• 제목/요약/키워드: Lung CT

검색결과 856건 처리시간 0.03초

Bronchus-Associated Lymphoid Tissue (BALT) Lymphoma of the Lung Showing Mosaic Pattern of Inhomogeneous Attenuation on Thin-section CT: A Case Report

  • In-Jae Lee;Sung Hwan Kim;Soo Hyun Koo;Hyun Beom Kim;Dae Hyun Hwang;Kwan Seop Lee;Yul Lee;Kee Taek Jang;Duck-Hwan Kim
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.159-161
    • /
    • 2000
  • The authors present a case of histologically proven bronchus-associated lymphoid tissue (BALT) lymphoma of the lung in a patient with primary Sjögren's syndrome that manifested on thin-section CT scan as a mosaic pattern of inhomogeneous attenuation due to mixed small airway and infiltrative abnormalities

  • PDF

Lung Cancer의 Stereotactic Radiosurgery시 Respiratory Gating system의 유용성에 대한 연구 (Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer)

  • 송흥권;김민수;양오남;박철수;권경태;김정만
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.13-17
    • /
    • 2005
  • Lung cancer 환자 중 호흡에 의한 종양의 움직임이 큰 lung lower lobe에서 stetreotactic radiosurgery(SRS)시 호흡 주기 중 종양의 움직임이 적은 호흡 주기에서만 방사선을 조사하기 위해 respiratory gating system을 사용함으로써 그 유용성에 대하여 알아보고자 한다. lung lower lobe의 SRS 환자 2명을 대강으로 하였으며, 환자의 복부에 maker block(sensor)을 부착하고 tracking camera와 real time position management(RPM)를 이용하여 호흡 주기를 측정하면서 1회 호흡주기에서 10 phases의 4D-CT를 촬영 하였다. 종양의 위치 변화가 급격하지 않은 percent($\%$)의 phases를 치료 phases로 결정하였고, 치료 phases의 CT image를 maximum intensity projection(MIP) 기법으로 재구성 후 volume contouring을 하였다. set up 의 재현성 및 GTV의 위치 변화를 확인하기 위해 치료 전과 치료 중 2회의 4D-CT 촬영을 하였다. GTV의 움직임이 가장 큰 Y(longitudinal)축에서 A환자 full($0\%\~90\%$) phases의 9.4mm가 치료 ($30\%\~60\%$) phases 에서는 2.6mm로, B환자 full($0\%\~90\%$) phases의 11.7mm가 치료($30\%\~70\%$) phases 에서는 2.3mm로 줄었다. 2회의 4D-CT 비교 결과 Set up의 X, Y, Z축 오차는 모두 3mm 이내였다. 호흡에 의한 종양의 움직임이 큰 lung lower lobe에서 SRS 시행 시 respiratory gating system의 사용은 종양의 움직임을 5mm 이내로 감소시킬 수 있어 유용하였다.

  • PDF

정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가 (Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs)

  • 최호정;이기자;최수영;이정우;한우석;이인;권영항;이영원
    • 한국임상수의학회지
    • /
    • 제28권5호
    • /
    • pp.510-515
    • /
    • 2011
  • 개에서 컴퓨터단층촬영술을 이용하여, 촬영 자세에 따른 정상 폐의 용적과 밀도를 정량적으로 평가하였다. 각각 6 마리의 페키니즈견과 말티즈견에서 컴퓨터단층촬영을 실시하면서 자세를 앙와위, 좌측과 우측 횡와위, 그리고 흉와위로 변경하였다. 컴퓨터단층촬영을 실시하는 동안 일정한 정도의 양압환기를 실시하였다. 폐용적과 밀도는 CT 영상의 삼차원 재구성 방식을 통해 측정하였고, 전체 폐용적 및 밀도, 좌측과 우측 폐의 용적과 밀도를 각각 측정하였다. 삼차원 재구성 결과 폐의 모양은 두 품종견에서 매우 다르게 나타났다. 폐용적과 밀도는 촬영 자세를 변경하는 동안 두 품종견에서 모두 유의적인 변화를 보이지 않았다. 오른쪽 폐용적이 왼쪽 폐에 비해 유의적으로 약 $66.91{\pm}25.1$ ml 만큼 컸다. 페키니즈 견과 말티즈 견의 체중 차이가 유의적이었으며, 체중과 흉와위로 촬영한 폐용적 간에 선형관계가 관찰되었다. 좌우측 횡와위 촬영에서 중력의 영향을 받는 쪽의 폐는 반대쪽 폐에 비해 밀도는 높고 용적은 감소되었다. 컴퓨터단층촬영으로 측정한 전체 폐용적은 폐밀도와 관련이 있었으며, 폐밀도가 정상 폐용적을 유추하는데 유용하게 사용될 것으로 생각된다.

ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰 (A study of usefulness for the plan based on only MRI using ViewRay MRIdian system)

  • 전창우;이호진;안범석;김찬용;이제희
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.131-143
    • /
    • 2015
  • 목 적 : MRI를 기반으로 한 CT fusion plan과 MRI only based plan을 비교함으로써 MRI only plan의 유용성을 평가하고, 나아가 Simulation과 치료계획을 포함한 방사선치료의 전 과정을 CT 촬영 없이 MRI 영상으로 구성하여 실시간 MR-IGRT를 구현하고자 한다. 대상 및 방법 : 본원에서 사용중인 BBB CT (Brilliance Big Bore CT, 16slice, Philips)와 Viewray MRIdian System (Viewray, USA)으로 환자 11명(Head and Neck 1명, Breast 5명, Lung 1명, Liver 3명, Prostate 1명)을 대상으로 CT & MR simulation 및 치료계획을 세웠다. Head and Neck, Breast, Prostate환자는 자유호흡(Free Breathing) 상태로, Lung과 Liver 환자는 흡기 호흡중지(Inhalation Breathing Holdng)상태로 Simulation을 진행하였다. Viewray의 Bore 크기 및 Coil 위치를 고려하여 환자 자세 및 고정기구를 동일한 조건을 유지하여 CT simulation을 시행하였다. Viewray MRIdian 시스템을 이용하여 MR 영상을 기반으로 한 CT fusion plan과 CT fusion 없이 [ICRU 46]에서 권고하는 폐, 공기, 뼈의 전자밀도를 입력한 동일한 조건의 MR only plan을 세웠다. Head and Neck, Breast, Prostate는 IMRT, Lung과 Liver 는 Gating치료계획을 세웠고, 치료계획의 평가는 PTV의 균질성 지표 (Homogeneity Index, HI)와 일치성 지표 (Conformity Index, CI), 그리고 각 PTV와 OAR의 DVH와 선량차이를 각각 비교하였다. 결 과 : 두 치료계획간 치료부위별 PTV에 대한 HI 값의 차이는 Head and Neck, Breast, Lung, Liver, Prostate 부위별로 각각 0.089, 0.26, 0.67, 0.2, 0.4%로 나타났으며, CI 값의 차이는 부위별로 각각 0.043, 0.84, 0.68, 0.46, 0.3%로 두가지 평가 값 모두 Head and Neck 부위가 가장 작은 차이를 나타냈다. PTV에 대한 평균선량 차이는 치료부위별로 각각 0.07, 0.29, 0.18, 0.3, 0.18 Gy로 나타났다. 이를 백분율로 나타냈을 때 0.06, 0.7, 0.29, 0.69, 0.44%으로 모두 1% 이하의 차이를 보였다. 두경부암의 각 OAR은 전체적으로 0.01~0.12 Gy의 평균선량 차이를 보였으며, 유방암은 0.04~0.06 Gy, 폐암에서는 0.01~0.21 Gy, 간암은 0.06~0.27 Gy, 전립선암은 0.02~0.23 Gy의 평균선량 차이를 나타냈다. 결 론 : MR 영상을 이용한 치료계획은 연부조직에서 탁월한 대조도를 나타낼 뿐만 아니라 CT fusion한 MR 치료계획과 비교했을 때 PTV의 HI, CI, 선량차이 모두 1%미만의 차이를 보였으며, OAR의 경우 비균질한 조직이 많은 부위일수록 최대 0.89 Gy 선량차이를 보였다. 이결과를 토대로 두경부암, 부분적 유방암이나 전립선암등 비균질도 차이가 적은 부위에는 CT촬영 없이 MR 영상만을 이용한 방사선치료의 가능성을 확인 할 수 있었다.

  • PDF

흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究) (Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques)

  • 이주혁;고경환;하성환;한만청
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

Imaging Features of Lung Lobe Torsion in Two Dogs with Typical or Atypical Initial Radiographic Signs

  • Jeong, Sulhwa;Seo, Jeongim;Lee, Jinmin;Chang, HwaSeok;Choi, Mincheol;Yoon, Junghee
    • 한국임상수의학회지
    • /
    • 제35권6호
    • /
    • pp.282-285
    • /
    • 2018
  • A 7 years old, male, Afghan hound (case 1) and a 10 years old, castrated male, Pekingese (case 2) were referred with dyspnea. In case 1, thoracic radiographs showed moderate amount of pleural effusion and lobar sign in the left cranial lung lobe. Following computed tomographic (CT) examination, lung lobe torsion in left cranial lung lobe was diagnosed. In case 2, thoracic radiographs showed increased cranial lobar opacity but there was no evidence of pleural effusion. CT examination revealed an abrupt ending bronchus in the left cranial lung lobe. Based on the imaging diagnosis, left cranial lung lobectomy was performed in both cases. Case 1 showed increased lobar opacity and pleural effusion, while case 2 just showed less concrete evidence of lung lobe torsion on thoracic radiographs and marked severe chronic suppurative pneumonia was histopathologically confirmed. In conclusion, CT could be an important modality when atypical lung disease is suspicious.

Cystic Lung Disease: a Comparison of Cystic Size, as Seen on Expiratory and Inspiratory HRCT Scans

  • Ki-Nam Lee;Seong-Kuk Yoon;Seok Jin Choi;Jin Mo Goo;Kyung-Jin Nam
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.84-90
    • /
    • 2000
  • Objective: To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. Materials and Methods: The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. Results: All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. Conclusion: In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  • PDF

폐암의 조직학적 분류에 따른 종양의 FDG 섭취와 CT 조영증강정도에 관한 연구 (FDG Uptake and a Contrast Enhancement According to Histopathologic Types in Lung Cancers)

  • 한유미;최재걸;김영철;박은경
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.19-25
    • /
    • 2009
  • 목적: 폐암에서 양전자단층촬영(PET-CT)에서의 2[F-18]-fluoro-2-deoxy-d-glucose (FDG)의 최대 표준화섭취(SUVmax)와 전산화단층찰영(CT)에서의 조영증장정도에 서로 연관성이 있는지를 알아보고 SUVmax와 조영증강 정도에 있어 폐암의 조직학적 유형간에 유의한 차이가 있는지를 평가 하고자 하였다. 대상 및 방법: PET-CT와 조영증강 흥부 CT를 시행하고 조직학적으로 원발성 폐암으로 확진된 환자 53명을 대상으로 하였다. 초기 및 지연 PET-CT영상에서의 종양의 SUVmax (SUV1, SUV2), 지연영상에서의 SUVmax의 증가정도(SUVd), 잔류지수(RI) 및 종양의 CT 조영증강정도를 측정하고 상관관계를 알아보았으며, 이 변수들의 폐암의 조직학적 유형에 따른 차이와 종양내부에서 차이를 평가하였다. 결과: 평균값과 표준 편차는 SUV1이 $8.3{\pm}4.4$, SUV2가 $10.7{\pm}5.7$, SUVd가 $2.4{\pm}1.6$, RI가 $30{\pm}14$, 조영증강정도가 $47.1{\pm}14.8$ HU (Hounsfield Unit)이었다. 조직학적 유형 간 SUV1과 조영증강정도에는 차이가 없었다. SUV1과 SUVd 사이에는 r=0.74(p<0.01), SUV1과 종양의 크기 사이에는 r=0.58 (p<0.01)로 유의한 상관관계가 있었고 SUV1과 조영증강정도 사이에는 상관관계가 없었다(r=0.06, p=0.69). 같은 종양 내부에서 최대 FDG 섭취부위와 최대 조영증강부위가 일치하지 않는 경우가 10예 있었다. 결론: 폐암에서의 FDG 섭취정도와 CT 조영증강정도는 서로 유의한 양적인 선형 상관관계를 보이지 않았으며 조직학적 분류에 따른 FDG 섭취나 조영증강정도의 차이도 없었다.

An Effective WSSENet-Based Similarity Retrieval Method of Large Lung CT Image Databases

  • Zhuang, Yi;Chen, Shuai;Jiang, Nan;Hu, Hua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권7호
    • /
    • pp.2359-2376
    • /
    • 2022
  • With the exponential growth of medical image big data represented by high-resolution CT images(CTI), the high-resolution CTI data is of great importance for clinical research and diagnosis. The paper takes lung CTI as an example to study. Retrieving answer CTIs similar to the input one from the large-scale lung CTI database can effectively assist physicians to diagnose. Compared with the conventional content-based image retrieval(CBIR) methods, the CBIR for lung CTIs demands higher retrieval accuracy in both the contour shape and the internal details of the organ. In traditional supervised deep learning networks, the learning of the network relies on the labeling of CTIs which is a very time-consuming task. To address this issue, the paper proposes a Weakly Supervised Similarity Evaluation Network (WSSENet) for efficiently support similarity analysis of lung CTIs. We conducted extensive experiments to verify the effectiveness of the WSSENet based on which the CBIR is performed.

"S" modifier를 이용한 저선량 CT의 폐암 외 중요 소견에 대한 민감도 분석 (Sensitivity Analysis of Critical Findings Other than Lung Cancer in Low-Dose CT Using "S" Modifier)

  • 김현진
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.343-350
    • /
    • 2023
  • 본 연구에서는 2016년 11월부터 폐암 검진 판독 시 판독의 표준화를 위하여 사용되고 있는 Lung-RADS (Lung CT Screening Reporting and Data System)에 기반하여 폐암 이외에 부수적으로 발견되는 "S" modifier 소견들의 종류와 빈도를 분석하고자 하며 이를 통하여 저선량 CT를 통해 얻을 수 있는 폐암 외의 중요 소견들에 대해 살펴보고 저선량 CT의 폐암 외 질환에 대한 유용성을 파악하고자 하였다. 본 연구 결과 전체 1023명의 대상자에서 360건(35.19%)의 "S" modifier 소견이 나타났으며 가장 발생빈도가 높은 질환은 관상동맥 석회화와 폐기종으로 관상동맥 석회화는 145건(14.17%), 폐기종은 138건(13.49%)으로 나타나 다른 소견들에 비해 발견 비율이 매우 높음을 알 수 있다. 또한 흡연 기간과 연관성이 매우 높은 것으로 확인되었는데 관상동맥 석회화의 경우 비흡연자인 A 그룹에서는 발견 비율이 9건(5.73%), 흡연 10년 이내의 B그룹은 23건(11.44%), 흡연 20년 이내의 C 그룹은 39건(13.68%), 흡연 30년 이내의 D그룹은 43건(18.53%), 흡연 30년 이상의 E그룹은 31건(20.94%)로 나타나 흡연력이 증가할수록 관상동맥 석회화의 발생 확률이 증가함을 알 수 있다. 관상동맥 석회화와 폐기종 이외에도 폐렴 및 폐 간질의 이상소견, 종격동 질환도 흡연 기간과의 연관성 분석결과 p<0.05로 나타나 흡연 기간에 영향을 받음을 알 수 있다.