• Title/Summary/Keyword: Lutz

Search Result 38, Processing Time 0.02 seconds

Analysis of Error Probability of Mobile Satellite Communication System In Korea Peninsula Area (한반도 지역에서 이동형 위성단말의 오류확률 분석)

  • Lee, Huikyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.67-71
    • /
    • 2019
  • In this paper, we derive a reference error probability performance in the environment where mobile satellite terminal is operated. When the satellite terminal moves, shadowing occurs due to the surrounding obstacles and the BER is lowered. We use the Lutz model simulating the environment in which mobile satellite terminals operate The Lutz model combines the Rician distribution with the Suzuki model. The error probability is derived from the numerical analysis of two distribution functions. The simulated results using the measured results in the Korean Peninsula forest area were similar to the BER results obtained using the Lutz model. Intuitively, the approximated results are similar to the measured results. Numerically, the BER error is about 3e-4 or less at an SNR of 30dB.

Isocenter Check and QA of Tactic Radiosurgery Devices Using EPID (EPID를 이용한 정위적방사선수술의 중심점 검사에 대한 연구)

  • Shin, Kyo Chul;Choi, Sang Gyu;Kim, Jung Kee;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.281-287
    • /
    • 2014
  • The Winston Lutz test, which checks the accuracy of the isocenter for stereotactic radiosurgery (SRS), was performed with the commercial electronic portal imaging device (EPID). The usual Winston Lutz test with film was also performed for comparison with the test with EPID. The maximum difference in isocenter between the two methods was 0.32 mm. The Winston Lutz test using EPID is practical as it can reduce time and avoid human errors compared to the test with film.

Determination of Crack Width and Crack Spacing in Reinforced Concrete Flexural Members (철근(鐵筋)콘크리트 휨부재의 균열폭 및 균열간격의 결정)

  • Kang, Young Jin;Oh, Byung Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.103-111
    • /
    • 1985
  • Presented is a study on the determination of crack width and crack spacing in the reinforced concrete flexural members. The derivation of crack width and crack spacing is based on the recently developed cracking theory. The new prediction formulas for the crack widths and crack spacings are proposed. An experiment for the reinforced concrete beams was conducted to compare with the proposed formulas. The comparisons of the present prediction formulas with our tests and other test data show good agreement. The present crack width formula has been also compared with the well-known ACI formula originally proposed by Gergely & Lutz. It was found that the present crack width formula shows better correlation with test data than that of Gergely & Lutz.

  • PDF

Navigating the Digital Maze - Pertinent Issues in E?Arbitration

  • Markert, Lars;Burghardt, Jan
    • Journal of Arbitration Studies
    • /
    • v.27 no.3
    • /
    • pp.3-31
    • /
    • 2017
  • Legal tech is commonly considered as the use of software and technology in the process of providing legal services. It is disrupting the method in which legal services are traditionally rendered, and under the buzz word "e-arbitration" also extends to the area of international commercial arbitration. This article aims to give an introduction into the most pertinent issues in "e-arbitration", starting with an attempt at defining the term "e-arbitration" and with an overview of some of the service providers. It goes on to address the use of information technology in international arbitration and concludes with an analysis of key legal issues arising when various aspects of the arbitral process are commenced, conducted or concluded in digital form.

A CLASSIFICATION RESULT AND CONTACT STRUCTURES IN ORIENTED CYCLIC 3-ORBIFOLDS

  • Ganguli, Saibal
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.1
    • /
    • pp.325-335
    • /
    • 2018
  • We prove every oriented compact cyclic 3-orbifold has a contact structure. There is another proof in the web by Daniel Herr in his uploaded thesis which depends on open book decompositions, ours is independent of that. We define overtwisted contact structures, tight contact structures and Lutz twist on oriented compact cyclic 3-orbifolds. We show that every contact structure in an oriented compact cyclic 3-orbifold contactified by our method is homotopic to an overtwisted structure with the overtwisted disc intersecting the singular locus of the orbifolds. In course of proving the above results we prove a classification result for compact oriented cyclic-3 orbifolds which has not been seen by us in literature before.

Evaluation of the Positional Accuracy of the Delivered Beams from the Target: A Phantom Study (방사선 치료에서 치료 표적과 조사 빔의 일치 정도 평가: 팬텀 연구)

  • Kang, Sei-Kwon;Cho, Byung-Chul;Cheong, Kwang-Ho;Ju, Ra-Hyeong;Kim, Su-Ssan;Kim, Kyoung-Ju;Choi, Sang-Gyu;Bae, Hoon-Sik;Lee, Re-Na;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.192-200
    • /
    • 2006
  • We evaluated the positional accuracy of the delivered beams to the target in a phantom by simulating the whole process of the radiation treatments Including CT scanning, planning and beam exposures with MLCs. For this purpose, a phantom was made to calibrate the alignment between the CT and the attached laser system. A new, convenient method was also devised to align the setup lasers in the treatment room. Film was used for the Identification of the delivered beam and analyzed with a homemade computer program. The positional differences between the target and the beam centers varied with the couch rotations. The accelerator we used showed a maximum discrepancy of 2.0 mm at the table angle of $295^{\circ}$. The same measurements based on the new isocenter from the Winston-Lutz test resulted in the maximum of 1.35 mm for all rotation angles. The evaluation of the differences between the target and the beam centers is useful for the treatment planning.

  • PDF