• Title/Summary/Keyword: M/N-Detector

Search Result 169, Processing Time 0.03 seconds

Association of the Risk of Leukemia and Non-Hodgkin's Lymphoma (NHL) with Environmental Agents (모 지역의 소아 백혈병 및 악성림프종 발병 사례와 환경적 요인의 연관성 조사)

  • Park, Dong-Uk;Choi, Sangjun;Youn, Kanwoo;Kim, So-Yeon;Kim, Hee-Yun;Park, Yun-Kyung;Kim, Won;Iim, Sanghyuk;Park, Jihoon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.203-212
    • /
    • 2019
  • Objective: A total of five students at same middle school were reported to be diagnosed with pediatric leukemia (n=2), non-Hodgkin's lymphoma (NHL, n=1) and aplastic anemia (n=2) between 2016 and 2017. The aims of this study are to assess exposure to environmental hazardous agents known to be associated with the risk of leukemia and to examine whether the environment of school is associated with the risk leukemia. Method: A total of 11 environmental agents causing childhood leukemia were monitored using international certified method in schools where patients had ever attended. Radon & Thoron detector was used to monitor real-time airborne radon and thoron level ($Bq/m^3$). Clinician interviewed two among nine patients who agreed to participate in this study in order to examine the association of demographic and genetic factors by individually. Leukemia, NHL, and aplastic anemia were grouped into lymphohematopoietic disorder (LHP). Results: Except for airborne radon level, no environmental agents in school and household where patients may be exposed were found to higher than recommended airborne level. Clinical investigation found no individual factors that may be associated with the risk of LHP. Higher airborne radon level than Korea EPA's airborne radon criteria ($148Bq/m^3$) was monitored at most of several after-class room of one elementary school, where two leukemia patients graduated. Significant radon level was not monitored at class-room. Significant exposure to radon of patients was not estimated based on time-activity pattern. Conclusions: Our results have concluded that there have been no environmental factors in school and household environment that may be associated the risk of LHP.

Biological Monitoring of Paint Handling Workers exposed to PAHs using Urinary 1-Hydroxypyrene (다핵방향족탄화수소류에 노출된 페인트 취급 근로자에서 요 중 1- Hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong-Seong;Kim, Eun-A;Lee, Yong-Hag;Moon, Deog-Hwan;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

Determination of Ethambutol n Human Plasma by a Validated HPLC Method and Its Application to Single-dose Pharmacokinetics (인체혈장 중 에탐부톨의 HPLC 분석법의 검증 및 단일용량 투여에 의한 약물동태 연구)

  • Gwak, Hey-Sun;Park, Kyung-Ho;Choi, Jun-Shik;Song, Gin-A;Sung, Min-Kyung;Jang, Jung-Ok;Lee, Hwa-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.2
    • /
    • pp.123-127
    • /
    • 2005
  • An HPLC method was employed for the determination of ethambutol in human plasma. After addition of internal standard (IS, octylamine, $2\;{\mu}g/mL$) and alkalinization of the plasma with 5 M sodium hydroxide, the drug and IS were extracted into the mixture of chloroform and diethyl ether (40:60, v/v). Following a 15-min vortex-mixing and a 10min centrifugation, the organic phase was spiked with $100{\mu}L$ of phenylethylisocyanate $(2000{\mu}g/mL)$ for chemical derivatization, mixed for 5 min and evaporated to dryness under a stream of nitrogen. The residue was reconstituted with $100{\mu}L$ of mobile phase and $20{\mu}L$ was injected into C18 column with a mobile phase consisting of methanol:water (70:30, v/v). The samples were detected utilizing an ultraviolet detector at 200 nm. The method was specific and validated with a limit of $0.15\;{\mu}g/mL$. Intra- and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification. The applicability of this method was demonstrated by analysis of human plasma after oral administration of a single 1200-mg dose to 20 healthy subjects. From the plasma ethambutol concentration vs. time curves, the mean AUC was $9.61{\pm}1.64\;{\mu}g{\cdot}hr/mL$ and Cmax of $2.68\;{\mu}g/mL$ reached 2.73 hr after administration. The mean biological half-life of ethambutol was $3.46{\pm}1.21$ hr. Based on the results, this simple and validated assay could readily be used in any pharmacokinetic studies using humans.

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.

Traveling-wave Ti:LiNbO3 optical modulator capable of complete switching (완전 스위칭이 가능한 Ti:LiNbO3 진행파 광변조기)

  • 곽재곤;김경암;김영문;정은주;피중호;박권동;김창민
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.545-554
    • /
    • 2003
  • Design of the optical modulator composed of a three-waveguide coupler and CPW traveling-wave electrodes was carried out. Switching phenomena of three-waveguide couplers were analyzed by using the coupled mode theory, and the coupling-lengths of the devices were calculated by means of the FDM. CPW traveling-wave electrodes were analysed by the CMM and SOR simulation technique in order to find the conditions of phase-velocity and impedance matching. Traveling-wave modulators were fabricated on z-cut LiNbO$_3$ substrate. Ti was in-diffused in LiNbO$_3$ to make waveguides and Au electrodes were built on the waveguides by the electrolyte technique. The fabricated modulator chip was end-polished, pig-tailed and packaged in a brass mount with K-connector. The insertion loss and the switching voltage of the optical modulator were about 4㏈ and 19V, respectively. Network analyzer was used to obtain the S parameter and the corresponding RF response. From the measurement, parameters of the traveling-wave electrodes were extracted to be Z$_{c}$= 45 Ω, N$_{eff}$=2.20, and $\alpha$$_{0}$=0.055/cm√GHZ. The measured optical response R($\omega$) was compared with the theoretically estimated one, showing both responses agree well. The measurement results revealed that 3㏈ bandwidth turned out to be about 13 GHz.

The Study on Characteristic Composition of As in a-Se with X-ray Detection Sensor using $CaWO_4/a-Se$ (다층구조($CaWO_4/a-Se$) 기반의 X선 검출센서에서 a-Se에 첨가된 As의 특성비 연구)

  • Choe, Jang-Yong;Lee, Dong-Gil;Sin, Jeong-Uk;Kim, Jae-Hyeong;Nam, Sang-Hee;Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.432-435
    • /
    • 2002
  • The ultimate study of this research is to improve the properties of digital X-ray receptor based on amorphous selenium. There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. But each two systems have strength and weakness. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. ln this study, we investigated the electrical characteristic of multi-layer$(CaWO_4+a-Se)$ as a photoconductor according to the changing iodine composition ratio. The iodine composition ratio of a-Se compound is classified into 5 different kinds which have 30ppm, 100ppm, 300ppm, 500ppm, 700ppm and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 700ppm iodine showed good characteristic of $2.53nA/cm^2$ dark current and $479nC/cm^2{\cdot}mR$ net charge at $3V/{\mu}m$.

  • PDF

Oxalate Chelating Activity of Egg White Proteins and Their Hydrolysates

  • Holipitiyage Shyami Rashmiki, Holipitiya;Palihawadanege Iresha Lakmini, Fernando;Ethige Chathura Nishshanka, Rathnapala;Alakolange Gedara Achala Wimukthika, Alakolanga;Edirisinghe Dewage Nalaka Sandun, Abeyrathne;Ki-Chang, Nam
    • Korean Journal of Poultry Science
    • /
    • v.49 no.4
    • /
    • pp.221-228
    • /
    • 2022
  • Major egg white proteins and their hydrolysates serve as functional food ingredients that have certain metal-chelating properties. Employing egg white proteins and their hydrolysates to scavenge dietary oxalates is anticipated to have beneficial effect in the prevention of kidney stones. The objective of this study was to determine the biogenic oxalate-chelating activity of ovalbumin, ovomucin, and ovotransferrin and their hydrolysates. To prepare oxalate extracts, 30 mL of 0.25 N HCl was added to separately to 0.5 g of dried spinach and starfruit powders followed by boiling for 15 min, and after cooling, the addition of a further 20 mL of 0.25 N HCl. Having prepared these extracts, ovalbumin, ovomucin, and ovotransferrin and their hydrolysates were separately mixed with oxalate extracts and incubated at 3℃ for 24 h. Following centrifugation, supernatants were analyzed by HPLC using a reverse-phase C18 column coupled with a diode array detector. We found that all assessed proteins and their hydrolysates showed biogenic oxalate-chelating activity against the oxalates of spinach. In contrast, however, only ovalbumin, ovalbumin-hydrolysate, and ovomucin showed chelating activity (57.10%±8.84%, 85.44%±5.30%, 73.20%±4.13%, respectively) against the oxalates of starfruit (P<0.05). Overall, hydrolyzed ovalbumin was identified as the most effective chelator of the oxalates both spinach and starfruit. In this study, we thus established that the assessed egg white proteins and their hydrolysates have oxalate-chelating activity in vitro, thereby indicating that these compounds have potential utility as nutraceuticals for the chelation of dietary oxalate. However, further research will be necessary to verify their oxalate-chelating activities against different fruits and vegetables and under specific in vivo conditions and against purified oxalate.

Levels of sulfonamides for animals in food (식품 중 설폰아마이드계 동물용의약품의 잔류실태)

  • Jeong, Jiyoon;Hong, Mooki;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.84-90
    • /
    • 2007
  • To determine levels of 11 sulfonamides for animals in food, simultaneously, a selective method of high performance liquid chromatography with UV detector has been applied. The targets were sulfachlorpyridazine (SCP), sulfadiazine (SDZ), sulfadimethoxine (SDM), sulfisoxazole (SSX), sulfamerazine (SMZ), sulfamethazine (SMT), sulfamethoxazole (SMX), sulfamethoxypyridazine (SMP), sulfamonomethoxine (SMM), sulfaquinoxaline (SQX) and sulfathiazole (STZ). Food samples were beef, pork, chicken, milk and whole egg that were collected at the main 6 cities in Korea as Seoul, Busan, Daejon, Incheon, Mokpo and Gangneung. After homogenizing food samples with sodium phosphate solution and acetonitrile, it was extracted with n-hexane. The mobile phase gradient was a mixture of 5 mM potassium phosphate (pH 3.25) and methanol with a gradient ratio from 100:0 to 30:70. The UV wavelength was 270 nm. The overall recoveries were ranged from 75% to 95% and the limit of detection was minimum 0.004 mg/kg for SMT, and 0.007 mg/kg for STZ at signal/noise > 3, respectively. As results, sulfonamide drugs were not detected in most of the selected food samples, however, sulfamonomethoxine was detected in meat. The determined level of sulfamonomethoxine were 0.03 and 0.06 mg/kg for beef that were below the MRLs.