에 따른 성능변화 고찰)')

  • Chung Chan-Hwa;Oh Jeong-Hoon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.551-552
    • /
    • 2006
  • The miniature fuel cells have emerged as a promising power source for applications such as cellular phones, small digital devices, and autonomous sensors to embedded monitors or to micro-electro mechanical system (MEMS) devices. Several chemicals run candidate at a fuel in those systems, such as hydrogen. methanol, ethanol, acetic acid, and di-methyl ether (DME). Among them, hydrogen shows most efficient fuel performance. However, there are some difficulties in practical application for portable power sources. Therefore, more recently, there have been many efforts for development of micro-reformer to operate highly efficient micro fuel cells with liquid fuels such as methanol, ethanol, and DME In our experiments, we have integrated a micro-fuel processor system using low temperature co-fired ceramics (LTCC) materials. Our integrated micro-fuel processor system is containing embedded heaters, cavities, and 3D structures of micro- channels within LTCC layers for embedding catalysts (cf. Figs. 1 and 2). In the micro-channels of LTCC, we have loaded $CuO/ZnO/Al_2O_3$ catalysts using several different coating methods such as powder packing or spraying, dipping, and washing of catalyst slurry.

  • PDF

Fabrication and evaluation of a micro heat flux sensor using thermopile (열전대를 이용한 미세 열유속 센서의 제작 및 평가)

  • Kim Jung-Hoon;Kim Bum-Seok;Cho Hyung-Hee;Kim Yong-Jun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1210-1213
    • /
    • 2005
  • Micro heat flux sensor is used in various industries to measure heat flux. In this study, a micro heat flux sensor is fabricated using the MEMS (Micro Electro Mechanical Systems) techniques. The fabricated sensor is composed in thermopile for sensor and SU-8 for thermal resistance layer. The new method of fabrication SU-8 is proposed in this study. The sensitivity is $44\;\mu{V/(W/cm^2)}$ at steady state and Reynolds number is 91322.

  • PDF

Mechanically Modulated Actuators and Branched Finger Detectors for Nano-Precision MEMS Applications

  • Cho, Young-Ho;Lee, Won-Chul;Han, Ki-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.39.1-39
    • /
    • 2002
  • We present nanoactuators and nanodetectors for high-precision Micro Electro Mechanical System (MEMS) applications. Major technical difficulties in the high-precision MEMS are arising from the fabrication uncertainty and electrical noise problems. In this paper, we present high-precision actuators and detectors, overcoming the technical limitations placed by the conventional MEMS technology. For the nano-precision actuation, we present a nonlinearly modulated digital actuator (NMDA). NMDA composed of a digital microactuator and a nonlinear micromechanical modulator. The nonlinear micromechanical modulator is intended to purify the actuation errors in the stroke of the digital a...

  • PDF

Ramp loading scratch 방법에 의한 실리콘 기반 박막들의 파손 특성에 관한 연구

  • 이재원;정구현;김대은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.140-140
    • /
    • 2004
  • 마이크로 기술을 대변하는 Micro-Electro-Mechanical-Systems (MEMS)와 반도체, 각종 micro-sensor 및 actuator 등은 실리콘 위에 박막 코팅한 재료를 주로 사용하고 있다. 따라서 1 Um 이하의 박막코팅에 의해 원하는 성능을 얻으려는 시도가 널리 진행되고 있다 Hard Disk Drive (HDD)의 Head-Disk Interface (HDI)와 MEMS 접촉면에서는 발생하는 마찰 및 마멸에 대한 문제 등은 중요한 고려대상이다. 특히 코팅 층의 표면 파손 현상은 코팅 층의 파손 특성과 코팅 층과 기판 사이의 결합상태가 큰 영향을 미친다.(중략)

  • PDF

Design of a Camera Calibration System in a Smart Thermo-Sensor Based Network (스마트 열센서 네트워크의 카메라 미세조정을 위한 시스템 구축)

  • Moon Sang-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.924-926
    • /
    • 2006
  • Sensor networks are an emerging area of mobile computing. Networked sensors represent a new design paradigm enabled by advances in micro electro-mechanical systems (MEMS) and low power technology. Created with integrated circuit (IC) technology and combined with computational logic, these 'smart' sensors have the benefit of small size, low cost and power consumption, and, the capability to perform on-board computation. Though this recent technological innovation has shown a significant promise in many application domains, it has also exposed several technical limitations that must be improved. In this paper, we discuss the system deploy issues for infrared thermo sensor camera calibration.

  • PDF

Vibration based damage localization using MEMS on a suspension bridge model

  • Domaneschi, Marco;Limongelli, Maria Pina;Martinelli, Luca
    • Smart Structures and Systems
    • /
    • v.12 no.6
    • /
    • pp.679-694
    • /
    • 2013
  • In this paper the application of the Interpolation Damage Detection Method to the numerical model of a suspension bridge instrumented with a network of Micro-Electro-Mechanical System sensors is presented. The method, which, in its present formulation, belongs to Level II damage identification method, can identify the presence and the location of damage from responses recorded on the structure before and after a seismic damaging event. The application of the method does not require knowledge of the modal properties of the structure nor a numerical model of it. Emphasis is placed herein on the influence of recorded signals noise on the reliability of the results given by the Interpolation Damage Detection Method. The response of a suspension bridge to seismic excitation is computed from a numerical model and artificially corrupted with random noise characteristic of two families of Micro-Electro-Mechanical System accelerometers. The reliability of the results is checked for different damage scenarios.