• Title/Summary/Keyword: Luminous color

Search Result 164, Processing Time 0.027 seconds

The Optical Characteristics of 240 W High Power LED Fish Luring Lamp (240W급 고출력 LED 집어등의 광학적 특성)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Sang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.681-687
    • /
    • 2013
  • This study analyzed characteristics of 240 W high power LED lamps by comparing with those of traditional metal halide lamps. In addition, it analyzed the propriety of LED lamps as a source of light, considering seawater transmission characteristics. When Applying white LED package with the color temperature color temperature of 6500K, a 240W-LED fishing lamp has a characteristics of the luminous angle to be expanded to ${\pm}45^{\circ}$, the illumination change was improved to 0.8, as well as the luminance efficiency was improved to 98.8lm/W. As results of comparison between one 1,500W-metal halide lamp and four 240W-LED lamp with considering a seawater transmission and a luminous efficiency of scotopic vision, the radiant flux of two lamps were almost equal level at 50m depth and the luminous flux was 5% higher LED lamp than metal-halide lamp even if only applying the luminous efficiency of scotopic vision. As the luminous flux of LED lmap was 14% higher than that of metal-halide lamp with applying the luminous efficiency of scotopic vision to radiant flux at 50m depth, so LED fishing lamp was verified to alternative possibility of metal-halide lamp.

Physical Measurement of Color Changes in Foods (식품(食品)의 색도변화(色度變化) 측정법(測定法))

  • Cho, Sung-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 1984
  • The tools and techniques for measuring the spectral distribution of light emitted by, transmitted by, or reflected from food surfaces are described for determining the extent to which original natural color is preserved in processing and subsequent storage of foods. Color differences may be evaluated indirectly in terms of some physical characteristic of the sample or extracted fraction thereof that is largely responsible for the color characteristics. For evaluation more directly in terms of what the observer actually seen, color differences are measured by reflectance spectrophotometry and photoelectric colorimetry and expressed as differences in psychophysical indexes such as luminous reflectance and chromaticity. The standard system, against which other systems could be compared, is the one recommended by the International Committee on illumination and which is based on the 'standard observer', which is a simulated standard eye, consisting of three primary color filters Z, with X being essentially amber in color, Y, green and Z, blue. Any spectrophotometric curve of reflectance obtained from the surface of an object can be integrated in terms of X, Y and Z. Psychophysical notation may be converted by standard methods to the colorimetrically more descriptive terms of Munsell hue, value and chroma.

  • PDF

Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries (미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석)

  • Park, Yoon-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

Research and Development of High Luminous Efficacy Plasma Displays

  • Kosugi, Naoki;Akiyama, Toshiyuki;Kitagawa, Masatoshi;Shinodaq, Tsutae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • Over 5lm/W white luminous efficacy was obtained by 11" color test panel with narrowed discharge electrodes combined with high Xe partial pressure. By using optical spectroscopic methods, it was suggested that the electron heating efficiency is the most significant to improve the plasma efficiency in our experimental conditions.

  • PDF

IDENTIFICATION OF LUMINOUS WHITE DWARF CANDIDATES IN THE GLOBULAR CLUSTERS M13 AND M22 USING HST ACS PHOTOMETRIC DATA

  • CHO, DONG-HWAN;YOON, TAE SEOG;LEE, SANG-GAK;SUNG, HYUN-IL
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.265-266
    • /
    • 2015
  • A search for luminous white dwarfs (WDs) in several nearby Galactic globular clusters (GCs) was carried out using the deep and homogeneous photometric catalog of Galactic GCs taken with the ACS/WFC aboard the Hubble Space Telescope (HST) by Sarajedini et al. and Anderson et al- It resulted in the identification of luminous WD candidates in the GCs M13 (NGC 6205) and M22 (NGC 6656). The purpose of the present study is to identify luminous WDs in the deep and homogeneous V versus V - I color-magnitude diagrams (CMDs) of several nearby Galactic GCs taken with the ACS/WFC aboard the HST. Using photometric data for the GCs M13 and M22 that are now in the public domain, the V versus V - I CMDs of the GCs M13 and M22 were constructed. Many spurious detections in the CMDs were removed using the photometric quality parameters qfit(V) and qfit(I), and a radial restriction was applied to the CMDs to remove the central stars with higher photometric errors due to central crowding. From each resultant V versus V - I CMD of the GCs M13 and M22, a dozen or so luminous WD candidates were identified. They were confirmed as stellar objects in the accompanying ACS/WFC images and their positions in the CMDs were in the bright part of the DA WD cooling curve. Therefore, the luminous WD candidates in the GCs M13 and M22 seem to be true luminous WDs, and spectroscopic observations are needed to confirm their true identity.

Mechanism of High Luminous Efficiency in Delta Color Arrayed, Enclosed Sub-pixel Structured AC PDP with High Xe Content

  • Bae, Hyun-Sook;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.59-62
    • /
    • 2004
  • We investigated the effect of Xe content variation on the luminous efficiency of two different sub-pixel types, i.e., segmented electrode in delta color arrayed enclosed sub-pixel (SDE) and conventional stripe barrier type, in an ac plasma display panel through three-dimensional numerical simulations. The conventional cell type was found to have higher VUV generation efficiency as compared with that of SDE structure, but as the Xe content increased, the SDE type showed higher improvements in efficiency due to the lower plasma loss to the barrier walls.

  • PDF

Efficient White Organic Light-Emitting Diodes (WOLEDs) with Device Structure Modification

  • Kim, Jun-Ho;Seo, Ji-Hoon;Seo, Ji-Hyun;Hyung, Gun-Woo;Lee, Kum-Hee;Yoon, Seoung-Soo;Kim, Young-Kwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1403-1406
    • /
    • 2007
  • An effective WOLED structure was demonstrated which improved a luminous efficiency and white color chromaticity independent on applied bias by employing effective carrier transporting layer, without any alteration of emissive materials. The modified WOLEDs exhibited 2 times higher luminous efficiency than the control device and showed balanced white emission during an operation.

  • PDF

Development of Basking Neodymium Lamp Improving Reflector Globe and Rhenium Filament (레늄 필라멘트와 반사 글로브를 개선한 Basking Neodymium Lamp의 개발)

  • Eo, Ik-Soo;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.477-482
    • /
    • 2007
  • This paper examines and analyzes improvement of structure of bulb, increase of luminous efficiency through application of reflector globe through aluminum coating and development of 60[W] basking neodymium lamp through optimum insertion ratio of krypton gas and nitrogen gas. The results of this development shows that the life of the lamp was 7,200 hours, and the luminous flux was 620[1m]. This brings in superior color temperature and superior color rendering index, which allows us to use that lamp for agricultural or general purpose.

  • PDF

Properties of high efficiency 2-${\lambda}$ white organic light emitting diode (고 효율 2파장 백색 유기 발광 소자의 발광 특성)

  • Lee, Oun-Gyu;Oh, Young-Jun;Ko, Young-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.324-325
    • /
    • 2006
  • In order to develop high efficiency white organic light-emitting diodes (OLEDs), OLED devices consisted of red and blue emitting layers (EMLs) were fabricated and the effect of respective layer thickness and the order of layer stacking on the luminous efficiency was evaluated Red/blue structure showed higher efficiency than blue/red, due to the higher exiton formation. In the blue layer of red/blue structure. However, the efficiency of the red/blue significantly depended on the thickness of the red layer, whereas the thickness of the blue layer was not affect so much. The optimum thickness of the red layer was 20 ${\AA}$, where the luminous and power efficiencies were 155 cd/A and 10.51 lm/W at 1000~3000$cd/m^2$ respectively and the maximum luminance was about 80,000 $cd/m^2$.

  • PDF