• 제목/요약/키워드: MEG

검색결과 137건 처리시간 0.026초

진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작 (A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

시각추적과제의 뇌자도 : 예비실험 (A Pilot MEG Study During A Visual Search Task)

  • 김성훈;이상건;김광기
    • Annals of Clinical Neurophysiology
    • /
    • 제8권1호
    • /
    • pp.44-47
    • /
    • 2006
  • Background: The present study used magnetoencephalography (MEG) to investigate the neural substrates for modified version of Treisman's visual search task. Methods: Two volunteers who gave informed consent participated MEG experiment. One was 27- year old male and another was 24-year-old female. All were right handed. Experiment were performed using a 306-channel biomagnetometer (Neuromag LTD). There were three task conditions in this experiment. The first was searching an open circle among seven closed circles (open condition). The second was searching a closed circle among seven uni-directionally open circles (closed condition). And the third was searching a closed circle among seven eight-directionally open circles (random (closed) condition). In one run, participants performed one task condition so there were three runs in one session of experiment. During one session, 128 trials were performed during every three runs. One participant underwent one session of experiment. The participant pressed button when they found targets. Magnetic source localization images were generated using software programs that allowed for interactive identification of a common set of fiduciary points in the MRI and MEG coordinate frames. Results: In each participant we can found activations of anterior cingulate, primary visual and association cortices, posterior parietal cortex and brain areas in the vicinity of thalamus. Conclusions: we could find activations corresponding to anterior and posterior visual attention systems.

  • PDF

외관(外關)(TE5).협계(俠谿)(GB43) 자침이 SQUID로 측정한 뇌 청각영역의 뇌자도(腦磁圖) 변화에 미치는 영향 (A SQUID MEG Study on the Auditory Primary Response induced by Acupuncture on TE5 (Waiguan).GB43 (Xiaxi))

  • 최찬헌;라기웅;장경선;나창수
    • Korean Journal of Acupuncture
    • /
    • 제23권4호
    • /
    • pp.135-145
    • /
    • 2006
  • Objectives and Methods : Using the 2-channel DROS SQUID (Korea Research Institute of Standards of Science, 1999), the present study was carried out to record changes elicited in the auditory cortex by acupuncture stimulus on right TE5 (Waiguan) and GB43 (Xiaxi). Needle-retention stimulation of TE5 and GB43 were done for acquiring the brain activities changed by acupuncture. Acupoint TE5 and GB43 is known to be effective for the treatment of ear-related disease, such as deafness and tinnitus, and to be suspected to be related to the auditory cortex. Auditory evoked magnetic fields were recorded hem the left hemisphere of five subjects, in response to contralateral ear stimulation by irregularly spaced 170 msec long 1kHz tone busts (Korea Research Institute of Standards of Science) Results and Conclusions : The result as follows. The latency and amplitude of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on TE5 were 4msec and 9.2 fT, respectively, which were slower and smaller than those of no-acupuncture condition. The latency and amplitude of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on GB43 were 7.2 msec and 1.6 fT, respectively, which were slower and larger than those of no-acupuncture condition. The latency of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on GB43 condition was slower than that of TE5 acupuncture condition.

  • PDF

2-HP-β-시클로덱스트린과 메글루민을 이용한 란소프라졸의 포접화합물 제조 및 평가 (Preparation and Evaluation of Inclusion Complex of Lansoprazole with 2-HP-β-Cyclodextrin and Meglumine)

  • 이정우;김정수;장혜진;이계원;지웅길
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권4호
    • /
    • pp.269-274
    • /
    • 2004
  • To enhance the solubility and stability of lansoprazole (LAN), new proton pump inhibitor, we were prepared various molar ratio of inclusion complex with $2-hydroxypropyl-{\beta}-cyclodextrin$ (HPCD) and organic alkali agent, meglumine (MEG). Inclusion complex formation of LAN with HPCD was investigated by Differential Scanning Calorimetry and X-ray diffractometry. The aqueous solubilities of inclusion complexes, and the stabilities of 1:4 and 1:5 inclusion complexes in aqueous solutions containing different concentrations of MEG were examined. The stability of 1:5 LAN-HPCD inclusion complex containing MEG, which was equaled to amount of LAN, was performed in 0.9% NaCl and 5% dextrose solution. The formation of inclusion complex of LAN with HPCD was $A_L$ type and the molar ratio of complex was 1:1. The stability constant was $41.557\;M^{-1}$. As molar ratio of LAN to HPCD was increased, solubility of inclusion complex was increased. 1:5 LAN-HPCD inclusion complex was more stable than 1:4 LAN-HPCD inclusion complex. And as contained MEG amount in LAN solution was increased, stability of 1:4 and 1:5 LAN-HPCD inclusion complexes was improved. Also stability of 1:5 LAN-HPCD-MEG inclusion complex in 0.9% NaCl solution and 5% dextrose solution was similar to it in water at room temperature, but it was unstable at $40^{\circ}C$.

An Improved Multiresolution Technique to Reconstruct Magnetoencephalography(MEG) Source Distribution

  • Im, Chang-Hwan;An, Kwang-Ok;Jung, Hyun-Kyo;Lee, Yong-Ho;Kwon, Hyuk-Chan
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.385-389
    • /
    • 2003
  • In this paper, an improved technique for multiresolutive reconstruction of magnetoencephalography (MEG) source distribution is proposed. Using the proposed technique, focal solution with higher energy density can be reconstructed. Moreover, the proposed approach is very easy to implement compared to conventional ones. The usefulness of the proposed technique is verified by the application to a real brain model.

Source Localization Techniques for Magnetoencephalography (MEG)

  • Kwang-Ok An;Chang-Hwan Im;Hyun-Kyo Jung;Yong-Ho Lee;Hyuk-Chan Kwon
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.53-58
    • /
    • 2002
  • In this paper, various aspects in magnetoencephalography (MEG) source localization are studied. To minimize the errors in experimental data, an approximation technique using a polynomial function is proposed. The simulation shows that the proposed technique yields more accurate results. To improve the convergence characteristics in the optimization algorithm, a hybrid algorithm of evolution strategy and sensitivity analysis is applied to the neuromagnetic inverse problem. The effectiveness of the hybrid algorithm is verified by comparison with conventional algorithms. In addition, an artificial neural network (ANN) is applied to find an initial source location quickly and accurately. The simulation indicates that the proposed technique yields more accurate results effectively.

  • PDF

하드웨어 효율적인 동적 커패시턴스 보상 구현을 위한 고속 영상 압축 및 화소별 스위칭 기법 (Fast Image Compression and Pixel-wise Switching Technique for Hardware Efficient Implementation of Dynamic Capacitance Compensation)

  • 최준환;송원석;최혁
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권8호
    • /
    • pp.616-622
    • /
    • 2009
  • 동적 커패시턴스 제어(DCC) 기술로 인하여 액정 디스플레이 장치의 약점 중 하나였던 응답 시간 성능이 크게 개선되었다. 하지만 DCC는 계산 과정에서 이전 프레임 영상의 실시간 저장 및 출력을 반복해야 하며, 이 과정에 활용되는 고속 메모리는 HD 고해상도 디스플레이 제작에 있어 높은 하드웨어적 부담 및 비용 상승의 원인이 된다. 본 연구에서는 복잡도가 낮은 고속 영상 압축 기법인 변형 지수-골룸 (MEG) 코딩을 제안하며, 이를 통해 DCC 기술에 요구되는 메모리의 양을 크게 줄일 수 있다. 또한 본 연구에서는 화소별 DCC 스위칭 기법을 제안하여 압축 오차가 최종 액정 디스플레이 영상의 시각 품질에 악영향을 미치지 않도록 하였다. 제안된 방식을 이용해 DCC 처리용 메모리의 크기를 1/3로 줄여도 최종 영상의 시각 품질 손상이 거의 없음을 실험을 통해 확인할 수 있었다.

뇌파/뇌자도 전류원 국지화의 공간분해능 향상을 위한 독립성분분석 기반의 부분공간 탐색 알고리즘 (An ICA-Based Subspace Scanning Algorithm to Enhance Spatial Resolution of EEG/MEG Source Localization)

  • 정영진;권기운;임창환
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권6호
    • /
    • pp.456-463
    • /
    • 2010
  • In the present study, we proposed a new subspace scanning algorithm to enhance the spatial resolution of electroencephalography (EEG) and magnetoencephalography(MEG) source localization. Subspace scanning algorithms, represented by the multiple signal classification (MUSIC) algorithm and the first principal vector (FINE) algorithm, have been widely used to localize asynchronous multiple dipolar sources in human cerebral cortex. The conventional MUSIC algorithm used principal component analysis (PCA) to extract the noise vector subspace, thereby having difficulty in discriminating two or more closely-spaced cortical sources. The FINE algorithm addressed the problem by using only a part of the noise vector subspace, but there was no golden rule to determine the number of noise vectors. In the present work, we estimated a non-orthogonal signal vector set using independent component analysis (ICA) instead of using PCA and performed the source scanning process in the signal vector subspace, not in the noise vector subspace. Realistic 2D and 3D computer simulations, which compared the spatial resolutions of various algorithms under different noise levels, showed that the proposed ICA-MUSIC algorithm has the highest spatial resolution, suggesting that it can be a useful tool for practical EEG/MEG source localization.

모발 및 피부 개선의 오존화 올리브 오일 생산에 대한 안전성에 관한 연구 (The Study On Safety of Olive Oil Production Ozonized of Hair and Skin Improvement)

  • 박선이
    • 한국응용과학기술학회지
    • /
    • 제32권3호
    • /
    • pp.583-587
    • /
    • 2015
  • 본 연구는 부작용 없고 문제성 두피 및 피부개선 등에 효과가 좋지만 온도와 습도에 민감한 오존크림을 일정한 과산화물가와 방전관 내구성 안정적인 생산을 위한시스템을 개발하고자 한다. 더 나아가 올리브 오일과 오존과 반응시켜 제조하는 기술에 적용하고자 한다. 오존화 올리브 오일의 과산화물가가 1200 meg/kg 넘을 경우 미생물 살균에는 좋으나 두피 및 피부에 과민반응을 보이기 때문에 위험을 최소화하여 생산되도록 하는 것이 본 연구 및 실험의 목적이다. 그리고 안정된 생산을 위하여 제조 장치중에 방전관의 내구성도 실험하였다. 그 실험 결과 오존화 올리브오일의 과산화물가가 1300 meg/kg 로 적정하게 측정되었고, 방전관도 안정된 결과를 보였다.

협계혈(GB43) 자침시 침시술 방법에 따른 SQUID MEG 신호의 변화 관찰 (SQUID MEG Responses of the Human Auditory Cortex Generated by Acupuncture on GB43(Xiaxi))

  • 전용석;장경선;김진근;최찬헌
    • 동의생리병리학회지
    • /
    • 제19권4호
    • /
    • pp.1032-1038
    • /
    • 2005
  • Using the 2-channel DROS SQUID (Korea Research Institute of Standards of Science, 1999), the present study was carried out to record changes elicited in the auditory cortex by acupuncture stimulus (right GB43, Xiaxi). Needle-retention and manual needle-twitching stimulation of GB43 and SP1 were done for acquiring the brain activities changed by acupuncture. Acupoint GB43 is known to be effective for the treatment of ear-related disease, such as deafness and tinnitus, and to be suspected to be related to the auditory cortex. Auditory evoked magnetic fields were recorded from the left hemisphere of five or four subjects, in response to contralateral ear stimulation by irregularly spaced 170msec long 1kHz tone busts (Korea Research Institute of Standards of Science). The result as follows The latency and amplitude of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on GB43 were 7.2msec and 1.617, respectively, which were slower and larger than those of no-acupuncture condition. The amplitude of SQUID MEG responses at the human auditory cortex changed by needle-twitching condition on GB43 was 13.517, which was larger than that of no-acupuncture condition. The change in SP1 following GB43 needle-twitching condition were not observed in latency. The amplitude changed by needle-twitching condition on SP1 was 12.2fT, which was not significant. These results suggested that auditory cortex can be affected by acupuncture stimulus, though not specific or significant because of small number of subjects.