• Title/Summary/Keyword: M&M

Search Result 159,593, Processing Time 0.169 seconds

Characteristics of Mass Transport Depending on the Feature of Tidal Creek at Han River Estuary, Gyeong-gi Bay, South Korea (경기만 염하수로에서의 비정규 격자 수치모델링을 통한 조간대 조수로의 고려에 따른 Mass Transport 특성)

  • Kim, Minha;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.41-51
    • /
    • 2013
  • The tidal creek dependent mass transport characteristic in Gyeong-Gi Bay (west coast of Korea) was studied using field measured data and numerical model. Gyeong-Gi Bay consists of 3 main tidal channels and contains a well-developed vast tidal flat. This region is famous for its large tidal difference and strong current. We aim to study the effect of tidal creek in the tidal flat on the mass exchange between the estuary and the ocean. For numerical application, the application of unstructured grid feature is essential, since the tidal creek has complicated shape and form. For this purpose, the FVCOM is applied to the study area and simulation is performed for 2 different cases. In case A, geographic characteristics of the tidal creek is ignored in the numerical grid and in case B, the tidal creek are constructed using unstructured grid. And these 2 cases are compared with the field measured cross-channel mass transport data. The cross-channel mass transport at the Yeomha waterway mouth and Incheon harbor was measured in June, 9~10 (Spring tide) and 17~18 (Neap tide), 2009. CTD casting and ADCP cross-channel transect was conducted 13 times in one tidal cycle. The observation data analysis results showed that mass transport has characteristic of the ebb dominance Line 1 (Yeomha waterway mouth), on the other hand, a flood dominant characteristic is shown in Line 2 (Incheon harbor front). By comparing the numerical model (case A & B) with observation data, we found that the case B results show much better agreement with measurement data than case A. It is showed that the geographic feature of tidal creek should be considered in grid design of numerical model in order to understand the mass transport characteristics over large tidal flat area.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

Recommended Methods for Surface Counting to Determine Sites of Red Cell Destruction - A Report by the Panel on Diagnostic Applications of Radioisotopes in Haematology of the International Committee for Standardization in Hematology

  • The Korea Society of Nuclear Medicine The Korea Society of Nuclear Medicine
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.57-62
    • /
    • 1974
  • 이 논문(論文)은 1973년(年) ICSH주최로 열린 panel에서 적혈구파괴(赤血球破壞) 장소(場所)를 결정(決定)하기 위한 생체(生體) 체표계측법(醫表計測法)의 표준화(標準化)에 관(關)한 토론(討論) 결과(結果)를 초록(抄錄)한 것이다. 체표계측(體表計測)은 체외(體外)에서 계측기(計測器)를 이용(利用)하여 각(各) 장기(臟器)에서의 방사표지물질(放射標識物質)의 분포(分布) 및 시간경과(時間經過)에 따른 변화(變化)를 측정(測定)하는 것으로서 $^{51}Cr$를 사용(使用)하여 적혈구수명(赤血球壽命)을 측정(測定)할 때 간(肝), 비(脾), 심장(心臟)의 방사능(放射能)을 계측(計測)한다. 이 방법(方法)은 각(各) 장기(臟器)에서의 적혈구파괴(赤血球破壞)의 정도(程度)를 예측할 수 있다. 특(特)히 용혈성(溶血性) 빈혈환자(貧血患者)에서 비장적출(脾臟摘出) 여부를 결정(決定)하는데 도움이 된다. 이 panel에서는 주(主)로 오차(誤差)의 원인(原因)이 되는 여러가지 요인(要因)에 대(對)하여 토론(討論)하였으며 일반적으로 다음과 같은 것에 의견(意見)의 일치(一致)를 보았다. 즉(卽) 비장(脾臟)의 위치(位置)는 $^{99m}Tc$로 비주사(脾走査)를 실시하여 결정(決定)하는것이 좋고, $^{51}Cr$은 체중(體重) 1kg당 $1.5{\mu}Ci$를 사용하여, 계측기(計測器)는 NaI crystal(직경이 5cm이상, 두께가 3.75cm이상)의 scintillation doctor를 사용하고, 계측(計測)은 $^{51}Cr$로 표지(標識)된 적혈구(赤血球) 주입후(注入後) 15분(分) 이후(以後)에 하고 다음날 계측(計測)한 후(後) 2주(週) 동안에 적어도 6번 계측(計測)한다. Data 처리는 excess count법(法)과 비(脾)와 간(肝)의 비(比)로서하는 것이 좋다.定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法),

  • PDF

Usefulness of Three-phasic Bone Scan in Young Male Patients Suspected of Post-traumatic Reflex Sympathetic Dystrophy Syndrome (외상후 교감신경 이영양증이 의심되는 젊은 남자 환자들에서 삼상 골스캔의 유용성)

  • Lee, Won-Woo;Kim, Tae-Uk;Kim, Tae-Hoon;Jung, Cheoul-Yun;Moon, Jin-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: In young male patients who suffered several kinds of trauma with subsequent suspicious reflex sympathetic dystrophy syndrome, we performed three-phasic bone scan in order to investigate its usefulness. Materials and Methods: Patients with narrow range of age (21-25. mean $22.8{\pm}1.3$, all male) were included with suspicious reflex sympathetic dystrophy syndrome of 12 feet and 5 hands. Only one was bilateral feet case and 16 were ipsilateral (Rt:13, Lt:3). The etiologic traumas were 4 fractures, 4 sprains, 3 blunt trauma, 2 cellulitis, 1 tendon tear, 1 crush injury, 1 overexercise, and 1 unknown. Radiologically 3 showed osteoporotic changes. Three-phasic bone scans were performed $21.2{\pm}7.3wks$ after trauma. Results: According to symptom complex, confirmatory reflex sympathetic dystrophy syndrome 4 cases and suspicious 13 were analyzed. All confirmatory cases (100%) showed increased uptake at delay phase with periarticular accentuation. Of confirmatory 4 cases, 2 showed increased uptake in all three phases (perfusion: P, blood pool: B, and delay: D), and other 2 revealed decreased P but, both increased B and D. Of suspicious 13 cases, 9(69.2%) had increased D (4 periarticular and 5 focal), 2 decreased D, and 2 symmetric D. In 12 foot cases, so-called weight hearing patterns - increased contralateral sole at P and B - were revealed in 7(58.3%). Conclusion: Diffuse periarticular increased uptake at delay phase of three-phasic bone scan was a compatible finding to reflex sympathetic dystrophy syndrome in young male patients whose symptom complex strongly designated post traumatic reflex sympathetic dystrophy syndrome.

  • PDF

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Correlation between Semiquantitative Myocardial Perfusion Score and Absolute Myocardial Blood Flow in $^{13}N-Ammonia$ PET ($^{13}N$-암모니아 PET에서 반정량적 심근관류 점수와 절대적 심근혈류량의 상관관계)

  • Lee, Byeong-Il;Kim, Kye-Hun;Kim, Jung-Young;Kim, Su-Jin;Lee, Jae-Sung;Min, Jung-Joon;Song, Ho-Chun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • Purpose: $^{13}N$-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Methods: Twelve patients (11 males, 1 female, $57.9{\pm}8.6$ years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: $5\;sec\;{\times}\;12,\;10\;sec\;{\times}\;6,\;20\;sec\;{\times}\;3,\;and\;30\;sec\;{\times}\;6$) were initiated simultaneously with bolus injection of 11 MBq/kg $^{13}N-ammonia$ to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. Results: There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Conclusions: Corrected and translated MPS as its characteristics using $^{13}N$-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study.

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.