• Title/Summary/Keyword: MBR sludge

Search Result 90, Processing Time 0.018 seconds

Case Study of Application of $SuperMAK^{R}$Submersed Hollow fiber Membrane) ($SuperMAK^{R}$(침지형분리막)을 적용한 오ㆍ폐수시설의 개 보수 사례)

  • 박헌휘;최영근;서창희;조재청;김수룡
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.123-123
    • /
    • 2004
  • 일반적인 활성슬러지 공정은 MLSS 1,500 - 3,000 mg/L 정도인데 MBR 공정은 보통 8,000 mg/L 이상의 농도로 운전할 수 있어, 높은 유기물 제거와 질산화 효율을 증가시킬 수 있다. 따라서 기존의 포기조 용량을 줄일 수 있으며 미생물의 자산화(Auto-Oxidation)가 증가하여 슬러지 발생량(Sludge Production)은 줄어들게 된다.(중략)

  • PDF

Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor (활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가)

  • Seo, Gyu-Tae;Lee, Teak-Soon;Park, Young-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.234-238
    • /
    • 2008
  • Coarse pore filter could be an alternative of membrane for solid-liquid separation in an activated sludge reactor because of inexpensive cost of the filter material and high flux at low filtration pressure. However such filter module has much less specific filtration area compared to the membrane. Therefore a certain effort is required to increase the specific filtration area in the module design of such coarse pore filter for solid-liquid separation in an activated sludge reactor. In this study, tubular type coarse pore filter was designed at various diameter and configuration. The filtration performance was investigated to separate solid in the activated sludge reactor for domestic wastewater treatment. Tubular type coarse pore filter module could be successfully applicable to solid separation in the activated sludge reactor. The design parameters were the tube diameter of 10mm and vertical installation. Smaller diameter of the tube caused faster increase of the filtration pressure because of the hydraulic head loss in the tube channel.

Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring (침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구)

  • Shin, Dong-Hwan;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.948-954
    • /
    • 2008
  • Membrane bioreactor(MBR) processes have been widely applied to wastewater treatment for last decades due to its excellent capability of solid-liquid separation. However, membrane fouling was considered as a limiting factor in wide application of the MBR process. Excess aeration into membrane surface is a common way to control membrane fouling in most MBR. However, the excessively supplied air is easily dissipated in the reactor, which results in consuming energy and thus, it should be modified for effective control of membrane fouling. In this study, cylindrical tube was introduced to MBR in order to use the supplied air effectively. Membrane fibers were immersed into the cylindrical tube. This makes the supplied air non-dissipated in the reactor so that membrane fouling could be controlled economically. Two different air supplying method was employed and compared each other; nozzle and porous diffuser which were located just beneath the membrane module. Transmembrane pressure(TMP) was monitored as a function of airflow rate, flux, and ratio of the tube area and cross-sectioned area of membrane fibers(A$_m$/A$_t$). Flow rate of air and liquid was regulated to obtain slug flow in the cylindrical tube. With the same flow of air supply, nozzle was more effective for controlling membrane fouling than porous diffuser. Accumulation of sludge was observed in the tube with the nozzle, if the air was not suppled sufficiently. Reduction of membrane fouling was dependent upon the ratio, A$_m$/A$_t$. For diffuser, membrane fouling was minimized when A$_m$/A$_t$ was 0.27, but 0.55 for nozzle.

Membrane Fouling Models for Activated Sludge Cakes (활성슬러지 케이크의 분리막 오염 모델)

  • Kim, Dae Chun;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.249-257
    • /
    • 2014
  • This experiment was carried out for a laboratory scale activated sludge bioreactor equipped with submerged flat sheet membrane using the synthetic wastewater. The membrane system for the activated sludge solution of MLSS 5,000 mg/L was operated with constant permeate flux by continuously permeating and periodically 10 minute-permeating/2 minute-resting modes, respectively. The transmembrane pressure was measured as the permeate flux increased from 10 to $25L/m^2{\cdot}hr$ under the constant air flowrate 0.25 L/min. Also, the complete blocking, standard blocking, intermediate blocking, incompressible cake and linear compressible cake fouling models were retrofitted for the experimental data in order to determine the state of the membrane fouling. Because the transmembrane pressure fluctuated as a pulse shape for every period of 10 minute-permeating/2-minute resting mode, the membrane fouling models were separately applied for the maximum and minimum connecting lines. The linear compressible cake fouling model for the activated sludge cakes was the best fitted with the experimental results from the above five models.

Behavior of Soluble Microbial Products by the Internal Recycle Rate in MBR Process (MBR공정에서 내부 반송비에 따른 생물대사성분의 거동)

  • Lee, Won-Bae;Cha, Gi-Cheol;Jeong, Tae-Young;Kim, Dong-Jin;Yoo, Ik-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.602-608
    • /
    • 2005
  • A laboratory-scale experiment was conducted to investigate control of soluble microbial products (SMP) by the internal recycle rate in the submerged membrane separation activated sludge process. The internal recycle rate of the reactor RUN 1 and RUN 2 were 100 % and 200 %, respectively. SMP concentration was rapidly accumulated in the reactor (RUN 1). The variation of accumulated SMP concentration was related to the denitrification rate at the beginning experiment however SMP concentration decreased without correlatively to the denitrification rate during long operation time. The microbial kinetic model was rapidly presented in the both microbial growth and extinction in the reactor (RUN 1). In the SMP kinetic model, Internal recycle rate is the lower, value of UAP and BAP which SMP matter were presented low. The study about development of kinetic model is relatively well adjusted to the experiment exception SMP. In the future, SMP formation equation must be thought that continually research is necessary.

WASTEWATER TREATMENT USING COMBINATION OF MBR EQUIPPED WITH NON-WOVEN FABRIC FILTER AND OYSTER-ZEOLITE COLUMN

  • Jung, Yoo-Jin;Koh, Hyun-Woong;Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.247-256
    • /
    • 2005
  • A combination of the submerged membrane activated-sludge bioreactor(SMABR) equipped with non-woven fabric filter and oyster-zeolite (OZ) packed-bed adsorption column was studied to evaluate the advanced tertiary treatment of nitrogen and phosphorous. The non-woven filter module was submerged in the MBR and aeration was operated intermittently for an optimal wastewater treatment performance. Artificial wastewater with $COD_{Cr}$ of 220 mg/L, total nitrogen (T-N) of 45 mg/L, and total phosphorous (T-P) of 6 mg/L was used in this study. MLSS was maintained about $4,000\;{\sim}\;5,000\;mg/L$ throughout the experiments. The experiments were performed for 100-day with periodic non-woven filter washing. The results showed that $COD_{Cr}$ could be effectively removed in SMABR alone with over 94% removal efficiency. However, T-N and T-P removal efficiency was slightly lower than expected with SMABR alone. The permeate from SMABR was then passed through the OZ column for tertiary nutrients removal. The final effluent analysis confirmed that nutrients could be additionally removed resulting in over 87% and 46% removal efficiencies for T-N and T-P, respectively. The results of this study suggest that the waste oyster-shell can be effectively reclaimed as an adsorbent in advanced tertiary wastewater treatment processes in combination with SMABR equipped with non-woven fabric filter.

Optimization of air scouring for an effective control of membrane fouling in submerged MBR (침지형 MBR 공정의 공기 세정 최적화를 통한 효율적 막 오염 제어)

  • Kim, Jun-Young;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.645-652
    • /
    • 2016
  • A membrane module including grid was designed and introduced to MBR (membrane bio-reactor) for the purpose of better control of membrane fouling. It could be anticipated that the grid enhances the shear force of fluid-air mixture into the membrane surface by even-distributing the fluid-air to the membrane module. As MLSS concentration, packing density which is expressed in the ratio of the housing and the cross-sectional area of membrane fibers ($A_m/A_t$) and air-flow rate were changed, membrane foulings were checked by monitoring fouling resistances. The total fouling resistance ($R_c+R_f$) without grid installation (i.e., control) was $2.13{\times}10^{12}m^{-1}$, whereas it was reduced to $1.69{\times}10^{12}m^{-1}$ after the grid was installed. Regardless of the grid installation, the $R_c+R_f$ increased as the packing density increased from 0.09 to 0.28, however, the increment of resistance for the grid installation was less than that of the control. Increase in the air flow rate did not always guarantee the reduction of fouling resistance, indicating that the higher air flow rate can partially de-flocculate the activated sludge flocs, which led to severer membrane fouling. Consequently, installation of grids inside the housing have brought a beneficial effect on membrane fouling and optimum air flow rate is important to keep the membrane lowering fouling.

Transmembrane Pressure of Backwashing, Filtration/Relaxation and the Sinusoidal Flux Continuous Operation Modes for Submerged Plate Membrane (역세척, 여과/이완 및 사인파형 연속투과 운전방식에 따른 침지형 평막의 막간차압)

  • Kim, Jae Hyo;Kim, Eun Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2019
  • In this study, permeation experiments were conducted using naturally circulating spherical beads, backwashable plate membrane and the air supplied from the bottom of the MBR. The activated sludge solution was maintained at 8,000 mg/L of MLSS and compared transmembrane pressure (TMP) with respect to FR (filtration and relaxation), FR/BW (filtration and relaxation/backwashing), SFCO (sinusoidal filtration continuous operation) and SFCO/BW (sinusoidal filtration continuous operation/backwashing). As the backwashing flux decreased from 47 to $14L/m^2{\cdot}hr$, the TMP increased generally, but the TMP of FR system increased significantly comparing with SFCO. In addition, the backwashing method reduced more TMP comparing to the cleaning method using spherical beads, and it was confirmed that the operation method using the spherical beads and the backwashing simultaneously is more effective than each method.

Effect of Suction Pressures with Respect to the Operational Modes Using the Quorum Quenching in the Membrane Bioreactor (생물막 반응기내 quorum quenching을 이용한 운전방식에 따른 흡입 압력의 영향)

  • Min Hyeong, Kim;Eeung Mo, Koo;Hyeok, Kim;Hyun-Suk, Oh;Kun Yong, Chung
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.465-474
    • /
    • 2022
  • The suction pressure was measured with respect to operational time by the backwashable flat sheet membrane module in membrane bioreactor (MBR). The membrane module having the nominal pore size of 0.2 ㎛ and the effective membrane area of 128cm2 was submerged in MLSS 8,000 mg/L active sludge aqueous solution. The suction pressure was observed with respect to permeation flux and the quorum quenching (QQ) treatment. The effects of FR and SFCO operation methods were compared and analyzed in the experimental groups: vacant bead (VB), BH4 and DKY-1 beads. The suction pressure reduction was the most effective for the permeation flux 40 L/m2 ⋅h with the injection of DKY-1 QQ beads. Also, the suction pressure reduction by the backwashing method was more than twice for using DKY-1 QQ beads.

Study on Sludge Reduction by Sludge Solubilization and Change of Operation Conditions of Sewage Treatment Process (하수슬러지 가용화와 하수처리 운전조건 개선을 통한 하수슬러지 발생저감 연구)

  • Choi, In-Su;Jung, Hoe-Suk;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1113-1122
    • /
    • 2009
  • In order to find the way to solve the problem of sewage sludge discharge into the ocean, the sludge solubilization by ultrasonic and the improvement methods of wastewater treatment process were studied. In the membrane bioreactor the sludge retention time was stepwise increased from 5.1 day to 442 days where the biomass average concentration has been increased from $c_B$=3.4 $gTSSL^{-1}$ to $c_B$=14.5 $gTSSL^{-1}$ respectively. At the same time, the biomass yield coefficients were reduced from 0.5-0.7 at SRT=5.1 day to 0.005-0.007 at SRT=442 days which means the reduction of sludge production. Oxygen mass transfer coefficients and ${\alpha}$-factor were investigated with changing stirrer speed to find the relation between the high biomass concentration and aeration efficiency in the propeller loop reactor. As a result of sludge solubilization, the solubilization of sludge by ultrasound was increased with increasing energy input and it led to improved anaerobic digestion rate with more biogas production than that of nonsolubilized sewage sludge.