• 제목/요약/키워드: M/W(Micro Wave)

검색결과 19건 처리시간 0.032초

High Power Continuous-Wave and Graphene Q-switched Operation of Er:YAG Ceramic Lasers at ~1.6 ㎛

  • Wang, Yong;Chen, Hao;Shen, Deyuan;Zhang, Jian;Tang, Dingyuan
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.5-9
    • /
    • 2013
  • We report on high-power continuous-wave operations of an Er:YAG ceramic laser in-band pumped by a cladding-pumped Er,Yb fiber laser at 1532 nm. With an output coupler of 10% transmission, the ceramic laser yielded 16.7 W of continuous-wave output at 1645 nm for 28.8 W of incident pump power, corresponding to a slope efficiency of 61.0% with respect to the incident pump power. The lasing wavelength switched to 1617 nm when output couplers of > 20% transmission were used. Up to 16.2 W of 1617 nm output was generated for 33.0 W of incident pump power, corresponding to a slope efficiency of 51.8%. Graphene Q-switched operation of Er:YAG cermic laser at 1645 nm was also demonstrated with stable pulses of 30-74 kHz repetition rates and 1.5-6.4 ${\mu}s$ pulse widths.

대열차 공간 화상설비의 무선설비 현황 및 전망 (Present Condition and View on the Wireless Communications of Geo-spatial Video System in Subway Trains)

  • 김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.366-370
    • /
    • 2007
  • This paper discusses a most suitable wireless communications system for subway trains on condition that a geo-spatial video system is implemented in subway trains. Geo-spatial video system for subway trains refers to the device that can transfers the images captured by cameras within a subway station building or in and around a subway track to on coming trains wirelessly, which allows the operator in operating room to monitor the state of a platform and a subway track, the flow of passengers, and the condition of passengers getting on and off. To minimize the problem, secure civil safety and prevent accidents and calamity from occurring, a geo-spatial video system for subway trains has been increasingly introduced. The wireless communications systems for GVS for subway trains involve HF(High Frequency), IR(Infra Red), M/W(Micro Wave), wireless LAN approaches. Each has its own strengths/weaknesses, and different vendors have different technology.

  • PDF

마이크로파 플라즈마 CVD법에 의한 섬유집합조직 다이아몬드막의 합성 (Synthesis of fiber-textured diamond films by MWPECVD)

  • 박재철;김병상
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.470-475
    • /
    • 1996
  • Fiber-textured diamond films have been deposited on scratched silicon(100) substrate by micro wave .plasma enhanced chemical vapor deposition at the condition of micro wave power : 950 W, pressure : 60 torr, H$_{2}$ gas flow rate : 50 sccm, CH$_{4}$ gas flow rate : 1.5 sccm, substrate temperature : about 900.deg. C and deposition time : 20 hours. The films were characterized by mean of scanning electron microscopy, Raman spectroscopy and X-ray analysis.

  • PDF

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

인쇄회로 기판에 내장된 마이크로 플럭스게이트 센서 (A MICRO FLUXGATE SENSOR IN PRINTED CIRCUIT BOARD (PCB))

  • 최원열;황준식;나경원;강명삼;최상언
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.151-155
    • /
    • 2002
  • This paper presents a micro fluxgate magnetic sensor in printed circuit board (PCB). The fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a micro patterned amorphous magnetic ribbon with extremely high DC permeability of ∼100,000 and the core has a rectangular-ring shape. The amorphous magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. Four outer layers as an excitation and pick-up coils have a planar solenoid structure. The chip size of the fabricated sensing element is 7.3${\times}$5.7m㎡. Excellent linear response over the range of -100${\mu}$T to +100${\mu}$T is obtained with 540V/T sensitivity at excitation square wave of 3V$\_$P-P/ and 360kHz. The very low power consumption of ∼8mW was measured. This magnetic sensing element which measures the lower fields than 50${\mu}$T, is very useful for various applications such as: portable navigation systems, military research, medical research, and space research.

  • PDF

2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발 (Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor)

  • 박해석;심동식;나경원;황준식;최상언
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

고출력 CW Nd:YAG 레이저를 이용한 인코넬 600의 용접 특성 (Welding Characteristics of Inconel 600 using a high power CW Nd:YAG Laser)

  • 유영태;신호준;임기건
    • 한국공작기계학회논문집
    • /
    • 제13권6호
    • /
    • pp.119-126
    • /
    • 2004
  • The welding characteristics of Inconel 600 Alloy using a continuous wave Nd:YAG laser are experimentally investigated. The major process parameters studied in the present laser welding experiment were the positions of focus, laser power and travel speed of laser bean We measured the fusion zone size and its shape using an optical microscope for the observation of cross-sectional area. We performed two tests regarding the tension and the micro hardness for welding quality estimation. Then we measured residual stress in welds by electronic speckle pattern interferometry(ESPI). In conclusion the optimum butt welding process parameters were 0.5mm focus position, 1.6kW laser power, 1m/min travel speed and 5.5$\ell$/min assist gas discharge.

PCB 기판에 내장된 마이크로 플럭스게이트 센서 (Embedded Micro Fluxgate Sensor in Printed Circuit Board (PCB))

  • 최원열;황준식;강명삼;최상언
    • 한국전기전자재료학회논문지
    • /
    • 제15권8호
    • /
    • pp.702-707
    • /
    • 2002
  • This paper presents a micro fluxgate sensor in printed circuit board (PCB). The fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a micro patterned amorphous magnetic ribbon and the core has a rectangular-ring shape. The amorphous magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. Four outer layers as an excitation and pick-up coils have a planar solenoid structure. The chip size of the fabricated sensing element is 7.3$\times$5.7$\textrm{mm}^2$. Excellent linear response over the range of -100$\mu$T to +100$\mu$T is obtained with 540V/T sensitivity at excitation square wave of 3 $V_{p-p}$ and 360kHz. The very low power consumption of ~8mW was measured. This magnetic sensing element, which measures the lower fields than 50$\mu$T, is very useful for various applications such as: portable navigation systems, military research, medical research, and space research.h.

전자파에 노출된 생체두부의 전기생리적 변화의 측정에 관한 연구 (Measurement of electro-physiological changes in the brain exposed to eletromagnetic wave radiation)

  • 이준하;신현진;이상학;유동수;이무영;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제5권2호
    • /
    • pp.35-43
    • /
    • 1994
  • 전자파가 일상생활에서 생체에 많은 영향을 미치는 것으로 알려져 있으나 실제로 그 영향을 정성, 정량적으로 규명하는 것은 용이하지 않다. 본 연구에서는 생체의 전기적 신호를 이용하여 2.45GHz의 전자파에 노출시킨 토끼의 두부에 대한 영향을 측정하는 방법을 검토하였다. 연구결과, 두부모델의 손상정도는 뇌전위의 연속적인 FFT 신호처리에서 뇌활성도 저하를 관찰할 수 있었으며, 특정 주파수와 강도(최소허용전력과 치사전력)에 대한 기준 설정에 필요한 요소를 제시할 수 있었다.

  • PDF

PCB 다층 적층기술을 이용한 마이크로 플럭스게이트 자기 센서 (Micro fluxgate magnetic sensor using multi layer PCB process)

  • 최원열;황준식;최상언
    • 센서학회지
    • /
    • 제12권2호
    • /
    • pp.72-78
    • /
    • 2003
  • 본 논문은 마이크로 플럭스게이트 자기 센서 (micro fluxgate magnetic sensor)의 여자코일 선폭에 따른 자계 검출 특성 변화에 관한 것이다. 센서 제작을 위해 PCB 다층 적층기술을 사용하였으며, 연자성 코어를 둘러싼 여자코일 선폭을 각각 $260\;{\mu}m$$520\;{\mu}m$로 센서를 구현하였다. 센서는 모두 5층의 기판을 적층 하였으며, 가운데 (3번째)기판을 자성체 코어로, 자성체 코어 외부 (2번째와 4번째)기판을 여자코일로, 최외부 (1번째와 5번째)기판을 검출코일로 제작하였다. 연자성 코어로는 약 100,000의 큰 DC 투자율 (permeability)을 갖는 코발트 (Co)가 주성분인 아몰퍼스 재료를 사용하였으며, 자속 누설을 최소화하기 위해 사각 링 형태를 유지하였다. 솔레노이드 형태의 여자코일과 검출코일은 구리 재질로 제작되었다. $260\;{\mu}m$ 여자코일 선폭을 갖는 자기센서는 여자조건이 360 kHz, $3\;V_{p_p}$의 정현파일 경우에 780 V/T로 매우 우수한 감도를 보이고 있으며, $-100\;{\mu}T\;{\sim}\;+100\;{\mu}T$ 영역에서 매우 우수한 선형특성을 보이고 있다. 자기 센서의 크기는 $7.3\;{\times}\;5.7\;mm^2$이며, 소비전력은 약 8 mW이다. 이런 초소형 자기센서는 휴대용 네비게이션 시스템, telematics, VR 게임기 등 다양한 응용분야에 적용할 수 있다.