• Title/Summary/Keyword: Lung volume

Search Result 592, Processing Time 0.029 seconds

Video-Assisted Thoracoscopic Lung Volume Reduction Surgery in Severe Emphysema -A Case Report (폐기종 환자에서의 흉강내시경을 이용한 폐용적 감축술 -1례 보고-)

  • Lee, Du-Yeon;Jo, Hyeon-Min;Mun, Dong-Seok
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.827-832
    • /
    • 1997
  • Lung volume reduction surgery(LVRS) has recently been advocated as an alternative or a bridge to lung transplantation for patients with evere dibbling emphysema. This procedure is a palliative treatment performed to alleviate the dyspnea of patients with emphysema and improve performance in the activities of daily living. The rationale of lung volume reduction for generalized emphysema is that the removing of the diseased and functionless lung may improve the function of remaining, less diseased lung. The factors critical to the success of LVRS are careful patient selection, accurate localization of target areas, meticulous anesthetic and operative technique, and intensive postoperative support. We have experienced a case of severe emphysema in a 59-year-old male patient. After selection process and pulmonary rehabilitation, the patient was treated with video-assisted thoracoscopic LVRS and the post-operative course was uneventful.

  • PDF

Usefulness of Radiation Treatment Planning Applied Respiration Factor for Stereotactic Body Radiation Therapy in the Lung Cancer (폐암 환자의 정위체부방사선치료 시 호흡인자를 적용한 방사선 치료계획의 유용성)

  • Shin, Sung Pil;Kim, Tae-Hyung;So, Woon Young;Back, Geum Mun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.587-593
    • /
    • 2016
  • We are evaluated the usefulness of radiation treatment planning applied respiration factor for stereotactic body radiation therapy in the lung cancer. Four dimensional computed tomography images were obtained in 10 patients with lung cancer. The radiation treatment plans were established total lung volume according to respiration images (new method) and conventional method. We was analyzed in the lung volume, radiation absorbed dose of lung and main organs (ribs, tracheobronchus, esophagus, spinal cord) around the tumor, respectively. We were confirmed that lung volume and radiation absorbed dose of lung and main organs around the tumor deference according to applied respiration. In conclusion, radiation treatment planning applied respiration factor seems to be useful for stereotactic body radiation therapy in the lung cancer.

Evaluation of Platelet Indices in Lung Cancer Patients

  • Oncel, Mufide;Kiyici, Aysel;Oncel, Murat;Sunam, Guven Sadi;Sahin, Emel;Adam, Bahattin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7599-7602
    • /
    • 2015
  • Background: In this study, we aimed to determine platelet indices such as platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), Plateletcrit (PCT) platelet count (PLT) in lung cancer cases, and evaluate any relationships between these parameters and stage or histologic types. Materials and Methods: This retrospective study covered 44 lung cancer patients and 47 healthy subjects. Platelet indices including PLT, PCT, MPV, PDW were estimated and compared with normal subjects. The results were evaluated statistically. Results: The PDW value was significantly higher in the cancer group compared to the control group; however, the values for PCT and MPV were lower. Conclusions: We suggest potential use of platelet indices in diagnosis of lung cancer.

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.

Effects of Open or Closed Suctioning on Lung Dynamics and Hypoxemia in Mechanically Ventilated Patients (기관 내 흡인 유형이 인공호흡기 대상자의 폐기능과 저산소혈증에 미치는 효과)

  • Lee, Eun Young;Kim, Su Hyun
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: This study was conducted to compare effects of open and closed suctioning methods on lung dynamics (dynamic compliance, tidal volume, and airway resistance) and hypoxemia (oxygen saturation and heart rate) in mechanically ventilated patients. Methods: This study was a cross-over repeated design. Participants were 21 adult patients being treated with endotracheal intubation using a pressure-controlled ventilator below Fraction of Inspired Oxygen ($FiO_2$) 60% and PEEP $8cmH_2O$. Data were collected at baseline and 1, 2, 3, 4, 5, and 10 minutes after suctioning. Data were analyzed using two-factor ANOVA with repeated measures on time and suctioning type. Results: Effects of the interaction between suction type and time were significant for oxygen saturation and heart rate but not significant for dynamic compliance, tidal volume, or airway resistance. Prior to performance of suctioning, tidal volume and oxygen saturation were significantly lower, but airway pressure and heart rate were significantly higher using the closed suctioning method as compared with the open suctioning method. Conclusion: For patients on ventilator therapy below $FiO_2$ 60% and PEEP $8cmH_2O$, open suctioning performed after delivery of 100% $FiO_2$ using a mechanical ventilator may not have as much negative impact on lung dynamics and hypoxemia as closed suctioning.

Correlation between the Diaphragmatic Contraction Pressure and the Slow Vital Capacity

  • Lee, Jae-Seok;Han, Dong-Wook;Kang, Tae-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.47-53
    • /
    • 2019
  • PURPOSE: This study measured the external pressure on abdomen during maximal inspiration. The study determined the correlation between the diaphragmatic contraction pressure and the lung capacities to verify whether or not the measured pressure values can represent diaphragmatic contractility. METHODS: The study included 32 healthy subjects (16 males and 16 females). The researchers fabricated their own diaphragmatic pressure belt (DiP Belt) to measure DCP. DiP Belt device was fixed on the front of the abdomen and the diaphragmatic contractility was measured during maximal inspiration. The lung capacities were measured using a portable digital spirometer device (Pony Fx, COSMED, Italy). A digital spirometer is a device that is used to test the flow of air entering and exiting the lungs. RESULTS: DCP showed significant positive correlations with vital capacity (VC), inspiratory reserve volume (IRV) and inspiratory capacity (IC). Among values of lung capacities, IC showed especially strong positive correlations with the DCP (r =.714, p<.010). For the males, DCP showed significant positive correlations with IRV and IC, and DCP showed significant negative correlation with the expiratory reserve volume (ERV). For the females, DCP showed significant positive correlation with tidal volume (VT), but any significant correlation was not found with any of the other values of lung capacities. CONCLUSION: DCP showed high correlations with IRV and IC associated with inspiratory capacity. Therefore, The DiP Belt can be looked upon as a simple device that is very useful for measuring diaphragmatic contractility.

Larger Testicular Volume Is Independently Associated with Favorable Indices of Lung Function

  • Kim, Tae Beom;Park, I-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.4
    • /
    • pp.385-391
    • /
    • 2017
  • Background: Men with chronic obstructive pulmonary disease, have reduced endogenous testosterone levels, but the relationship between pulmonary function and endogenous testosterone levels, is inconsistent. Testicular volume is a known indicator of endogenous testosterone levels, male fertility, and male potency. In the present study, the authors investigated the relationship, between testicular volume and lung function. Methods: One hundred and eighty-one South Korean men age 40-70, hospitalized for urological surgery, were retrospectively enrolled, irrespective of the presence of respiratory disease. Study subjects underwent pulmonary function testing, prior to procedures, and testicular volumes were measured by orchidometry. Testosterone levels of patients in blood samples collected between $7{\small{AM}}$ and $11{\small{AM}}$, were measured by a direct chemiluminescent immunoassay. Results: The 181 study subjects were divided into two groups, by testicular volume (${\geq}35mL$ vs. <35 mL), the larger testes group, had better lung functions (forced vital capacity [FVC]: $3.87{\pm}0.65L$ vs. $3.66{\pm}0.65L$, p=0.037; forced expiratory volume in 1 second [$FEV_1$]: $2.92{\pm}0.57L$ vs. $2.65{\pm}0.61L$, p=0.002; FVC % predicted: $98.2{\pm}15.2%$ vs. $93.8{\pm}13.1%$, p=0.040; $FEV_1$ % predicted: $105.4{\pm}19.5%$ vs. $95.9{\pm}21.2%$, p=0.002). In addition, the proportion of patients with a $FEV_1/FVC$ of <70%, was lower in the larger testes group. Univariate analysis conducted using linear regression models, revealed that testicular volume was correlated with FVC (r=0.162, p=0.029), $FEV_1$ (r=0.218, p=0.003), $FEV_1/FVC$ (r=0.149, p=0.046), and $FEV_1$ % predicted (r=0.178, p=0.017), and multivariate analysis using linear regression models, revealed that testicular volume was a significant predictive factor for $FEV_1$ % predicted (${\beta}=0.159$, p=0.041). Conclusion: Larger testicular volume was independently associated, with favorable indices of lung function. These results suggest that androgens, may contribute to better lung function.

Volume and Mass Doubling Time of Lung Adenocarcinoma according to WHO Histologic Classification

  • Jung Hee Hong;Samina Park;Hyungjin Kim;Jin Mo Goo;In Kyu Park;Chang Hyun Kang;Young Tae Kim;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.464-475
    • /
    • 2021
  • Objective: This study aimed to evaluate the tumor doubling time of invasive lung adenocarcinoma according to the International Association of the Study for Lung Cancer (IASLC)/American Thoracic Society (ATS)/European Respiratory Society (ERS) histologic classification. Materials and Methods: Among the 2905 patients with surgically resected lung adenocarcinoma, we retrospectively included 172 patients (mean age, 65.6 ± 9.0 years) who had paired thin-section non-contrast chest computed tomography (CT) scans at least 84 days apart with the same CT parameters, along with 10 patients with squamous cell carcinoma (mean age, 70.9 ± 7.4 years) for comparison. Three-dimensional semiautomatic segmentation of nodules was performed to calculate the volume doubling time (VDT), mass doubling time (MDT), and specific growth rate (SGR) of volume and mass. Multivariate linear regression, one-way analysis of variance, and receiver operating characteristic curve analyses were performed. Results: The median VDT and MDT of lung cancers were as follows: acinar, 603.2 and 639.5 days; lepidic, 1140.6 and 970.1 days; solid/micropapillary, 232.7 and 221.8 days; papillary, 599.0 and 624.3 days; invasive mucinous, 440.7 and 438.2 days; and squamous cell carcinoma, 149.1 and 146.1 days, respectively. The adjusted SGR of volume and mass of the solid-/micropapillary-predominant subtypes were significantly shorter than those of the acinar-, lepidic-, and papillary-predominant subtypes. The histologic subtype was independently associated with tumor doubling time. A VDT of 465.2 days and an MDT of 437.5 days yielded areas under the curve of 0.791 and 0.795, respectively, for distinguishing solid-/micropapillary-predominant subtypes from other subtypes of lung adenocarcinoma. Conclusion: The tumor doubling time of invasive lung adenocarcinoma differed according to the IASCL/ATS/ERS histologic classification.

Comparison and Evaluation of the Effectiveness between Respiratory Gating Method Applying The Flow Mode and Additional Gated Method in PET/CT Scanning. (PET/CT 검사에서 Flow mode를 적용한 Respiratory Gating Method 촬영과 추가 Gating 촬영의 비교 및 유용성 평가)

  • Jang, Donghoon;Kim, Kyunghun;Lee, Jinhyung;Cho, Hyunduk;Park, Sohyun;Park, Youngjae;Lee, Inwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.54-59
    • /
    • 2017
  • Purpose The present study aimed at assessing the effectiveness of the respiratory gating method used in the flow mode and additional localized respiratory-gated imaging, which differs from the step and go method. Materials and Methods Respiratory gated imaging was performed in the flow mode to twenty patients with lung cancer (10 patients with stable signals and 10 patients with unstable signals), who underwent PET/CT scanning of the torso using Biograph mCT Flow PET/CT at Bundang Seoul University Hospital from June 2016 to September 2016. Additional images of the lungs were obtained by using the respiratory gating method. SUVmax, SUVmean, and Tumor Volume ($cm^3$) of non-gating images, gating images, and additional lung gating images were found with Syngo,bia (Siemens, Germany). A paired t-test was performed with GraphPad Prism6, and changes in the width of the amplitude range were compared between the two types of gating images. Results The following results were obtained from all patients when the respiratory gating method was applied: $SUV_{max}=9.43{\pm}3.93$, $SUV_{mean}=1.77{\pm}0.89$, and $Tumor\;Volume=4.17{\pm}2.41$ for the non-gating images, $SUV_{max}=10.08{\pm}4.07$, $SUV_{mean}=1.75{\pm}0.81$, and $Tumor\;Volume=3.56{\pm}2.11$ for the gating images, and $SUV_{max}=10.86{\pm}4.36$, $SUV_{mean}=1.77{\pm}0.85$, $Tumor\;Volume=3.36{\pm}1.98$ for the additional lung gating images. No statistically significant difference in the values of $SUV_{mean}$ was found between the non-gating and gating images, and between the gating and lung gating images (P>0.05). A significant difference in the values of $SUV_{max}$ and Tumor Volume were found between the aforementioned groups (P<0.05). The width of the amplitude range was smaller for lung gating images than gating images for 12 from 20 patients (3 patients with stable signals, 9 patients with unstable signals). Conclusion In PET/CT scanning using the respiratory gating method in the flow mode, any lesion movements caused by respiration were adjusted; therefore, more accurate measurements of $SUV_{max}$, and Tumor Volume could be obtained from the gating images than the non-gating images in this study. In addition, the width of the amplitude range decreased according to the stability of respiration to a more significant degree in the additional lung gating images than the gating images. We found that gating images provide information that is more useful for diagnosis than the one provided by non-gating images. For patients with irregular signals, it may be helpful to perform localized scanning additionally if time allows.

  • PDF