• 제목/요약/키워드: MEMS(Micro Electro-Mechanical Systems)

검색결과 146건 처리시간 0.032초

정전형 마이크로 액튜에이터의 정밀위치제어 (Position Control of Electrostatic Microactuator)

  • 김승한;성우경;이효정
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 1995
  • This paper presents a precition control of an electrostatic microactuator. For the generation of sufficient electrostatic force, a donse comb-type electrostatic microactuator is designed and manufactureed via MEMS (micro-electro-mechanical systems) process. The nonlinear plant and the linear plant of the microactuator are established through the comparison of experimental results and simulation results. A feedforward controller is designed via MATLAB simulation using the inverse function of the nonlinear plant. the experiment for the precise position tracking control is undertaken to show the control efficiency of the proposed controller.

  • PDF

MEMS 기반 흑체 시스템의 온도 균일도 및 추정 정확도의 수치 해석적 검토 (Numerical Investigation of Temperature Uniformity and Estimation Accuracy for MEMS-based Black Body System)

  • 채봉건;김태규;이종광;강석주;오현웅
    • 한국항공우주학회지
    • /
    • 제44권5호
    • /
    • pp.455-462
    • /
    • 2016
  • 적외선 검출기와 같은 우주용 영상센서는 작동 유무 및 시간경과에 따라 센서의 응답특성이 변하기 때문에 영상품질이 저하된다. 이러한 영상센서의 비균일 응답특성을 보정하기 위하여 궤도상에서 보정용 흑체시스템을 이용하여 주기적인 보정을 실시 할 수 있도록 해야 한다. 본 논문에서는 저온에서 고온에 이르는 다양한 기준온도에서의 높은 온도균일도 확보 및 흑체의 대표표면온도 추정이 용이하고, 초경량, 저전력, 고정밀도의 흑체 시스템을 구현하기 위해 MEMS(Micro Electro Mechanical Systems)기반의 흑체시스템을 제안하였으며, 열해석을 통해 성능을 입증하였다.

Bio-MEMS분야의 최근 연구동향 (Recent research trends on Bio-MEMS)

  • 박세광;양주란
    • 센서학회지
    • /
    • 제19권4호
    • /
    • pp.259-270
    • /
    • 2010
  • MEMS(micro electro mechanical systems) is a technology for the manufacture hyperfine structure, as a micro-sensor and a driving device, by a variety of materials such as silicon and polymer. Many study for utilizing the MEMS applications have been performed in variety of fields, such as light devices, high frequency equipments, bio-technology, energy applications and other applications. Especially, the field of Bio-MEMS related with bio-technology is very attractive, because it have the potential technology for the miniaturization of the medical diagnosis system. Bio-MEMS, the compound word formed from the words 'Bio-technology' and 'MEMS', is hyperfine devices to analyze biological signals in vitro or in vivo. It is extending the range of its application area, by combination with nano-technology(NT), Information Technology(IT). The LOC(lab-on-a-chip) in Bio-MEMS, the comprehensive measurement system combined with Micro fluidic systems, bio-sensors and bio-materials, is the representative technology for the miniaturization of the medical diagnosis system. Therefore, many researchers around the world are performing research on this area. In this paper, the application, development and market trends of Bio-MEMS are investigated.

단축 인장에 의한 SU-8박막의 기계적 물성 측정 (Measurement of mechanical properties of SU-8 thin film by tensile testing)

  • 백동천;박태상;이순복;이낙규
    • 반도체디스플레이기술학회지
    • /
    • 제3권2호
    • /
    • pp.23-26
    • /
    • 2004
  • Thin film is one of the most general structures used in micro-electro-mechanical systems (MEMS). To measure the mechanical properties of SU-8 film, tensile testing was adopted which offers not only elastic modulus but also yield strength and plastic deformation by load-displacement curve. Tensile testing system was constructed with linear guided servo motor for actuation, load cell for force measurement and dual microscope for strain measurement.

  • PDF

'LTCC를 소재로 하는 마이크로 리포머의 최적 설계에 관한 연구: (다양한 채널구조에 따른 성능변화 고찰)' (A Study on the Optimum Design for LTCC Micro-Reformer: (Performance Evaluation of Various Flow Channel Structures)

  • 정찬화;오정훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.551-552
    • /
    • 2006
  • The miniature fuel cells have emerged as a promising power source for applications such as cellular phones, small digital devices, and autonomous sensors to embedded monitors or to micro-electro mechanical system (MEMS) devices. Several chemicals run candidate at a fuel in those systems, such as hydrogen. methanol, ethanol, acetic acid, and di-methyl ether (DME). Among them, hydrogen shows most efficient fuel performance. However, there are some difficulties in practical application for portable power sources. Therefore, more recently, there have been many efforts for development of micro-reformer to operate highly efficient micro fuel cells with liquid fuels such as methanol, ethanol, and DME In our experiments, we have integrated a micro-fuel processor system using low temperature co-fired ceramics (LTCC) materials. Our integrated micro-fuel processor system is containing embedded heaters, cavities, and 3D structures of micro- channels within LTCC layers for embedding catalysts (cf. Figs. 1 and 2). In the micro-channels of LTCC, we have loaded $CuO/ZnO/Al_2O_3$ catalysts using several different coating methods such as powder packing or spraying, dipping, and washing of catalyst slurry.

  • PDF

열전대를 이용한 미세 열유속 센서의 제작 및 평가 (Fabrication and evaluation of a micro heat flux sensor using thermopile)

  • 김정훈;김범석;조형희;김용준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1210-1213
    • /
    • 2005
  • Micro heat flux sensor is used in various industries to measure heat flux. In this study, a micro heat flux sensor is fabricated using the MEMS (Micro Electro Mechanical Systems) techniques. The fabricated sensor is composed in thermopile for sensor and SU-8 for thermal resistance layer. The new method of fabrication SU-8 is proposed in this study. The sensitivity is $44\;\mu{V/(W/cm^2)}$ at steady state and Reynolds number is 91322.

  • PDF

Mechanically Modulated Actuators and Branched Finger Detectors for Nano-Precision MEMS Applications

  • Cho, Young-Ho;Lee, Won-Chul;Han, Ki-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.39.1-39
    • /
    • 2002
  • We present nanoactuators and nanodetectors for high-precision Micro Electro Mechanical System (MEMS) applications. Major technical difficulties in the high-precision MEMS are arising from the fabrication uncertainty and electrical noise problems. In this paper, we present high-precision actuators and detectors, overcoming the technical limitations placed by the conventional MEMS technology. For the nano-precision actuation, we present a nonlinearly modulated digital actuator (NMDA). NMDA composed of a digital microactuator and a nonlinear micromechanical modulator. The nonlinear micromechanical modulator is intended to purify the actuation errors in the stroke of the digital a...

  • PDF

Ramp loading scratch 방법에 의한 실리콘 기반 박막들의 파손 특성에 관한 연구

  • 이재원;정구현;김대은
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.140-140
    • /
    • 2004
  • 마이크로 기술을 대변하는 Micro-Electro-Mechanical-Systems (MEMS)와 반도체, 각종 micro-sensor 및 actuator 등은 실리콘 위에 박막 코팅한 재료를 주로 사용하고 있다. 따라서 1 Um 이하의 박막코팅에 의해 원하는 성능을 얻으려는 시도가 널리 진행되고 있다 Hard Disk Drive (HDD)의 Head-Disk Interface (HDI)와 MEMS 접촉면에서는 발생하는 마찰 및 마멸에 대한 문제 등은 중요한 고려대상이다. 특히 코팅 층의 표면 파손 현상은 코팅 층의 파손 특성과 코팅 층과 기판 사이의 결합상태가 큰 영향을 미친다.(중략)

  • PDF

스마트 열센서 네트워크의 카메라 미세조정을 위한 시스템 구축 (Design of a Camera Calibration System in a Smart Thermo-Sensor Based Network)

  • 문상국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.924-926
    • /
    • 2006
  • 저전력 집적회로 기술과 MEMS (micro electro-mechanical systems) 기술이 융합된 산물인 스마트 센서는 작은 크기, 저비용, 저전력의 특성을 가지고, 그와 더불어 임베디드 어플리케이션에 사용되기에 적합하므로 이동 환경 컴퓨팅 분야에서 주목을 받고 있다. 이 센서들이 이동 통신에 적용되면 어플리케이션의 특성에 따라 인간의 접촉이 쉽지 않은 곳과 원격 통신이 가능하다는 장점이 있다. 이러한 혁명적인 원격 네트워크 기술로 인하여 활동적인 연구자들에게 엄청난 연구의 장이 열린 것이다. 본 논문에서는 그 중 한가지의 어플리케이션인 열센서 카메라에 대한 응용 분야로, 적외선 열센서 카메라에 대한 미세 조정을 위한 시스템 구축 방안에 대하여 논의한다.

  • PDF

Vibration based damage localization using MEMS on a suspension bridge model

  • Domaneschi, Marco;Limongelli, Maria Pina;Martinelli, Luca
    • Smart Structures and Systems
    • /
    • 제12권6호
    • /
    • pp.679-694
    • /
    • 2013
  • In this paper the application of the Interpolation Damage Detection Method to the numerical model of a suspension bridge instrumented with a network of Micro-Electro-Mechanical System sensors is presented. The method, which, in its present formulation, belongs to Level II damage identification method, can identify the presence and the location of damage from responses recorded on the structure before and after a seismic damaging event. The application of the method does not require knowledge of the modal properties of the structure nor a numerical model of it. Emphasis is placed herein on the influence of recorded signals noise on the reliability of the results given by the Interpolation Damage Detection Method. The response of a suspension bridge to seismic excitation is computed from a numerical model and artificially corrupted with random noise characteristic of two families of Micro-Electro-Mechanical System accelerometers. The reliability of the results is checked for different damage scenarios.