• 제목/요약/키워드: MCNP

검색결과 353건 처리시간 0.025초

TET2MCNP: A Conversion Program to Implement Tetrahedral-mesh Models in MCNP

  • Han, Min Cheol;Yeom, Yeon Soo;Nguyen, Thang Tat;Choi, Chansoo;Lee, Hyun Su;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.389-394
    • /
    • 2016
  • Background: Tetrahedral-mesh geometries can be used in the MCNP code, but the MCNP code accepts only the geometry in the Abaqus input file format; hence, the existing tetrahedral-mesh models first need to be converted to the Abacus input file format to be used in the MCNP code. In the present study, we developed a simple but useful computer program, TET2MCNP, for converting TetGen-generated tetrahedral-mesh models to the Abacus input file format. Materials and Methods: TET2MCNP is written in C++ and contains two components: one for converting a TetGen output file to the Abacus input file and the other for the reverse conversion process. The TET2MCP program also produces an MCNP input file. Further, the program provides some MCNP-specific functions: the maximum number of elements (i.e., tetrahedrons) per part can be limited, and the material density of each element can be transferred to the MCNP input file. Results and Discussion: To test the developed program, two tetrahedral-mesh models were generated using TetGen and converted to the Abaqus input file format using TET2MCNP. Subsequently, the converted files were used in the MCNP code to calculate the object- and organ-averaged absorbed dose in the sphere and phantom, respectively. The results show that the converted models provide, within statistical uncertainties, identical dose values to those obtained using the PHITS code, which uses the original tetrahedral-mesh models produced by the TetGen program. The results show that the developed program can successfully convert TetGen tetrahedral-mesh models to Abacus input files. Conclusion: In the present study, we have developed a computer program, TET2MCNP, which can be used to convert TetGen-generated tetrahedral-mesh models to the Abaqus input file format for use in the MCNP code. We believe this program will be used by many MCNP users for implementing complex tetrahedral-mesh models, including computational human phantoms, in the MCNP code.

XSDRN, ONEDANT및 MCNP에 의한 사용후 핵연료 용기의 중성자 차폐 해석 (Neutron Shielding Analysis for a Spent Fuel Container Using XSDRN, ONEDANT and MCNP Codes)

  • 김교윤;이태영;하정우;김종경
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.46-55
    • /
    • 1989
  • 사용후 핵연료 용기에 대한 중성자 차폐 해석을 위하여 각분할법 코드인 ONEDANT 및 XSDRN과 몬테칼로 코드인 MCNP를 사용하였다. ORIGEN-S로 부터 결정된 선원항이 ONEDANT및 XSDRN에 각각 이용되었고, MCNP에 입력되는 선원항으로는 ONEDANT와 XSDRN으로 부터 계산된 중성자 스펙트럼을 사용하였으며, 중성자 에너지군은 27군과 10군으로 하였다. 감손 우라늄을 중성자 차폐 물질로 사용하였을 경우, MCNP의 계산 결과에 대하여 ONEDANT의 계산결과는 10%, XSDRN은 20% 이내에서 접근하였다. 또한, MCNP의 계산 결과에 의하면, 고려한 중성자 차폐물질의 성능은 감손 우라늄, 철, 그리고 납의 순으로 좋은 것으로 나타났다.

  • PDF

ANISN-MCNP 코드를 이용한 월성2호기 반응도제어기구 방사선흐름해석

  • 김용일;진영권;김교윤
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.269-274
    • /
    • 1996
  • 월성원자력발전소 2호기와 같은 CANDU 6형 원자로의 반응도제어기구 설치대에는 여러 반응도제어기구가 삽입되기때문에 원자로심으로부터의 방사선흐름현상으로 인한 방사선피폭이 예상될 수 있는 위치이다. 좁고 긴 반응도제어기구 도관에서의 방사선 흐름으로 인한 반응도제어기구 설치대에서의 방사선량을 예측하기 위해 몬테 칼로 MCNP 코드를 1차원 각분할법 코드인 ANISN과 연계하여 사용하였다. 월성원자력2호기의 상단차폐해석을 위한 ANISN 계산, 도관의 방사선흐름을 평가하기 위한 MCNP 계산, 그리고 반응도제어기구 설치대에서의 방사선량율 평가를 위한 MCNP 계산등 3단계 계산 기법의 적응이 시도되었다.

  • PDF

MCNP 기반의 CBCT 전산모사 시스템 개발 (Development of an MCNP-Based Cone-Beam CT Simulator)

  • 임창휘;조민국;한종철;윤한빈;윤승만;정민호;김호경
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.351-359
    • /
    • 2009
  • 원추형 빔 단층촬영 시스템의 효과적인 모사를 위하여 상용 몬테칼로 코드인 MCNP를 기반으로 한 전산모사 시뮬레이터를 개발하였다. 기본적으로 Visual $C++^{(R)}$를 이용하여 제작하였으며, 모델의 시각화를 위해 $OpenGL^{(R)}$ 라이브러리를 이용하여 개발하였다. 컴퓨터 단층촬영 시뮬레이션 수행을 위한 입력파일의 생성과 MCNP를 이용한 시뮬레이션 실행, 그리고 투과영상 생성과 단층영상 재구성을 수행할 수 있는 기능을 구현하였다. 개발한 시뮬레이터의 검증을 위하여 콘트라스트 팬텀(contrast phantom)에 대해 실험과 시뮬레이션을 수행하였다. 산란 엑스선, 영상센서의 잡음 및 픽셀 결함에 의한 structured noise 등을 시뮬레이션에서 고려하지 못했기 때문에 두 결과가 정확하게 일치하지는 않았으나, 매우 유사한 비교 결과를 얻을 수 있었다. 본 연구를 통해 개발한 MCNP 기반의 CBCT 전산모사 시스템은 CBCT의 이해, 실제 시스템의 설계 및 제작시에 도움을 줄 것으로 기대된다.

몬테칼로모사를 이용한 고리 1 호기 감시?슐에서의 핵반응단면적 및 고속중성자플루언스 계산

  • 김종오;김종경
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.45-52
    • /
    • 1996
  • 고리 1 호기 원자로 감시?슐에서의 고속중성자 플루언스를 계산하기 위하여 MCNP코드로 3차원 모델링을 하였다. 중성자선원은 MCNP에 의해 계산된 핵연료봉출력분포를 사용하였고 원자로심부터 원자로 압력용기 밖까지 1 MeV이상의 중성자를 수송시켰다. 감시?슐은 실제의 같은 크기로 모델링하였고 감시?슐안의 시편은 원자로 압력용기와 같은 재질의 직육면체로 가정하였다. 그리고 MCNP에 의해 감시시편내의 방사화 시료의 핵반응단면적을 계산하였다. 또한 MCNP에 의해 이론적으로 계산된 감시?슐에서 중성자 플루언스와 기존의 감시시험에서 측정된 포화방사능으로 부터 계산된 실험적 감시?슐 중성자 플루언스를 비교하였다. 이론적 ?슐플루언스와 실험적 ?슐플루언스의 비는 대체로 1.0에서 크게 벗어나지 않았으나 감시시험과 시편에 따라 크게 벗어나는 경우도 있었다. MCNP에 의한 유효반응단면적의 계산방법이 기존의 방법보다 모델링 및 계산의 불확실성을 최소화 할 수 있으므로 이번 연구에서 고려하지 못한 원자로심의 연소도를 고려한다면 매우 신뢰성이 높은 결과를 얻을 수 있다.

  • PDF

COMPARISON OF CANDU DUPIC PHYSICS CODES WITH MCNP

  • Gyuhong Roh;Park, Hangbok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.65-70
    • /
    • 1997
  • Computational benchmark calculations have been performed for CANDU DUPIC fuel lattice and core using a Monte Carlo code MCNP-4B with ENDF/B-V library. The eigenvalues of the DUPIC fuel lattice have been predicted by an integral transport code WIMS-AECL using ENDF/B-V library for different burnup steps and lattice conditions. The comparison has shown that the eigenvalues match those of MCNP-4B within 0.20% $\Delta$k difference between WIMS-AECL and MCNP-4B results. The calculation of a 2-dimensional CANDU core loaded with DUPIC fuel has shown that the eigenvalue predicted by a diffusion code RFSP using lattice parameters generated by WIMS-AECL matches that of MCNP-4B within 0.12%Δk and the largest bundle power prediction error is around 7.2%.

  • PDF

Application of a new neutronics/thermal-hydraulics coupled code for steady state analysis of light water reactors

  • Safavi, Amir;Esteki, Mohammad Hossein;Mirvakili, Seyed Mohammad;Arani, Mehdi Khaki
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1603-1610
    • /
    • 2020
  • Due to ever-growing advancements in computers and relatively easy access to them, many efforts have been made to develop high-fidelity, high-performance, multi-physics tools, which play a crucial role in the design and operation of nuclear reactors. For this purpose in this study, the neutronic Monte Carlo and thermal-hydraulic sub-channel codes entitled MCNP and COBRA-EN, respectively, were applied for external coupling with each other. The coupled code was validated by code-to-code comparison with the internal couplings between MCNP5 and SUBCHANFLOW as well as MCNP6 and CTF. The simulation results of all code systems were in good agreement with each other. Then, as the second problem, the core of the VVER-1000 v446 reactor was simulated by the MCNP4C/COBRA-EN coupled code to measure the capability of the developed code to calculate the neutronic and thermohydraulic parameters of real and industrial cases. The simulation results of VVER-1000 core were compared with FSAR and another numerical solution of this benchmark. The obtained results showed that the ability of the MCNP4C/COBRA-EN code for estimating the neutronic and thermohydraulic parameters was very satisfactory.

Determination of buildup factors for some human tissues using both MCNP5 and Phy-X / PSD

  • Mohammad M. Alda'ajeh;J.M. Sharaf;H.H. Saleh;Mefleh S. Hamideen
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4426-4430
    • /
    • 2023
  • In this article, Exposure Buildup Factor(EBF) and the Energy Absorption Buildup Factor(EABF) have been determined for blood, brain, and muscle using the Monte Carlo method which is represented by MCNP5 codes and compared with geometric progression(G-P) fitting method which is represented by Phy-X/PSD online platform. The novelty of the present work is used an energy source of less than 0.1 MeV to determine buildup factors using MCNP5 and using Phy-X/PSD for some human tissues. thus, the energy range used in this case study was 0.06-3 MeV for penetration depths covered 0.5-3 MFP. Results of MCNP5 and Phy-X/PSD are validated against reference values of water that were reported at ANS-6.4.3. present results of EABFs and EBFs for the previously mentioned human tissues appeared good agreement between MCNP5 in comparison with Phy-X/PSD, whereas, the maximum average relative deviation did not exceed 2.37%. results of our article can be used in different medical applications, such as brachytherapy, radiotherapy, and diagnostics.

월성 1호기 MCNP/ORIGEN-2 모델 검증 및 예비 선원항 계산 (Verification of MCNP/ORIGEN-2 Model and Preliminary Radiation Source Term Evaluation of Wolsung Unit 1)

  • 노경호;하창주
    • 방사성폐기물학회지
    • /
    • 제13권1호
    • /
    • pp.21-34
    • /
    • 2015
  • 원자력발전소 해체를 준비하기 위해서는 해체대상 발전소에 대한 선원항 평가가 선행되어야 한다. 해체전략 수립단계에서 선원항 평가 결과를 토대로 해체 폐기물을 분류하고 비용평가를 수행한다. 본 연구에서는 월성 1호기의 예비 선원항 계산을 수행할 수 있도록 MCNP/ORIGEN-2 모델의 타당성 평가를 수행하였다. 연소도가 다른 핵연료 다발의 악티나이드 계열과 핵분열 생성물의 핵종 수밀도는 싱글 채널 모델을 이용하여 MCNPX 코드로 연소 계산하여 구하였다. 선원항의 정확도에 영향을 미치는 두가지 요인에 대해 조사하였다. 첫번째 요인으로 선원항 계산에 영향을 미치는 중성자 스펙트럼을 MCNP로 계산하여 해당 핵종의 1군 미시 핵단면적에 반영하였다. 중성자 스펙트럼이 반영된 라이브러리로 계산한 선원항과 ORIGEN-2 코드 package에 내장된 library (CANDUNAU.LIB)로 구한 선원항을 비교하였다. 두번째 요인으로 선원항에 대한 출력이력의 영향을 조사하였다. 해체 폐기물의 저준위 폐기물 처분 가능성을 살펴보기 위해, 2010년도 교체된 압력관, 칼란드리아관과 기존 칼란드리아 동체에 대하여 중성자 스펙트럼을 반영한 library를 적용하여 MCNP/ORIGEN-2로 선원항 평가 계산을 수행하였다.