• Title/Summary/Keyword: Lying posture

Search Result 45, Processing Time 0.031 seconds

Evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds, and illuminance

  • Kim, Yong Ju;Song, Min Ho;Lee, Sang In;Lee, Ji Hwan;Oh, Han Jin;An, Jae Woo;Chang, Se Yeon;Go, Young Bin;Park, Beom Jun;Jo, Min Seok;Lee, Chang Gyu;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • v.63 no.4
    • /
    • pp.790-798
    • /
    • 2021
  • The objective of this study was evaluation of pig behavior changes related to temperature, relative humidity, volatile organic compounds (VOCs), and illuminance. A total of 24 growing pigs ([Yorkshire × Landrace] × Duroc) were used in the experiment. A sensor was installed at a height of 0.5 m in the center of the pig house. In experiment 1, temperature was changed every four days to 18℃ (T1), 22℃ (T2), 26℃ (T3), and then 30℃ (T4). In experiment 2, relative humidity was adjusted to 45% (low humidity [LH]), 60% (middle humidity [MH]), and then 75% (high humidity [HH]) for four days. In experiment 3, after cleaning the pig house just before experiment, only minimal ventilation was provided. VOCs and pig behaviors were observed for 7 days without cleaning the pig house. In experiment 4, three light bulbs of 40 W (470 lumens / 45 lx; low illuminance [LI]), 75 W (1,055 lumens / 103 lx; middle illuminance [MI]), and 100 W (1,521 lumens / 146 lx; high illuminance [HI]) were used for four days each. Pig behavior analysis was performed for following criteria : Feed intake, Standing, Lying, Sitting, Drink water, Rooting, Posture transition (lying-standing), Posture transition (standing-lying), Wallowing, and Biting. In experiment 1, feed intake time was lower (p < 0.05) for the T3 than other treatment groups. Standing time was highest (p < 0.05) for the T1 and lowest (p < 0.05) for the T3. Lying time was shorter (p < 0.05) in T1 and T2 compared to T3 and T4. Drinking frequency was higher (p < 0.05) for the T4 than other treatment groups. In experiment 2, the frequency of rooting and wallowing increased (p < 0.05) with increasing humidity. LH showed the lowest (p < 0.05) rooting frequency and HH showed the highest (p < 0.05) rooting frequency. In experiment 3, VOCs concentration did not (p > 0.05) change pig behavior. In experiment 4, lying time was the longest (p < 0.05) at LI and shortest (p < 0.05) at HI. Therefore, pig behavior is heavily influenced by the environment, especially temperature and humidity. However, correlation between pig behavior to VOCs and illuminance seems to be needed more research.

The Effect of Abdominal Drawing-in Maneuver with Pressure Biofeedback Unit in Various Postures on Abdominal Muscle Contraction

  • Lee, Seunghoon;Lee, Sangyeol
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.136-144
    • /
    • 2022
  • Objective: This study was to identify the effect of pressure biofeedback applied in various postures that allow the application of abdominal drawing-in. Design: A cross sectional study. Methods: The study intended to compare changes in the thickness of abdominal muscles between different postures when abdominal drawing-in was performed using a pressure biofeedback unit in five postures and to compare differences in terms of measures such as the transverse abdominis's preferential activation ratio(PAR). Data measured from 30 healthy individuals were used for data analysis. A paired t-test and repeated measures analysis of variance was performed to compare the thickness of each abdominal muscle. Results: The transverse abdominis's and internal oblique's thickness showed statistically significant differences in all postures when abdominal drawing-in (p<0.05). In the comparison between the postures, statistically significant differences were observed between the positions of hook-lying and wall support standing and between supine and wall support standing and between hook-lying and sitting (p<0.05). In terms of the transverse abdominis's PAR in each posture, statistically significant differences were observed between hook-lying and quadruped, hook-lying and sitting, hook-lying and wall support standing, quadruped and supine, sitting and supine, as well as wall support standing and supine (p<0.05). Conclusions: When abdominal drawing-in using pressure biofeedback unit is performed for stabilization exercises, selecting and applying specific postures according to targeted muscles and the subject's functional ability will help provide a more efficient and accurate intervention.

Measurement Method of Posture and Movement for the Aged Person using an Accelerometer

  • Sugimoto, Takao;Mori, Kentarou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.87-91
    • /
    • 2004
  • High aged society is rapidly progressing in Japan. The rate of aged person more than 65 years old in the population are estimated 25 % in 2017 and rate of younger population will be decreased at same time. As a result, it is estimated that the human resources that is looking after or supporting for the aged person will be drained in Japan. In the other hand, the society has to provide high quality of life in order to be improved living environment for aged person. To decrease the share of nursing and caring for the aged person, it is required that new supporting systems for aged person have to build up as soon as possible. But it is required that various kind of measurement for posture and movement in activities with a simple and single detector for the aged person. The measurement instrument has to be lightweight and simple structure. The results give us a simple measurement method are classified that the posture of sitting down, lying down in stationary statuses and walking, running and going to up and down on the stairs in moving statuses. The detected data will plane to transmit to wireless mobile system to the host computer.

  • PDF

A Study on Estimation of Lying Posture at Multiple Angles Using Single Frequency Modulated Continuous Wave (FMCW) Radar-Based CNNs (FMCW 레이더 및 CNN을 이용한 다양한 각도로 누운 자세 추정 연구)

  • Jang, Kyongseok;Zhou, Junhao;Kim, Youngok
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.349-350
    • /
    • 2023
  • 본 논문에서는 FMCW(Frequency Modulated Continuous Wave) 레이더를 사용하여 재난 상황에서 누워 있는 사람의 다양한 각도의 자세를 통해 사람의 상태를 파악하거나 위치를 추정하고자하였다. 사람의 세 가지 누운 자세 데이터를 전처리하고 이미지로 변환한 데이터를 CNN(Convolutional Neural Network) 1D 모델로 학습시켜 누운 자세를 다양한 각도에서 구별할 수 있는지 분석하여 확인하고자하였으며, 분석 결과 CNN 1D 모델은 99.27%의 정확도를 보였다.

  • PDF

Clinical Characteristics of Peroneal Nerve Palsy by Posture

  • Yu, Jeong Keun;Yang, Jin Seo;Kang, Suk-Hyung;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.5
    • /
    • pp.269-273
    • /
    • 2013
  • Objective : Posture induced common peroneal nerve (CPN) palsy is usually produced during the prolonged squatting or habitual leg crossing while seated, especially in Asian culture and is manifested by the onset of foot drop. Because of its similarity to discogenic foot drop, patients may be diagnosed with a lumbar disc disorder, and in some patients, surgeons may perform unnecessary examinations and even spine surgery. The purpose of our study is to establish the clinical characteristics and diagnostic assessment of posture induced CPN palsy. Methods : From June 2008 to June 2012, a retrospective study was performed on 26 patients diagnosed with peroneal nerve palsy in neurophysiologic study among patients experiencing foot drop after maintaining a certain posture for a long time. Results : The inducing postures were squatting (14 patients), sitting cross-legged (6 patients), lying down (4 patients), walking and driving. The mean prolonged neural injury time was 124.2 minutes. The most common clinical presentation was foot drop and the most affected sensory area was dorsum of the foot with tingling sensation (14 patients), numbness (8 patients), and burning sensation (4 patients). The clinical improvement began after a mean 6 weeks, which is not related to neural injury times. Electrophysiology evaluation was performed after 2 weeks later and showed delayed CPN nerve conduction study (NCS) in 24 patients and deep peroneal nerve in 2 patients. Conclusion : We suggest that an awareness of these clinical characteristics and diagnostic assessment methods may help clinicians make a diagnosis of posture induced CPN palsy and preclude unnecessary studies or inappropriate treatment in foot drop patients.

An Untrained Person's Posture Estimation Scheme by Exploiting a Single 24GHz FMCW Radar and 2D CNN (단일 24GHz FMCW 레이더 및 2D CNN을 이용하여 학습되지 않은 요구조자의 자세 추정 기법)

  • Kyongseok Jang;Junhao Zhou;Chao Sun;Youngok Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.897-907
    • /
    • 2023
  • Purpose: In this study, We aim to estimate a untrained person's three postures using a 2D CNN model which is trained with minimal FFT data collected by a 24GHz FMCW radar. Method: In an indoor space, we collected FFT data for three distinct postures (standing, sitting, and lying) from three different individuals. To apply this data to a 2D CNN model, we first converted the collected data into 2D images. These images were then trained using the 2D CNN model to recognize the distinct features of each posture. Following the training, we evaluated the model's accuracy in differentiating the posture features across various individuals. Result: According to the experimental results, the average accuracy of the proposed scheme for the three postures was shown to be a 89.99% and it outperforms the conventional 1D CNN and the SVM schemes. Conclusion: In this study, we aim to estimate any person's three postures using a 2D CNN model and a 24GHz FMCW radar for disastrous situations in indoor. it is shown that the different posture of any persons can be accurately estimated even though his or her data is not used for training the AI model.

A computer vision-based approach for behavior recognition of gestating sows fed different fiber levels during high ambient temperature

  • Kasani, Payam Hosseinzadeh;Oh, Seung Min;Choi, Yo Han;Ha, Sang Hun;Jun, Hyungmin;Park, Kyu hyun;Ko, Han Seo;Kim, Jo Eun;Choi, Jung Woo;Cho, Eun Seok;Kim, Jin Soo
    • Journal of Animal Science and Technology
    • /
    • v.63 no.2
    • /
    • pp.367-379
    • /
    • 2021
  • The objectives of this study were to evaluate convolutional neural network models and computer vision techniques for the classification of swine posture with high accuracy and to use the derived result in the investigation of the effect of dietary fiber level on the behavioral characteristics of the pregnant sow under low and high ambient temperatures during the last stage of gestation. A total of 27 crossbred sows (Yorkshire × Landrace; average body weight, 192.2 ± 4.8 kg) were assigned to three treatments in a randomized complete block design during the last stage of gestation (days 90 to 114). The sows in group 1 were fed a 3% fiber diet under neutral ambient temperature; the sows in group 2 were fed a diet with 3% fiber under high ambient temperature (HT); the sows in group 3 were fed a 6% fiber diet under HT. Eight popular deep learning-based feature extraction frameworks (DenseNet121, DenseNet201, InceptionResNetV2, InceptionV3, MobileNet, VGG16, VGG19, and Xception) used for automatic swine posture classification were selected and compared using the swine posture image dataset that was constructed under real swine farm conditions. The neural network models showed excellent performance on previously unseen data (ability to generalize). The DenseNet121 feature extractor achieved the best performance with 99.83% accuracy, and both DenseNet201 and MobileNet showed an accuracy of 99.77% for the classification of the image dataset. The behavior of sows classified by the DenseNet121 feature extractor showed that the HT in our study reduced (p < 0.05) the standing behavior of sows and also has a tendency to increase (p = 0.082) lying behavior. High dietary fiber treatment tended to increase (p = 0.064) lying and decrease (p < 0.05) the standing behavior of sows, but there was no change in sitting under HT conditions.

A Newly Designed Cervical Pillow Department of Rehabilitation Medicine (새로 디자인된 경부베개)

  • He, Jin-Gang
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.2
    • /
    • pp.1063-1073
    • /
    • 1999
  • Objective: Poor head and neck support during sleep can exacerbate the neck pain. Based on the ideal sleep posture and pillow suggested by Cyriax, we designed a new cervical pillow and compared the degree of pain reduction, quality of sleep and pillow satisfaction with a low hospital pillow and a high pillow. Method: The newly designed pillow has a built-in pressure-adjustable air bag in the cervical area and provides normal cervical lordotic curve in supine position and maintains cervical and thoracic vertebrae to form a horizontal line in side-lying position. Thiry-four patients with cervical pain used low hospital pillows for the first week of 3-week randomized crossover design study. They were subsequently randomly assigned to use each of the other two pillows for 1-week period. Outcomes were measured using Visual analog scale, Sleep questionaire, a pillow satisfaction scale. Result: Compared with other 2 types of pillow, Subjects using the newly desinged pillow showed much reduced pain intensity, increased duration of sleep and better satisfaction. Conclustion: We desinged a cervical pillow with built-in pressure adjustable air bag and it can significantly reduce pain intensity and improve quality of sleep in patients with cervical pain.

  • PDF

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.