• Title/Summary/Keyword: MCCB

Search Result 93, Processing Time 0.02 seconds

Analysis and Design of Separated Permanent-Magnet Actuator for 225AF Molded Case Circuit Breaker

  • Park, Hyeon-Jeong;Kim, So-Hyun;Ro, Jong-Suk;Jung, Hyun-Kyo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.487-490
    • /
    • 2014
  • The conventional motor-driven MCCB (molded-case circuit breaker) is not only large in size, but also inefficient in performance. To solve these problems, this paper suggests SPMA (separate permanent-magnet actuator), a novel magnetic actuator. In this paper, SPMA is designed for a 225AF MCCB and compared to a conventional motor-driven MCCB and to an EMFA (electro-magnetic force driving actuator)-type MCCB.

Design of Electromagnetic Force driving Actuator for Molded Case Circuit Breaker (배선용 차단기(MCCB) 구동용 전자석 조작기(EMFA) 설계)

  • Kim, Rae-Eun;Kang, Jong-Ho;Kwak, Sang-Yeop;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.29-31
    • /
    • 2008
  • Recent years have witnessed that the Korean government prompts the 'Power IT' enterprise to combine electric Power industry with information technology (IT). Especially, in a move to shore up the distribution automation system, the necessity for remote control of molded case circuit breaker (MCCB) is getting more and more important. In this paper, we aimed to propose a remote-controlled MCCB of which the driving device is substituted to electrical equipment for mechanical parts. Driving device of MCCB was designed with the Electromagnetic Force driving Actuator (EMFA). Electromagnetic force and dynamic characteristics of the designed EMFA are analyzed using 2-D finite element method (FEM).

  • PDF

A Basis Study for Life Time Test of MCCB (배선용 차단기 수명평가를 위한 기초 연구)

  • Seo, Jung-Youl;Shin, Hee-Sang;Kim, Oh-Hwan;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.439-441
    • /
    • 2009
  • Recently, load circuits and components of customer are various. Therefore failures of ELB(Earth Leakage Breaker) and MCCB(Molded case circuit breakers) are more frequent. Lite time of MCCB even if there is same units differ from environment, condition of operation. FEMCA is a efficiency method of system operation or maintenance for system reliability. We study on FMECA procedures and method. In this paper, we focused on FMECA application to MCCB life time test.

  • PDF

Effect on Molded Case Circuit Breaker of Harmonic Current (고조파 전류가 배선용차단기에 미치는 영향)

  • Yoo, Jae-Geun;Choi, Myung-Il;Park, Chee-Hyun;Son, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • This paper analyze the operating characteristic of MCCB due to the synthesize harmonic current. Four types of MCCBs, divided by the type of operation system and a principle of operation, tested with 200[%] of rated current. The test result nuisance tripping did not occur but the time delay characteristic of the hydraulic magnetic type MCCB is appeared. From the place where the synthesize harmonic content is high it is good the hydraulic magnetic type MCCB not to use.

New Arc Chamber to Improve Breaking Capacity (차단용량 향상을 위한 신소호 구조)

  • Park, Jin-Young;Cho, Hea-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.321-326
    • /
    • 2012
  • The mechanism unit, arc chamber and trip unit are imperative components of MCCB which will decide the level of performance of MCCB. Among them, Arc chamber unit is used for extinguishing arc rapidly of fault current and induce the arc inside of grid. At that time inducing arc will split into parts and cooled rapidly so the arc would disappear. This paper suggests new arc chamber unit to improve arc extinguishing performance with optimum design and are applied to actual products based on the results.

Methods for Increasing the Interrupting Performance by Changing the Shape of Are Chamber in Molded Case Circuit Breaker (배선용 차단기의 소호부의 형상 변화를 통한 차단 성능 향상 방법)

  • Cho, Sung-Hoon;Lee, Han-Ju;Yoon, Jae-Hun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.28-28
    • /
    • 2010
  • The higher the short circuit currents, the faster the interruption takes place. For increasing the interrupting performance of the MCCB, it is important to design optimally the adjustable tripping device, the open /shut mechanism, and the arc quenching room in the MCCB. This paper is focused on understanding the interrupting performance, more specifically of the grid and the fix contact, based on the shape of the arc quenching room in the current MCCB.

  • PDF

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

A Numerical Study on Temperature Fields in MCCB (MCCB 내의 온도장에 대한 수치적 연구)

  • Park, S.K.;Lee, Jong-Chul;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.145-150
    • /
    • 2003
  • In this paper we have studied the characteristics of temperature fields in a Molded Case Circuit Breaker (MCCB). A switch and a trip device are arranged in narrow space of the MCCB. Thus, thermal factors have been risen to important problem. The temperature rise means an energy loss and it becomes the reason of fatal fault in devices. Also, the temperature rise on the connection and the contact parts is regulated up to $115^{\circ}C$ and $105^{\circ}C$, respectively. Therefore, a study for preventing the temperature rise should be investigated. A numerical analysis method that has confidence might be preceded for this purpose. In order to verify the confidence of temperature field analysis, the results of the numerical analysis are compared with those of experimental one for the same model. Comparison results show a qualitatively good agreement within ${\pm}5%$ errors.

  • PDF

Context-aware Multimedia Framework based on Software Agent Platforms

  • Hendry;Seongjoon Pak;Yumi Sohn;Kim, Munchurl
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.253-255
    • /
    • 2003
  • We address an integrated multimedia framework based on a software agent platform for context-aware multimedia computing. We adopt the FIPA (Foundation for Intelligent Physical Agents) platform which provides agent communications and management mechanisms. In order to express context information, we use MPEG-21 metadata for describing user characteristics and usage environment. We encapsulate such context information as a FIPA message to be delivered between agents. Based on context information, appropriate multimedia content delivery becomes possible. We present our system implementation with a use case scenario and show that our proposed framework is effective for context-aware multimedia computing so that personalization of multimedia consumption can be possible.

  • PDF

Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact (MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Cho, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.54-60
    • /
    • 2008
  • In this study, damage characteristics of MCCB and terminal block due to poor contact were analyzed, and various poor contact detection techniques were suggested. Firstly, the detection techniques using thermocouple and infrared thermal camera were analyzed respectively. Also, thermo-cap during poor contact detected abnormal status effectively by changing its color, and the detection system using an odor detector and odor capsules was analyzed. Lastly, poor contact detection screw was made using characteristics of fusible alloy, and we applied the poor contact detection screw to terminal block. The above methods could prevent electrical fire caused by poor contact effectively if they are used properly.