• Title/Summary/Keyword: MDF

Search Result 251, Processing Time 0.026 seconds

Toxicity Evaluation of the Combustion Products from Synthetic Wood as Internal Finish (건축물 내부 마감재인 합성목재별 연소가스 독성평가)

  • Kim, Jong-Buk;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.7-18
    • /
    • 2016
  • This study evaluated the toxicity of the burning gas from the synthetic wood products used in housings or warehouses. The combustion products of five materials, viz. impregnated laminated board, MDF, Douglas fir plywood, core plywood, and Lauan retardant, were analyzed using SEM, FTIR and a Cone Calorimeter. For the Lauan retardant, 256,965 ppm of carbon dioxide ($CO_2$) and 1,475 ppm of sulfur dioxide ($SO_2$) were measured, which are 2.5 times and 3.6 times as high as their lethal concentrations of 100,000 ppm and 400 ppm, respectively. For the impregnated laminated board, 1,569 ppm of nitrogen dioxide ($NO_2$) was measured, which is 6 times as high as its lethal concentration of 250 ppm. For MDF, 795 ppm of ammonia ($NH_3$) was measured, which is higher than its lethal concentration of 750 ppm. As a result, most internal-finishes generated toxic combustion products at levels higher than their lethal concentrations, which underlines the importance of the selection and manufacturing of internal-finish materials.

Measurement of Molecular Weights of Melamine-Urea-Formaldehyde Resins and Their Influences to Properties of Medium Density Fiberboards

  • Jeong, Bora;Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.913-922
    • /
    • 2016
  • This study attempted to measure molecular weight (MW) of melamine-urea-formaldehyde (MUF) resins prepared by two different synthesis methods: the one-step MUF resins were synthesized in one batch procedure, while the two-step MUF resins were prepared by a physical mixing of urea-formaldehyde (UF) resin with melamine-formaldehyde (MF) resin that had been synthesized in a separate procedure. The properties of medium density fiberboard (MDF) panels bonded with two types of MUF resins were also investigated. MWs of these MUF resins were measured using gel permeation chromatography (GPC). In addition, this study measured the MWs of one-step MUF resin during its synthesis procedure. The performance of two types of MUF resins was evaluated by determining properties of MDF panels prepared in laboratory. As the synthesis procedure progressed, both number average MW ($M_n$) and weight average MW ($M_w$) of one-step MUF resin gradually increased, while the polydispersity index (PDI) decreased. And low Mw species of the resin predominantly decreased as the synthesis step progressed. The one-step MUF resin showed greater $M_n$ and $M_w$ than those of the two-step ones even though the PDI values of both resins were very similar each other. As expected, the one-step MUF resin resulted in better properties of MDF panels than those of two-step resins. In particular, the one-step MUF resin provided better internal bond (IB) strength and thickness swelling (TS) with MDF panels than those of two-step ones, indicating better water resistance of the one-step resin. These results suggest that the preparation method of MUF resins have a great impact on the MW and final panel properties.

Comparison of Moisture Absorption/Desorption Properties of Carbonized Boards Made from Wood-Based Panels (목질판상재로 제조된 탄화보드의 흡방습 성능 비교)

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.424-429
    • /
    • 2016
  • In this study, the carbonized boards were manufactured from different types of wood-based panel and then their moisture absorption/desorption properties were investigated and compared. The carbonization temperature was maximum $600^{\circ}C$ with 2 h maintains. Test results showed higher absorption/desorption capacity on carbonized plywood than carbonized MDF, PB, and OSB, respectively. However, carbonized MDF, OSB, and plywood had similar absorption/desorption rate per hour. It means carbonized OSB and plywood can transfer moisture into deeper side and then possibly hold more amount of water. Based on SEM images, carbonized OSB and plywood showed more like wood structure, while carbonized MDF and PB had only wood fiber or/and chunk of wood fragments. Therefore, original wood structure may affect moisture absorption/desorption capacity. In order to manufacture high moisture absorbing/desorbing carbonized board, wood structure should be considered and then carbonized.

Application of Field and Laboratory Emission Cell (FLEC) to Determine Formaldehyde and VOCs Emissions from Wood-Based Composites

  • Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.24-37
    • /
    • 2007
  • The Korean Ministry of Environment started controlling indoor air quality (IAQ) in 2004 through the introduction of a law regulating the use of pollutant emitting building materials. The use of materials with formaldehyde emission levels above $1.25 mg/m^2{\cdot}h$ (JIS A 1901, small chamber method) has been prohibited. This level is equivalent to the $E_2$ grade ($>5.0mg/{\ell}$) of the desiccator method (JIS A 1460). However, the $20{\ell}$ small chamber method requires a 7-day test time to obtain the formaldehyde and volatile organic compound (VOC) emission results from solid building interior materials. As a approach to significantly reduce the test time, the field and laboratory emission cell (FLEC) has been proposed in Europe with a total test time less than one hour. This paper assesses the reproducibility of testing formaldehyde and TVOC emissions from wood-based composites such as medium density fiberboard (MDF), laminate flooring, and engineered flooring using three methods: desiccator, perforator and FLEC. According to the desiccator and perforator standards, the formaldehyde emission level of each flooring was ${\le}E_1$ grade. The formaldehyde emission of MDF was $3.48 mg/{\ell}$ by the desiccator method and 8.57 g/100 g by the perforator method. To determine the formaldehyde emission, the peak areas of each wood-based composite were calculated from aldehyde chromatograms obtained using the FLEC method. Formaldehyde, acetaldehyde, propionaldehyde, butyraldehyde and benzaldehyde were detected as aldehyde compounds. The experimental results indicated that MDF emitted chloroform, benzene, trichloroethylene, toluene, ethylbenzene, m,p-xy-lene, styrene, and o-xylene. MDF emitted significantly greater amounts of VOCs than the floorings did.

Real-Time Implementation of FDAF and MDF Algorithms for Adaptive Noise Cancellation (적응잡음제거를 위한 FDAF와 MDF 알고리즘의 실시간 구현)

  • Joh Woo-Guen;Chong Won-Yong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.7-14
    • /
    • 2000
  • Recently, the technologies of adaptive noise cancellation(ANC) are developed fast and widely due to the highly sophisticated digital signal processing algorithms and the high-speed communication networks and devices. But, thousand numbers of the adaptive filter taps are required to obtain the satisfying results in the fields of the adaptive noise cancellation and echo cancellation. In the paper, performance comparisons based on the real-time processing between frequency domain adaptive filter(FDAF) and multi-delay frequency domain adaptive filter(MDF) are carried. Those algorithms provide us with the reductions of the computational burdens and the increase of the convergence rate for the lengthy Fill adaptive filters. The time delay due to the long taps of FDAF can be reduced by adopting the MDF algorithms. The conventional ANC and cross talks ANC using FDAF are implemented on the dSP ACE 1103 real-time signal processing board.

  • PDF

Characteristics of Initiation and Termination of Muscle Contraction in Early Hemiparetic Wrists: Analysis of Median Frequency (초기 편마비 환자에서 손목 근수축 개시 및 종료의 특성: 중앙주파수 분석)

  • Chung, Yi-Jung;Cho, Sang-Hyun;Kwon, Oh-Yun;Lee, Young-Hee
    • Physical Therapy Korea
    • /
    • v.13 no.1
    • /
    • pp.38-46
    • /
    • 2006
  • The purposes of this study were to investigate the median frequency (MDF) between initiation and termination of muscle contraction through surface electromyographic (sEMG) analysis and to propose the basis of clinical treatment for movement problems in early hemiparetic upper limbs. Thirteen patients who had stroke with onset less than 3 months prior to the study and seven control subjects participated in the study. The median frequency in initiation and termination of muscle contraction was recorded from wrist flexor and extensor muscles using the sEMG, with 3 second beeper signals, during maximal isometric wrist flexion and extension. Flexion and extension must be done as quickly and forcefully as possible. The results of the study were as follows: 1. The MDF of the onset and offset sections were significantly lower on the paretic than the nonparetic and control sides. 2. The MDF of the offset section significantly decreased on the paretic and nonparetic sides. Consequently, this study showed that the lowering of the MDF was due to the hemiparetic wrist motor impairment and muscle weakness. These results are also related to Fugl-Meyer motor assessment (FMA) scores in hemiparetic upper limbs. This study also suggests that since muscle weakness of early stroke patients affects the functional decrease of upper limbs, further studies must focus on the treatment to improve muscle agility and muscle fiber recruitment efficiency that can induce the functional recovery correlated to motor control.

  • PDF

Properties of Woodceramics Made from MDF (MDF로 제조된 우드세라믹의 성질)

  • Oh, Seung-Won;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.115-120
    • /
    • 2002
  • Woodceramics are new porous carbon materials obtained by burning wood or woody materials impregnated with thermosetting resin in a vacuum furnace. In this paper, the change of dimensions and bending strength of woodceramics which were made from medium density fiberboard have been investigated to examination the possibility of utilization as a woodceramics materials. 1) An increasing rate of dimension in impregnated board increased with increasing resin impregnation rate. And increasing rate of thickness was higher than that of length. 2) When the resin impregnation rate increased, the bending strength of impregnated board had a tendency to increase. 3) The rates of weight loss, length and thickness reduction of woodceramics showed a slight increase with increased burning temperature. 4) The density of woodceramics showed a increase from at 500℃ till at 800℃ with increasing burning temperature but decrease at 1,000℃ 5) When the burning temperature increased, the bending strength of woodceramics had a tendency to increase.

Development of Program for Ignition Temperature and Its Applications (발화온도 산출 프로그램 개발 및 적용)

  • Park, Won-Hee;Cho, Youngmim;Kwon, Tae-Soom
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.4
    • /
    • pp.243-250
    • /
    • 2017
  • A fire phenomenon of a solid such as wood involves a phenomenon in which solid is heated from the outside and the gas generated through the thermal pyrolysis process of the material is burnt. The thermal pyrolysis phenomenon of the solid is a phenomenon in which the amount of energy incident from the outside, the amount of heat dissipation of the solid material, the heat transfer between the solid material and the surroundings including the amount of heat transfer to the air adjacent to the solid surface, and the fraction of oxygen in the air. In this paper, we calculate the required ignition temperature to simulate the fire phenomenon as simple as possible. By using cone calorimeter, the ignition time was measured by variously controlling the heat flux flowing into the wood specimen by using various wood specimens. The user friendly program is developed for calculation of the ignition temperature. Five different woods such as low density MDF, high density MDF, plywood, douglas fir and PB with various thickness are considered. The ignition temperatures suggested in this paper can be used for fire propagation analysis for woods.