• Title/Summary/Keyword: MCA

Search Result 465, Processing Time 0.052 seconds

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Analysis on Ischemic Cerebrovascular of Middle Age and Oldest-Old Age by Using Magnetic Resonance Imaging (자기공명영상을 이용한 중년 및 초고령의 허혈성 뇌혈관 호발 부위에 대한 분석)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.391-396
    • /
    • 2012
  • The purpose of this study was to present basic research data to utilize magnetic resonance imaging (MRI) with analyzing intracerebral regional distributions of ischemic cerebrovascular disease of middle aged and oldest-old aged people. We retrospectively analyzed middle-aged group (average age of 44.2 year-old, 43 males, 26 females) and oldest-old aged group (average age of 84.7 year-old, 58 males, 71 females) who taken MRI screening for ischemic cerebrovascular disease from May 2006 year to January 2008 year. The intracerebral vascular were classified into 8 vessels, which anterior communication artery (ACoA), posterior communication artery (PCoA), anterior cerebral artery (ACA), middle cerebral artery (MCA), posterior cerebral artery (PCA), internal carotid artery (ICA), common carotid artery(CCA), and basilar artery (BA). The result of middle-aged group showed that more ischemic cerebrovascular diseases appeared in men than women, and it affected in MCA mostly. In oldest-old aged group, ischemic cerebrovascular diseases occurred evenly spaced in intracerebral region of right, left, and both vessels, and women have more than men. For men, the most occurred in ICA and for women the most occurred in MCA. Specially middle-aged group in men showed that more ischemic cerebrovascular diseases in MCA appeared than oldest-old aged group in men. It is suggested that the analysis on ischemic cerebrovascular could be helpful in the clinical diagnosis and treatment.

Prediction of Urban Land Cover Change Using Multilayer Perceptron and Markov Chain Analysis (다층 퍼셉트론(MLP)과 마코프 체인 분석(MCA)을 이용한 도심지 피복 변화 예측)

  • Bhang, Kon Joon;Sarker, Tanni;Lee, Jin-Duk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.85-94
    • /
    • 2018
  • The change of land covers in 2026 was prediceted based on the change of urbanization in 1996, 2006 and 2016 in Seoul and surrounding areas in this study. Landsat images were used as the basic data, and MLP (Multilayer Perceptron) and MCA (Markov Chain Analysis) were integrated for future prediction for the study area. The land cover transition potentials were calculated by setting up sub-models in MLP and the driving factors of land cover transition from 1996 to 2006 and transition probabilities were calculated using MCA to generate the land cover map of 2016. This was compared to the land cover map of 2016 from Landsat. MLP and MCA were verified and the future land covers of 2026 were predicted using the land cover map from Landsat in 2006 and 2016. As a result, it was predicted that the major land cover changes from 1996 to 2006 were from Barren Land and Grass Land to Builtup Area, and the same trend of transition will be remained for 2026. This study is meaningful in that it is applied for the first time to predict the future coating change in Seoul and surrounding areas by the MLP-MCA method.

Synthesis and Preliminary Evaluation of $9-(4-[^{18}F]Fluoro-3-hydroxymethylbutyl)$ Guanine $([^{18}F]FHBG)$ in HSV1-tk Gene Transduced Hepatoma Cell (9-(4-$[^{18}F]Fluoro-3-hydroxymethylbutyl)$guanine $([^{18}F]FHBG)$의 합성과 헤르페스 단순 바이러스 티미딘 키나아제 이입 간암 세포주에서의 기초 연구)

  • Moon, Byung-Seok;Lee, Tae-Sup;Lee, Myoung-Keun;Lee, Kyo-Chul;An, Gwang-Il;Chun, Kwon-Soo;Awh, Ok-Doo;Chi, Dae-Yoon;Choi, Chang-Woon;Lim, Sang-Moo;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.218-227
    • /
    • 2006
  • Purpose: The HSV1-tk reporter gene system is the most widely used system because of its advantage that direct monitoring is possible without the introduction of a separate reporter gene in case of HSV1-tk suicide gene therapy. In this study, we investigate the usefulness of the reporter probe (substrate), $9-(4-[^{18}F]Fluoro-3-hydroxymethylbutyl)$guanine ($[^{18}F]FHBG$) for non-invasive reporter gene imaging using PET in HSV1-tk expressing hepatoma model. Materials and Methods: Radiolabeled FHBG was prepared in 8 steps from a commercially available triester. The labeling reaction was carried out by NCA nucleophilic substitution with $K[^{18}F]/K2.2.2.$ in acetonitrile using N2-monomethoxytrityl-9-14-(tosyl)-3-monomethoxytritylmethylbutyl]guanine as a precursor, followed by deprotection with 1 N HCl. Preliminary biological properties of the probe were evaluated with MCA cells and MCA-tk cells transduced with HSV1-tk reporter gene. In vitro uptake and release-out studies of $[^{18}F]FHBG$ were performed, and was analyzed correlation between $[^{18}F]FHBG$ uptake ratio according to increasing numeric count of MCA-tk cells and degree of gene expression. MicroPET scan image was obtained with MCA and MCA-tk tumor bearing Balb/c-nude mouse model. Results: $[^{18}F]FHBG$ was purified by reverse phase semi-HPLC system and collected at around 16-18 min. Radiothemical yield was about 20-25%) (corrected for decay), radiochemical purity was >95% and specific activity was around >55.5 $GBq/{\mu}\;mol$. Specific accumulation of $[^{18}F]FHBG$ was observed in HSV1-tk gene transduced MCA-tk cells but not in MCA cells, and consecutive 1 hour release-out results showed more than 86% of uptaked $[^{18}F]FHBG$ was retained inside of cells. The uptake of $[^{18}F]FHBG$ was showed a highly significant linear correlation ($R^2=0.995$) with increasing percentage of MCA-tk numeric cell count. In microPET scan images, remarkable difference of accumulation was observed for the two type of tumors. Conclusion: $[^{18}F]FHBG$ appears to be a useful as non-invasive PET imaging substrate in HSV1-tk expressing hepatoma model.

Susceptibility Vessel Sign for the Detection of Hyperacute MCA Occlusion: Evaluation with Susceptibility-weighted MR Imaging

  • Lee, Sangmin;Cho, Soo Bueum;Choi, Dae Seob;Park, Sung Eun;Shin, Hwa Seon;Baek, Hye Jin;Choi, Ho Cheol;Kim, Ji-Eun;Choi, Hye Young;Park, Mi Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.105-113
    • /
    • 2016
  • Purpose: Susceptibility vessel sign (SVS) on gradient echo image, which is caused by MR signal loss due to arterial thrombosis, has been reported in acute middle cerebral artery (MCA) infarction. However, the reported sensitivity and diagnostic accuracy of SVS have been variable. Susceptibility-weighted imaging (SWI) is a newly developed MR sequence. Recent studies have found that SWI may be useful in the field of cerebrovascular diseases, especially for detecting the presence of prominent veins, microbleeds and the SVS. The purpose of this study was to evaluate the diagnostic values of SWI for the detection of hyperacute MCA occlusion. Materials and Methods: Sixty-nine patients (37 males, 32 females; 46-89 years old [mean, 69.1]) with acute stroke involving the MCA territory underwent MR imaging within 6 hours after the symptom onset. MR examination included T2, FLAIR (fluid-attenuated inversion recovery), DWI, SWI, PWI (perfusion-weighted imaging), contrast-enhanced MR angiography (MRA) and contrast-enhanced T1. Of these patients, 28 patients also underwent digital subtraction angiography (DSA) within 2 hours after MR examination. Presence or absence of SVS on SWI was assessed without knowledge of clinical, DSA and other MR imaging findings. Results: On MRA or DSA, 34 patients (49.3%) showed MCA occlusion. Of these patients, SVS was detected in 30 (88.2%) on SWI. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of SWI were 88.2%, 97.1%, 96.8%, 89.5% and 92.8%, respectively. Conclusion: SWI was sensitive, specific and accurate for the detection of hyperacute MCA occlusion.

Color Enhancement of Low Exposure Images using Histogram Specification and its Application to Color Shift Model-Based Refocusing

  • Lee, Eunsung;Kang, Wonseok;Kim, Sangjin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.1
    • /
    • pp.8-16
    • /
    • 2012
  • An image obtained from a low light environment results in a low-exposure problem caused by non-ideal camera settings, i.e. aperture size and shutter speed. Of particular note, the multiple color-filter aperture (MCA) system inherently suffers from low-exposure problems and performance degradation in its image classification and registration processes due to its finite size of the apertures. In this context, this paper presents a novel method for the color enhancement of low-exposure images and its application to color shift model-based MCA system for image refocusing. Although various histogram equalization (HE) approaches have been proposed, they tend to distort the color information of the processed image due to the range limits of the histogram. The proposed color enhancement algorithm enhances the global brightness by analyzing the basic cause of the low-exposure phenomenon, and then compensates for the contrast degradation artifacts by using an adaptive histogram specification. We also apply the proposed algorithm to the preprocessing step of the refocusing technique in the MCA system to enhance the color image. The experimental results confirm that the proposed method can enhance the contrast of any low-exposure color image acquired by a conventional camera, and is suitable for commercial low-cost, high-quality imaging devices, such as consumer-grade camcorders, real-time 3D reconstruction systems, digital, and computational cameras.

  • PDF

Experimental of Cerebral Vasospasm and Measure the Mean Blood Flow Velocity in the Middle Cerebral Artery

  • Park Byung-Rae
    • Biomedical Science Letters
    • /
    • v.11 no.4
    • /
    • pp.435-439
    • /
    • 2005
  • To determine the appropriate concentration of papaverine hydrochloride(PPV) for therapeutic intraarterial infusion against cerebral vasospasm and to measure the mean blood flow velocity of the middle cerebral artery in rabbits. Vasospasm was induced in the experimental groups (3 days after infusion; group 1, n=3, 7 days after infusion; group 2, n=3) and a control group (n=l) by placing a blood clot in the subarachnoid space around the top of the internal carotid siphon. PPV (5 mg/kg) was infused into the internal carotid artery. The vascular diameters of the internal carotid artery (ICA) and middle cerebral artery (MCA) were measured on angiograms before and after infusion. The mean blood flow velocity in the MCA was measured on transcranial doppler sonograms before and 24 hours after infusion. After fixation, the MCA was dissected out, stained, and examined microscopically. After PPV infusion in both groups, vascular dilatation of about $20\%$ was seen. The mean increase in blood flow velocity in the group $1(30\%)$ was smaller than in the group $2(70\%)$. The mean blood flow velocity in the MCA decreased by about $30\%$ in both groups, but increased again after 24 hours nearly to the level before PPV infusion. PPV infusion may be more effective in early stages of vasospasm when vascular walls have fewer histologic changes.

  • PDF

Channel-Adaptive Streaming Scheme to Guarantee Media Quality in Mobile WiMAX (모바일 와이맥스에서 채널 적응적인 미디어 품질 보장 기법)

  • Kim, Dong-Chil;Chung, Kwang-Sue
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.10
    • /
    • pp.990-994
    • /
    • 2010
  • Mobile WiMAX does not guarantee the media qualities because it does not consider the characteristics of video coding techniques. In this paper, PC-MCA(Priority-based Combining adaptive Modulation and Coding with ARQ), a priority based channel-adaptive streaming scheme, is proposed to guarantee media qualities. PC-MCA uses QoS scheduler by scheduling priority of the media and differentially controls modulation and coding schemes according to wireless channel condition and frame priorities. It also guarantees multimedia service quality through video decoding reliability.