• 제목/요약/키워드: M-health system

검색결과 1,231건 처리시간 0.029초

Structural health rating (SHR)-oriented 3D multi-scale finite element modeling and analysis of Stonecutters Bridge

  • Li, X.F.;Ni, Y.Q.;Wong, K.Y.;Chan, K.W.Y.
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.99-117
    • /
    • 2015
  • The Stonecutters Bridge (SCB) in Hong Kong is the third-longest cable-stayed bridge in the world with a main span stretching 1,018 m between two 298 m high single-leg tapering composite towers. A Wind and Structural Health Monitoring System (WASHMS) is being implemented on SCB by the Highways Department of The Hong Kong SAR Government, and the SCB-WASHMS is composed of more than 1,300 sensors in 15 types. In order to establish a linkage between structural health monitoring and maintenance management, a Structural Health Rating System (SHRS) with relevant rating tools and indices is devised. On the basis of a 3D space frame finite element model (FEM) of SCB and model updating, this paper presents the development of an SHR-oriented 3D multi-scale FEM for the purpose of load-resistance analysis and damage evaluation in structural element level, including modeling, refinement and validation of the multi-scale FEM. The refined 3D structural segments at deck and towers are established in critical segment positions corresponding to maximum cable forces. The components in the critical segment region are modeled as a full 3D FEM and fitted into the 3D space frame FEM. The boundary conditions between beam and shell elements are performed conforming to equivalent stiffness, effective mass and compatibility of deformation. The 3D multi-scale FEM is verified by the in-situ measured dynamic characteristics and static response. A good agreement between the FEM and measurement results indicates that the 3D multi-scale FEM is precise and efficient for WASHMS and SHRS of SCB. In addition, stress distribution and concentration of the critical segments in the 3D multi-scale FEM under temperature loads, static wind loads and equivalent seismic loads are investigated. Stress concentration elements under equivalent seismic loads exist in the anchor zone in steel/concrete beam and the anchor plate edge in steel anchor box of the towers.

수도권 지하철 전동차에서의 라돈 농도 분포 조사 (Indoor Radon Levels in the Subway Cabins of the Seoul Metropolitan Area)

  • 전재식;서종원;전명진;엄석원;채영주
    • 한국대기환경학회지
    • /
    • 제28권4호
    • /
    • pp.374-383
    • /
    • 2012
  • In this study, we have observed the airborne radon levels in the subway cabins before and after platform screen doors (PSD) installation. The measurements have been conducted at Seoul metropolitan subway lines in 2008, 2009 and 2010. The mean concentration of the radon inside subway cabins were increased by approximately 53% from $20.1Bq/m^3$ to $30.8Bq/m^3$ by installing PSD. After PSD installation, measured values for the different lines were rather different, and varied between 8.2 and $76.5Bq/m^3$. And mean radon concentrations were in the decreasing order for subway lines 5, 6, 7, 8, 3, 4, 2, 9 and 1. It was also found that the indoor radon concentrations in the subway cabins were highly dependent on the management approach of a ventilation system at the subway stations. By assuming an average of $720\;h\;year^{-1}$ and $2,880\;h\;year^{-1}$ spent in subway cabin, effective doses to passengers and employee were estimated. The expected annual effective dose, in case of an equilibrium factor of 0.4, were $0.07mSv\;y^{-1}$ and $0.26mSv\;y^{-1}$, respectively.

The effect of implant drilling speed on the composition of particle collected during site preparation

  • Jeong, Chang-Hee;Kim, Do-Young;Shin, Seung-Yun;Hong, Jong-Rak;Kye, Seung-Beom;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • 제39권sup2호
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose: This study was aimed to evaluate the effect of implant drilling speed on the composition of particle size of collected bone debris. Methods: $Br{\aa}nemark$ $System^{(R)}$ drills were used to collect bone debris from 10 drilling holes (1 unit) at 1,500 rpm (Group A) and 800 rpm (Group B) in bovine mandible. After separating particles by size into > 500 ${\mu}m$, between 250 ${\mu}m$ and 500 ${\mu}m$, and < 250 ${\mu}m$ fractions, particle wet volume, dry volume, and weight were measured and the proportion of 3 fractions of bone debris to total wet volume, dry volume and weight was calculated as wet volume % , dry volume % and weight %. Results: No significant differences were found between Group A and B in wet volume, dry volume, and weight. However, of >500 ${\mu}m$ fractions, Group B had significantly higher wet volume %(P = 0.0059) and dry volume %(P = 0.0272) than in Group A. Conclusions: The drilling speed influenced the composition of particle size in collected drilling bone debris. The drilling in 800 rpm produced the more percentage of large particles than in 1,500 rpm. However, the drilling speed didn't effect on total volume of and weight of bone debris.

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

Rocatec system이 Zir-ceram과 간접복합수지간의 전단결합강도에 미치는 영향 (Effect of Rocatec system on Shear Bond Strength between Zir-Ceram and Sinfony Indirect Composite Resin)

  • 김동일;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.23-29
    • /
    • 2008
  • The purpose of this study is to evaluate possibility of using indirect composite resin instead of porcelain through the measurement of shear bond strength between zirconia core and indirect composite resin under treatment of $Rocatec^{TM}$ system for improving the adhesion of indirect composite resin. 20 cylindrical zirconia core specimens were divided into 2 groups, according to zirconia surface treatment and attached materials: 1) treated with sandblast and attached with indirect composite resin, 2) treated with sandblast + $Rocatec^{TM}$ system and attached with indirect composite resin. The shear bond strength of each experimental group was measured by MTS and the changes of zirconia core surface according to surface treatments were obtained by SEM observation and measurements of surface roughness. The mean shear bond strength values are $0.55\;{\pm}\;0.11MPa$(Group SC) and $1.16\;{\pm}\;0.46MPa$(Group SRC). The mean Ra values for the surface treatments were follows: $0.39\;{\pm}\;0.13$($100{\beta}_{{\mu}m}$ sandblast) and $0.50\;{\pm}\;0.03$($100{\beta}_{{\mu}m}$ sandblast + $Rocatec^{TM}$ system). In the analysis of EDS, Si element was detected in the Group SC. The shear bond strength between zirconia core and indirect composite resin was improved significantly by using $Rocatec^{TM}$ system.

  • PDF

돈사 작업장 유형에 따른 입자상 오염물질의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Concentrations and Emissions of Particulate Contaminants by Types of Swine Houses in Korea)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권2호
    • /
    • pp.141-146
    • /
    • 2005
  • Objectives: Particulate contaminants, such as total and respirable dusts, can harm the health of farm workers via several routes. The principal aims of this field study were to determine the concentrations and emissions of particulate contaminants: total and respirable dusts, in the different types of swine houses used in Korea, and allow objective comparison between Korea and the other countries in terms of swine housing types. Methods: The swine houses investigated in this research were selected with respect to three criteria: the manure removal system, ventilation mode and growth stage of pigs. Measurements of total and respirable dust concentrations and emissions in the swine houses were carried out on 5 housing types at 15 different farm sites per housing type. The swine houses investigated were randomly selected from farms situated within the central districts in Korea: province of Kyung-gi, Chung-buk and Chung-nam. Results: The total and respirable dust concentrations in the swine houses averaged $1.88\;and\;0.64mg/m^3$, ranging from $0.53\;to\;4.37mg/m^3$ and from $0.18\;to\;1.68mg/m^3$, respectively. The highest concentrations of total and respirable dusts were found in the swine houses with deep-litter bed systems: $2.94mg/m^3\;and\;1.14 mg/m^3$, while the lowest concentrations were found in the naturally ventilated buildings with slats: $0.83mg/m^3\;and\;0.24mg/m^3$, respectively (p<0.05). All the swine houses investigated did not exceed the threshold limit values (TLVs) for total ($10mg/m^3$) and respirable ($2.5mg/m^3$) dusts. The mean emissions of total and respirable dusts, per pig (75 kg in terms of live weight) and area ($m^2$), from the swine houses were 97.33 and 9.55 mg/h/pig and $37.14\;and\;12.83mg/h/m^2$, respectively. The swine houses with deep-litter bed systems showed the highest emissions of total and respirable dusts (p<0.05). However, the emissions of total and respirable dusts from the other swine houses were not significantly different (p>0.05). Conclusion: The concentrations and emissions of total and respirable dusts were relatively higher in the swine houses managed with deep-litter bed systems and ventilated naturally of the different swine housing types tested. In further research, more farms than the number used in this research should be investigated, which will present objective and accurate data on the concentrations and emissions of total and respirable dusts in Korean swine houses. In addition, personal sampling should be performed to objectively assess the exposure level of farm workers to particulate contaminants.

Evaluation of the biocidal effects of activated carbon filter supporting silver

  • Moon, Kyong-Whan;Kim, Young-Whan;Choi, Dal-Woong
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.202-206
    • /
    • 2004
  • The objectives of this study are to investigate the relationship between the silver ion concentrations released from the point-of-use(POU) water purification devices installed silver impregnated activated carbon filters and the antibacterial activities against HPC bacteria. Total of 68 POU devices were tested. The concentrations of the eluted silver ion from the silver impregnated activated carbon filter showed the range from $4\;{\mu}g/L$ to $386\;{\mu}g/L$, and the HPC bacteria were found to diversely grow within the range 0-5,200 cfu/mL. The average silver concentrations released from UF units system and RO units system were $30\;{\mu}g/L$ and $73\;{\mu}g/L$, respectively. And the number of colonies were reduced significantly as the elution levels of silver exceeded $100\;{\mu}g/L$, however silver ions below the concentration of $100\;{\mu}g/L$ were not particularly effective for eradicating HPC bacteria from water.

  • PDF

Schedule communication routing approach to maximize energy efficiency in wireless body sensor networks

  • Kaebeh, Yaeghoobi S.B.;Soni, M.K.;Tyagi, S.S.
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.225-234
    • /
    • 2018
  • E-Health allows you to supersede the central patient wireless healthcare system. Wireless Body Sensor Network (WBSN) is the first phase of the e-Health system. In this paper, we aim to understand e-Health architecture and configuration, and attempt to minimize energy consumption and latency in transmission routing protocols during restrictive latency in data delivery of WBSN phase. The goal is to concentrate on polling protocol to improve and optimize the routing time interval and schedule communication to reduce energy utilization. In this research, two types of network models routing protocols are proposed - elemental and clustering. The elemental model improves efficiency by using a polling protocol, and the clustering model is the extension of the elemental model that Destruct Supervised Decision Tree (DSDT) algorithm has been proposed to solve the time interval conflict transmission. The simulation study verifies that the proposed models deliver better performance than the existing BSN protocol for WBSN.

Development and application of construction monitoring system for Shanghai Tower

  • Li, Han;Zhang, Qi-Lin;Yang, Bin;Lu, Jia;Hu, Jia
    • Smart Structures and Systems
    • /
    • 제15권4호
    • /
    • pp.1019-1039
    • /
    • 2015
  • Shanghai Tower is a composite structure building with a height of 632 m. In order to verify the structural properties and behaviors in construction and operation, a structural health monitoring project was conducted by Tongji University. The monitoring system includes sensor system, data acquisition system and a monitoring software system. Focusing on the health monitoring in construction, this paper introduced the monitoring parameters in construction, the data acquisition strategy and an integration structural health monitoring (SHM) software. The integration software - Structural Monitoring/ Analysis/ Evaluation System (SMAE) is designed based on integration and modular design idea, which includes on-line data acquisition, finite elements and dynamic property analysis functions. With the integration and modular design idea, this SHM system can realize the data exchange and results comparison from on-site monitoring and FEM effectively. The analysis of the monitoring data collected during the process of construction shows that the system works stably, realize data acquirement and analysis effectively, and also provides measured basis for understanding the structural state of the construction. Meanwhile, references are provided for the future automates construction monitoring and implementation of high-rise building structures.

이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계 (Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC)

  • 신영산;위재경;송인채
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.68-73
    • /
    • 2013
  • 본 논문에서는 수면 중에 사용자의 건강상태를 모니터링 하기 위한 U-health 시스템으로 맥박 수와 맥박 파형 검출 회로를 제안하였다. 제안된 검출 회로의 출력은 배터리의 교체 없이 장시간 사용하기 위하여 건강 상태에 따라 맥박 수 또는 맥박 파형이 선택된다. 이러한 동작을 위해 제안된 신호 검출 회로는 ADC 모드 또는 카운트 모드로 동작하는 이중 모드 ADC와 간단한 디지털 로직으로 구성된 판별기를 사용하였다. 우선 초기에는 카운트 모드로 동작하는 이중 모드 ADC를 통해 4초 동안의 맥박 수를 검출한다. 검출된 맥박수는 판별기에서 1분간 누적한 뒤 건강 상태를 판별한다. 건강 이상 등으로 맥박 수가 설정된 정상 범위를 벗어난 경우 이중 모드 ADC는 ADC 모드로 동작하며 맥박 파형을 1kHz의 샘플링 주파수로 10bit의 디지털 데이터로 변환한다. 데이터는 버퍼에 저장하였다가 620kbps의 속도로 RF Tx를 통해 단말기로 전송한다. 이때 RF Tx는 모드에 따라 1분 혹은 1ms 간격으로 동작한다. 제안된 신호 검출 회로는 $0.11{\mu}m$ 공정으로 설계하였으며 $460{\times}800{\mu}m^2$의 면적을 차지한다. 측정결과 제안된 검출 회로는 1V의 동작 전압에서 카운트 모드에서는 $161.8{\mu}W$, ADC 모드에서는 $507.3{\mu}W$의 전력을 소모한다.